manuals: add section about the SGs interface.
The SGs interface is currently only casually mentioned in the chapter running, even though the SGs interface is a prominent and often requested feature. Let's give the SGs interface its own section so that users can find the info about it quicker. Related: OS#6008 Change-Id: Ic7c17511ee19cb7f6d5069b27beb661ecb4b0be8
This commit is contained in:
parent
656354b818
commit
1759ed5709
|
@ -74,15 +74,8 @@ msc
|
|||
|
||||
More on MNCC in <<mncc-external>>.
|
||||
|
||||
The SGs interface by default listens on 0.0.0.0:29118. Configure a different IP and/or port for each osmo-msc instance.
|
||||
You may also want to configure different VLR names:
|
||||
|
||||
----
|
||||
sgs
|
||||
local-ip 127.0.0.1
|
||||
local-port 29118
|
||||
vlr-name vlr.example.net
|
||||
----
|
||||
The SGs interface by default listens on 0.0.0.0:29118 (SCTP). Each instance of OsmoMSC must use a different IP address
|
||||
and/or port. For details about the configuration of the SGs interface, see section <<sgs>>.
|
||||
|
||||
For the following links, OsmoMSC acts as a client and does not listen/bind to a
|
||||
specific interface, and will hence not encounter conflicts for multiple instances
|
||||
|
|
|
@ -0,0 +1,55 @@
|
|||
[[sgs]]
|
||||
== SGs interface
|
||||
|
||||
OsmoMSC offers an SGs interface using the SGsAP protocol. The SGs interface is an
|
||||
optional interface between a 2G (GERAN) / 3G (UTRAN) MSC and an 4G (EUTRAN) MME.
|
||||
Its purpose is to facilitate both CSFB (Circuit-Switched Fall Back) and SMSoS
|
||||
(SMS over SGs). It is used for Mobility management (MM) and paging procedures
|
||||
between the EPS (Evolved Packet Services) and CS (Circuit Switched) domain.
|
||||
|
||||
=== VTY configuration
|
||||
|
||||
The SGs interface implementation in OsmoMSC is automatically active and requires
|
||||
only minimal configuration. When no specific configuration is provided OsmoMSC
|
||||
will listen on 0.0.0.0:29118 (SCTP) for incoming connections.
|
||||
|
||||
This is sufficient in the most configurations, but in larger installations,
|
||||
where services are either tied to specific interfaces and/or more instances of
|
||||
OsmoMSC run in parallel, a custom configuration is necessary.
|
||||
|
||||
The user has the option to configure the IP address (`local-ip`) and the SCTP
|
||||
port (`local-port`) and also the `vlr-name` that OsmoMSC uses to identify itself
|
||||
towards the MME. It should be noted that the `vlr-name` is usually the DNS name
|
||||
for the IP address of the VLR/MSC, so IP address used and the `vlr-name` should
|
||||
match the DNS server entry.
|
||||
|
||||
----
|
||||
sgs
|
||||
local-ip 127.0.0.1
|
||||
local-port 29118
|
||||
vlr-name vlr.example.net
|
||||
----
|
||||
|
||||
In order to fine tune the behavior of the SGs interface the user also has
|
||||
control over the relevant timers (`ts5`, `ts6-2`, `ts7`, `ts11`, `ts14`, `ts15`)
|
||||
and counters (`ns7`, `ns11`). Each timer and counter has to be configured
|
||||
separately. In the following example we change the value of ts and ns11.
|
||||
|
||||
----
|
||||
sgs
|
||||
timer ts7 23
|
||||
counter ns11 100
|
||||
----
|
||||
|
||||
|
||||
[NOTE]
|
||||
====
|
||||
In case multiple instances of OsmoMSC run in parallel, it is advised to use a
|
||||
different `vlr-name` for each instance. In any case it must be ensured that the
|
||||
SGs interface of each instance is bound to a different IP address and/or port.
|
||||
====
|
||||
|
||||
=== Connection monitoring
|
||||
|
||||
The user can use the VTY command `show sgs-connections` to list the MMEs that
|
||||
are currently connected to OsmoMSC.
|
|
@ -38,6 +38,8 @@ include::{srcdir}/chapters/osmux_msc.adoc[]
|
|||
|
||||
include::./common/chapters/mgwpool.adoc[]
|
||||
|
||||
include::{srcdir}/chapters/sgs.adoc[]
|
||||
|
||||
include::./common/chapters/control_if.adoc[]
|
||||
|
||||
include::./common/chapters/gsup.adoc[]
|
||||
|
|
Loading…