manual: link to new common cs7-config.adoc, remove some dup of that
Related: OS#2767 Depends: Ia2508d4c7b0fef9cdc57e7e122799a480e340bf7 (osmo-gsm-manuals) Change-Id: Ie88dd2c7f7318a31ae04fbd6930346d92141fde5
This commit is contained in:
parent
92b0246301
commit
346a3b956f
|
@ -0,0 +1,10 @@
|
||||||
|
# When cleaning up this file: bump API version in corresponding Makefile.am and rename corresponding debian/lib*.install
|
||||||
|
# according to https://www.gnu.org/software/libtool/manual/html_node/Updating-version-info.html#Updating-version-info
|
||||||
|
# In short:
|
||||||
|
# LIBVERSION=c:r:a
|
||||||
|
# If the library source code has changed at all since the last update, then increment revision: c:r + 1:a.
|
||||||
|
# If any interfaces have been added, removed, or changed since the last update: c + 1:0:0.
|
||||||
|
# If any interfaces have been added since the last public release: c:r:a + 1.
|
||||||
|
# If any interfaces have been removed or changed since the last public release: c:r:0.
|
||||||
|
#library what description / commit summary line
|
||||||
|
manual needs common chapter cs7-config.adoc from osmo-gsm-manuals > 0.3.0
|
|
@ -107,20 +107,21 @@ running on the same interface:
|
||||||
|
|
||||||
==== Configure SCCP/M3UA to accept _A_ and _IuCS_ links
|
==== Configure SCCP/M3UA to accept _A_ and _IuCS_ links
|
||||||
|
|
||||||
OsmoMSC will contact an STP instance to establish an SCCP/M3UA link. BSC and
|
OsmoMSC acts as client to contact an STP instance and establish an SCCP/M3UA
|
||||||
HNBGW will then reach the MSC via this link. By default, an STP instance is
|
link.
|
||||||
assumed to listen on the default M3UA port (2905) on the local host.
|
|
||||||
|
|
||||||
Establishing an SCCP/M3UA link towards an STP instance not on the local host
|
An example configuration of OsmoMSC's SCCP link:
|
||||||
can be configured as follows:
|
|
||||||
|
|
||||||
----
|
----
|
||||||
cs7 instance 0
|
cs7 instance 0
|
||||||
asp my-OsmoMSC 2905 0 m3ua
|
point-code 0.23.1
|
||||||
! IP address of the remote STP:
|
asp asp-clnt-OsmoMSC-A-Iu 2905 0 m3ua
|
||||||
remote-ip 10.23.24.1
|
remote-ip 127.0.0.1
|
||||||
|
sctp-role client
|
||||||
----
|
----
|
||||||
|
|
||||||
|
This configuration is explained in detail in <<cs7_config>>.
|
||||||
|
|
||||||
Note that _A_ and _IuCS_ may use different SCCP instances, if so desired:
|
Note that _A_ and _IuCS_ may use different SCCP instances, if so desired:
|
||||||
|
|
||||||
----
|
----
|
||||||
|
@ -135,21 +136,6 @@ msc
|
||||||
cs7-instance-iu 1
|
cs7-instance-iu 1
|
||||||
----
|
----
|
||||||
|
|
||||||
A full configuration needs an `asp` on an `as` -- an Application Server Process
|
|
||||||
running on an Application Server -- as well as a local point code and routing
|
|
||||||
configuration. The SCCP VTY automatically creates those parts that are missing,
|
|
||||||
by assuming sane defaults. A complete configuration would look like this:
|
|
||||||
|
|
||||||
----
|
|
||||||
cs7 instance 0
|
|
||||||
point-code 0.23.1
|
|
||||||
asp my-OsmoMSC-A-Iu 2905 0 m3ua
|
|
||||||
remote-ip 127.0.0.1
|
|
||||||
as my-as-for-OsmoMSC-A-Iu m3ua
|
|
||||||
asp my-OsmoMSC-A-Iu
|
|
||||||
routing-key 0 0.23.1
|
|
||||||
----
|
|
||||||
|
|
||||||
==== Configure GSUP to reach the HLR
|
==== Configure GSUP to reach the HLR
|
||||||
|
|
||||||
OsmoMSC will assume a GSUP server (OsmoHLR) to run on the local host and the
|
OsmoMSC will assume a GSUP server (OsmoHLR) to run on the local host and the
|
||||||
|
|
|
@ -22,6 +22,8 @@ include::./common/chapters/vty.adoc[]
|
||||||
|
|
||||||
include::./common/chapters/logging.adoc[]
|
include::./common/chapters/logging.adoc[]
|
||||||
|
|
||||||
|
include::./common/chapters/cs7-config.adoc[]
|
||||||
|
|
||||||
include::{srcdir}/chapters/net.adoc[]
|
include::{srcdir}/chapters/net.adoc[]
|
||||||
|
|
||||||
include::./common/chapters/smpp.adoc[]
|
include::./common/chapters/smpp.adoc[]
|
||||||
|
|
Loading…
Reference in New Issue