This commit fixes 2 functions from util.py:
- setcap_netsys_admin: removed "self" from the arguments.
- create_netns: pass "run_dir" to Process and convert the arguments to
a list as the other methods in the file.
Change-Id: Ida4c6d6500be92b8d1f96e4e7a870e63bd329be9
Adds support to the malloc interceptor for the SRS eNodeB. This interceptor will generate a log file that lists the mallocs, reallocs and frees produced by the srsenb.
Change-Id: I0078020468f58bdd70b0b5de879eb58192f947a6
Sets the remote directory for fapi to the given in the variable 'remote_dir' in the reource schema.
Change-Id: I77a56835a4054b86d1d3f7da823a013b3370f767
Allows to run given scripts before and after the execution of the SRS
eNodeB. The scripts are retrieved as a list from the resource.conf file.
Change-Id: I5017caae933809b89b32ea132be8552d6554e20e
Added the feature to configure the packet length in udp iperf. Added a modifier to select the length value.
The default value is configured to 1460.
Change-Id: Ic886faa82b7cb25f2bce685eb80910623e4ff686
open5gs requires the tun device to be pre-created and pre-configured
before using it. A ticket was opened in order to allow upfd itself
configuring it in [1]
[1] https://github.com/open5gs/open5gs/issues/899
Change-Id: I3b1857f09017cacee1c86f41dae1463c11b50490
use RemoteProcessSafeExit() for launching all open5gs components
to make sure they are stopped at the end as well.
Change-Id: Ia1439577d60f9694da70c4e42c621100c8ef295e
there is no open5gs_enb so having the epc in the name is redundent, also
it safes typing and allows longer scenario configs without exceeding
filename limit.
Change-Id: Ib10bc6031ecc8de88a9c718b136d2641ce46e11d
this patch adds the ability to configure NR cells with
Amarisoft eNB. It adds the new DRB-NR template and updates
the normal enb.cfg template to allow using it as LTE only
or with NR cells (5G NSA).
Change-Id: Ia27bbc6db5920ce14bacabe8043601aa2adaa5fe
this also removes the entire help text around arguments (that
were very outdated already) and only leaves the actual values with changes.
Change-Id: Icb9e8e7b1c68cf024db3a7273af791f017c32003
due to internal PDU buffering between PDCP/RLC the poll frequency
needs to be increase to get quicker feedback.
Change-Id: I4114fb36e675b3f91c471558f716276ab24f1db5
this patch adds generic support for custom frequency bands to the ms class.
it then extends the config template for AmariUE to use them.
we set the default values for EARFCNs for DL/UL to the old values.
Change-Id: I7b2250e13fc1161be1a1d73a4348f07b31c0f724
this config option overwrites the EARFCN config that is typically
used to tell the UE the bands to scan for cells. When custom
frequencies are used, this option allows to set them explicitly.
Change-Id: Ice070ea6755e273d916db2dc941068d33bbe206a
this allows to use the lteue to generate DL traffic. the
server listens on the default spgw address.
Change-Id: Iad081e57e2fd9d3cbc3e59e4f729a4721ad778c9
the UEs count param, if specified, is mapped into the config
values of the EPC so it can be used for template rendering.
Since we only have one count parameter, its added to the first
subscriber. 1 is the default value and its used when no count
param is specified.
this allows to run the Amarisoft UE simulator with the Amarisoft EPC
without having to create subscriber entries for each simulated UE.
Change-Id: I29885791f716c204d0b6f18ba134885bae853b6f
Despite open5gs allowing to change the GTP ports in the config file, in
reality changing those values to something else than the standard prot
will fail. Hence, we must use the standard port. As a result, we must
use different IP addresses in each process to avoid ip+port collisions.
Let's use some loopback addresses which shouldn't require extra
configuration on the host, and still only requiring 1 run_node as per
existing EPCs, with the limitation that only 1 open5gs EPC instance can
be run at one in a given run_node.
Related: https://github.com/open5gs/open5gs/issues/897
Change-Id: Id3062c6ad9d6de4c6066547e1e46edad5da285c1
when they are greater than 0 they are written as config paramter.
if they are -1 they are disbaled and automatic gain calibration is
used.
Change-Id: I473ff3ae679784178574d2f76b612dbf77180490
throughput tests require the UE object to have the num_carriers
member. For Android UEs, set it to 1 by default.
Change-Id: I297d24bb578a7db0eb7629be4f2cc0d54624467d
we've provided only all_log_level so far but sometimes it's needed
to select the level per layer. This patch adds the ability
to do so for the NAS layer in the UE.
Change-Id: Iab2bce65e8af81f6d344849c97952e6441cb2846