manual: Add section describing show gbproxy command usage
Change-Id: Iad2775d125b842f47b0a7b8324fbe417bece04de
This commit is contained in:
parent
226e6cbc8a
commit
78f3a12c8e
|
@ -49,3 +49,47 @@ ns
|
||||||
<1> Define bind with IP/port for the BSS
|
<1> Define bind with IP/port for the BSS
|
||||||
<2> Allow BSS with dynamic NSE to connect to this bind
|
<2> Allow BSS with dynamic NSE to connect to this bind
|
||||||
<3> Use this bind as default for dynamic NSE
|
<3> Use this bind as default for dynamic NSE
|
||||||
|
|
||||||
|
=== Checking OsmoGbProxy state
|
||||||
|
|
||||||
|
The VTY interface (see <<vty>>) offers you commands to inspect the state of
|
||||||
|
OsmoGbProxy.
|
||||||
|
FIXME mention/link to NS VTY chapter
|
||||||
|
|
||||||
|
|
||||||
|
.Example: Check SGSN-side BVCs
|
||||||
|
----
|
||||||
|
OsmoGbProxy# show gbproxy bvc sgsn <1>
|
||||||
|
NSEI 1, SIG-BVCI 0 [UNBLOCKED] <2>
|
||||||
|
NSEI 1, PTP-BVCI 1234, RAI 001-01-1234-0 [UNBLOCKED] <3>
|
||||||
|
NSEI 1, PTP-BVCI 1235, RAI 001-01-1235-0 [BLOCKED] <4>
|
||||||
|
----
|
||||||
|
<1> Show the BVCs towards the SGSN-side
|
||||||
|
<2> A signalling BVC is required before PTP-BVCs can be established
|
||||||
|
<3> For PTP-BVCs show the BVCI and RAI that was sent during the RESET procedure
|
||||||
|
<4> A BVC on the SGSN-side can be blocked either because the BSS blocked the PTP-BVC or if the
|
||||||
|
BSS BVC vanished (due to BVC-RESET or NSE failure). Since there is no way to delete a PTP-BVC
|
||||||
|
it will stay until the SIG-BVC on that NSE is reset.
|
||||||
|
|
||||||
|
.Example: Check BSS-side BVCs
|
||||||
|
----
|
||||||
|
OsmoGbProxy# show gbproxy bvc bss <1>
|
||||||
|
NSEI 1001, SIG-BVCI 0 [UNBLOCKED]
|
||||||
|
NSEI 1001, PTP-BVCI 1234, RAI 001-01-1234-0 [UNBLOCKED] <2>
|
||||||
|
NSEI 1002, SIG-BVCI 0 [UNBLOCKED]
|
||||||
|
NSEI 1002, PTP-BVCI 1235, RAI 001-01-1235-0 [BLOCKED]
|
||||||
|
----
|
||||||
|
<1> Show the BVCs towards the BSS-side
|
||||||
|
<2> The information displayed is the same as for the SGSN-side
|
||||||
|
|
||||||
|
.Example: Show cell information
|
||||||
|
----
|
||||||
|
OsmoGbProxy# show gbproxy cell
|
||||||
|
BVCI 1234 RAI 001-01-1234-0 CID 1234: BSS NSEI 1001, SGSN NSEI 1 <1>
|
||||||
|
BVCI 1235 RAI 001-01-1235-0 CID 1235: BSS NSEI 1002, SGSN NSEI 1
|
||||||
|
BVCI 1236 RAI 001-01-1236-0 CID 1236: BSS NSEI 1003, SGSN NSEI 1 2 <2>
|
||||||
|
BVCI 1237 RAI 001-01-1237-0 CID 1237: BSS NSEI <none>, SGSN NSEI <none> <3>
|
||||||
|
----
|
||||||
|
<1> Show cell information (BVCI, RAI)
|
||||||
|
<2> When multiple SGSNs are connected (SGSN pooling) more than one NSEI is shown
|
||||||
|
<3> If the BSS or SGSN side of a cell is currently disconnected none is shown instead of the NSEI
|