keys to have _uint in their names, to match the routines that handle dissector tables with string keys. (Using _port can confuse people into thinking they're intended solely for use with TCP/UDP/etc. ports when, in fact, they work better for things such as Ethernet types, where the binding of particular values to particular protocols are a lot stronger.) svn path=/trunk/; revision=35224
392 lines
12 KiB
C
392 lines
12 KiB
C
/* packet-ndp.c
|
|
* Routines for the disassembly of the Nortel Discovery Protocol, formerly
|
|
* the SynOptics Network Management Protocol (SONMP).
|
|
* (c) Copyright Giles Scott <giles.scott1 [AT] arubanetworks.com>
|
|
*
|
|
* $Id$
|
|
*
|
|
* Wireshark - Network traffic analyzer
|
|
* By Gerald Combs <gerald@wireshark.org>
|
|
* Copyright 1998 Gerald Combs
|
|
*
|
|
* This program is free software; you can redistribute it and/or
|
|
* modify it under the terms of the GNU General Public License
|
|
* as published by the Free Software Foundation; either version 2
|
|
* of the License, or (at your option) any later version.
|
|
*
|
|
* This program is distributed in the hope that it will be useful,
|
|
* but WITHOUT ANY WARRANTY; without even the implied warranty of
|
|
* MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
|
|
* GNU General Public License for more details.
|
|
*
|
|
* You should have received a copy of the GNU General Public License
|
|
* along with this program; if not, write to the Free Software
|
|
* Foundation, Inc., 59 Temple Place - Suite 330, Boston, MA 02111-1307, USA.
|
|
*
|
|
* This protocol has gone by many names over the years:
|
|
*
|
|
* Bay Discovery Protocol (BDP), Bay Topology Protocol, Bay Network Management
|
|
* Protocol (BNMP), Nortel Management MIB (NMM), Nortel Topology Discovery
|
|
* Protocol (NTDP), SynOptics Network Management Protocol (SONMP).
|
|
* (source: Wikipedia article on "Nortel Discovery Protocol")
|
|
*
|
|
*/
|
|
|
|
#include "config.h"
|
|
|
|
#ifdef HAVE_SYS_TYPES_H
|
|
#include <sys/types.h>
|
|
#endif
|
|
|
|
#include <stdlib.h>
|
|
|
|
#include <glib.h>
|
|
#include <epan/packet.h>
|
|
#include <epan/nlpid.h>
|
|
|
|
/* Although this protocol is proprietary it is documented in the SynOptics MIB's
|
|
* So I'm not giving anything away :-)
|
|
* The only thing I have not done is decode the segment identifier;
|
|
* This changes so much depending on whether the chassis supports
|
|
* multi-segment autotopology. As the 5000 is now EOL don't see much point.
|
|
*
|
|
* MIB's s5emt104.mib, s5tcs112.mib, synro199.mib these should be available via
|
|
* http://www.nortelnetworks.com
|
|
*/
|
|
|
|
|
|
/* chassis types */
|
|
/* Last updated from version 229 ("200609010000Z") of SnpxChassisType in SYNOPTICS-ROOT-MIB.mib */
|
|
static const value_string ndp_chassis_val[] =
|
|
{
|
|
{1, "other"},
|
|
{2, "3000"},
|
|
{3, "3030"},
|
|
{4, "2310"},
|
|
{5, "2810"},
|
|
{6, "2912"},
|
|
{7, "2914"},
|
|
{8, "271x"},
|
|
{9, "2813"},
|
|
{10, "2814"},
|
|
{11, "2915"},
|
|
{12, "5000"},
|
|
{13, "2813SA"},
|
|
{14, "2814SA"},
|
|
{15, "810M"},
|
|
{16, "Ethercell"},
|
|
{17, "5005"},
|
|
{18, "Alcatel Ethernet workgroup conc."},
|
|
|
|
{20, "2715SA"},
|
|
{21, "2486"},
|
|
{22, "28000 series"},
|
|
{23, "23000 series"},
|
|
{24, "5DN00x series"},
|
|
{25, "BayStack Ethernet"},
|
|
{26, "23100 series"},
|
|
{27, "100Base-T Hub"},
|
|
{28, "3000 Fast Ethernet"},
|
|
{29, "Orion switch"},
|
|
/* 30 is "not used" */
|
|
{31, "DDS"},
|
|
{32, "Centillion (6 slot)"},
|
|
{33, "Centillion (12 slot)"},
|
|
{34, "Centillion (1 slot)"},
|
|
{35, "BayStack 301"},
|
|
{36, "BayStack TokenRing Hub"},
|
|
{37, "FVC Multimedia Switch"},
|
|
{38, "Switch Node"},
|
|
{39, "BayStack 302 Switch"},
|
|
{40, "BayStack 350 Switch"},
|
|
{41, "BayStack 150 Ethernet Hub"},
|
|
{42, "Centillion 50N switch"},
|
|
{43, "Centillion 50T switch"},
|
|
{44, "BayStack 303 and 304 Switches"},
|
|
{45, "BayStack 200 Ethernet Hub"},
|
|
{46, "BayStack 250 10/100 Ethernet Hub"},
|
|
/*{47, "StackProbe"}, XXX - No longer listed */
|
|
{48, "BayStack 450 10/100/1000 Switches"},
|
|
{49, "BayStack 410 10/100 Switches"},
|
|
{50, "Passport 1200 L3 Switch"},
|
|
{51, "Passport 1250 L3 Switch"},
|
|
{52, "Passport 1100 L3 Switch"},
|
|
{53, "Passport 1150 L3 Switch"},
|
|
{54, "Passport 1050 L3 Switch"},
|
|
{55, "Passport 1051 L3 Switch"},
|
|
{56, "Passport 8610 L3 Switch"},
|
|
{57, "Passport 8606 L3 Switch"},
|
|
{58, "Passport 8010"},
|
|
{59, "Passport 8006"},
|
|
{60, "BayStack 670 wireless access point"},
|
|
{61, "Passport 740"},
|
|
{62, "Passport 750"},
|
|
{63, "Passport 790"},
|
|
{64, "Business Policy Switch 2000 10/100 Switches"},
|
|
{65, "Passport 8110 L2 Switch"},
|
|
{66, "Passport 8106 L2 Switch"},
|
|
{67, "BayStack 3580 Gig Switch"},
|
|
{68, "BayStack 10 Power Supply Unit"},
|
|
{69, "BayStack 420 10/100 Switch"},
|
|
{70, "OPTera Metro 1200 Ethernet Service Module"},
|
|
{71, "OPTera 8010co"},
|
|
{72, "OPTera 8610co L3 switch"},
|
|
{73, "OPTera 8110co L2 switch"},
|
|
{74, "OPTera 8003"},
|
|
{75, "OPTera 8603 L3 switch"},
|
|
{76, "OPTera 8103 L2 switch"},
|
|
{77, "BayStack 380 10/100/1000 Switch"},
|
|
{78, "Ethernet Switch 470-48T"},
|
|
{79, "OPTera Metro 1450 Ethernet Service Module"},
|
|
{80, "OPTera Metro 1400 Ethernet Service Module"},
|
|
{81, "Alteon Switch Family"},
|
|
{82, "Ethernet Switch 460-24T-PWR"},
|
|
{83, "OPTera Metro 8010 OPM L2 Switch"},
|
|
{84, "OPTera Metro 8010co OPM L2 Switch"},
|
|
{85, "OPTera Metro 8006 OPM L2 Switch"},
|
|
{86, "OPTera Metro 8003 OPM L2 Switch"},
|
|
{87, "Alteon 180e"},
|
|
{88, "Alteon AD3"},
|
|
{89, "Alteon 184"},
|
|
{90, "Alteon AD4"},
|
|
{91, "Passport 1424 L3 switch"},
|
|
{92, "Passport 1648 L3 switch"},
|
|
{93, "Passport 1612 L3 switch"},
|
|
{94, "Passport 1624 L3 switch"},
|
|
{95, "BayStack 380-24F Fiber 1000 Switch"},
|
|
{96, "Ethernet Routing Switch 5510-24T"},
|
|
{97, "Ethernet Routing Switch 5510-48T"},
|
|
{98, "Ethernet Switch 470-24T"},
|
|
{99, "Nortel Networks Wireless LAN Access Point 2220"},
|
|
{100, "Passport RBS 2402 L3 switch"},
|
|
{101, "Alteon Application Switch 2424"},
|
|
{102, "Alteon Application Switch 2224"},
|
|
{103, "Alteon Application Switch 2208"},
|
|
{104, "Alteon Application Switch 2216"},
|
|
{105, "Alteon Application Switch 3408"},
|
|
{106, "Alteon Application Switch 3416"},
|
|
{107, "Nortel Networks Wireless LAN SecuritySwitch 2250"},
|
|
{108, "Ethernet Switch 425-48T"},
|
|
{109, "Ethernet Switch 425-24T"},
|
|
{110, "Nortel Networks Wireless LAN Access Point 2221"},
|
|
{111, "Nortel Metro Ethernet Service Unit 24-T SPF switch"},
|
|
{112, " Nortel Metro Ethernet Service Unit 24-T LX DC switch"},
|
|
{113, "Passport 8300 10-slot chassis"},
|
|
{114, "Passport 8300 6-slot chassis"},
|
|
{115, "Ethernet Routing Switch 5520-24T-PWR"},
|
|
{116, "Ethernet Routing Switch 5520-48T-PWR"},
|
|
{117, "Nortel Networks VPN Gateway 3050"},
|
|
{118, "Alteon SSL 310 10/100"},
|
|
{119, "Alteon SSL 310 10/100 Fiber"},
|
|
{120, "Alteon SSL 310 10/100 FIPS"},
|
|
{121, "Alteon SSL 410 10/100/1000"},
|
|
{122, "Alteon SSL 410 10/100/1000 Fiber"},
|
|
{123, "Alteon Application Switch 2424-SSL"},
|
|
{124, "Ethernet Switch 325-24T"},
|
|
{125, "Ethernet Switch 325-24G"},
|
|
{126, "Nortel Networks Wireless LAN Access Point 2225"},
|
|
{127, "Nortel Networks Wireless LAN SecuritySwitch 2270"},
|
|
{128, "24-port Ethernet Switch 470-24T-PWR"},
|
|
{129, "48-port Ethernet Switch 470-48T-PWR"},
|
|
{130, "Ethernet Routing Switch 5530-24TFD"},
|
|
{131, "Ethernet Switch 3510-24T"},
|
|
{132, "Nortel Metro Ethernet Service Unit 12G AC L3 switch"},
|
|
{133, "Nortel Metro Ethernet Service Unit 12G DC L3 switch"},
|
|
{134, "Nortel Secure Access Switch"},
|
|
{135, "Nortel Networks VPN Gateway 3070"},
|
|
{136, "OPTera Metro 3500"},
|
|
{137, "SMB BES 1010 24T"},
|
|
{138, "SMB BES 1010 48T"},
|
|
{139, "SMB BES 1020 24T PWR"},
|
|
{140, "SMB BES 1020 48T PWR"},
|
|
{141, "SMB BES 2010 24T"},
|
|
{142, "SMB BES 2010 48T"},
|
|
{143, "SMB BES 2020 24T PWR"},
|
|
{144, "SMB BES 2020 48T PWR"},
|
|
{145, "SMB BES 110 24T"},
|
|
{146, "SMB BES 110 48T"},
|
|
{147, "SMB BES 120 24T PWR"},
|
|
{148, "SMB BES 120 48T PWR"},
|
|
{149, "SMB BES 210 24T"},
|
|
{150, "SMB BES 210 48T"},
|
|
{151, "SMB BES 220 24T PWR"},
|
|
{152, "SMB BES 220 48T PWR"},
|
|
{153, "OME 6500"},
|
|
{154, "Ethernet Routing Switch 4548GT"},
|
|
{155, "Ethernet Routing Switch 4548GT-PWR"},
|
|
{156, "Ethernet Routing Switch 4550T"},
|
|
{157, "Ethernet Routing Switch 4550T-PWR"},
|
|
{158, "Ethernet Routing Switch 4526FX"},
|
|
{159, "Ethernet Routing Switch 2500-26T"},
|
|
{160, "Ethernet Routing Switch 2500-26T-PWR"},
|
|
{161, "Ethernet Routing Switch 2500-50T"},
|
|
{162, "Ethernet Routing Switch 2500-50T-PWR"},
|
|
{0, NULL}
|
|
};
|
|
static value_string_ext ndp_chassis_val_ext = VALUE_STRING_EXT_INIT(ndp_chassis_val);
|
|
|
|
/* from synro179.mib - SnpxBackplaneType */
|
|
static const value_string ndp_backplane_val[] =
|
|
{
|
|
{1, "Other"},
|
|
{2, "Ethernet"},
|
|
{3, "Ethernet and Tokenring"},
|
|
{4, "Ethernet and FDDI"},
|
|
{5, "Ethernet, Tokenring and FDDI"},
|
|
{6, "Ethernet and Tokenring with redundant power"},
|
|
{7, "Ethernet, Tokenring, FDDI with redundant power"},
|
|
{8, "Token Ring"},
|
|
{9, "Ethernet, Tokenring and Fast Ethernet"},
|
|
{10, "Ethernet and Fast Ethernet"},
|
|
{11, "Ethernet, Tokenring, Fast Ethernet with redundant power"},
|
|
{12, "Ethernet, Fast Ethernet and Gigabit Ethernet"},
|
|
{0, NULL}
|
|
};
|
|
static value_string_ext ndp_backplane_val_ext = VALUE_STRING_EXT_INIT(ndp_backplane_val);
|
|
|
|
static const value_string ndp_state_val[] =
|
|
{
|
|
{1, "Topology Change"},
|
|
{2, "Heartbeat"},
|
|
{3, "New"},
|
|
{0, NULL}
|
|
};
|
|
|
|
|
|
/* Offsets in NDP Hello structure. */
|
|
#define NDP_IP_ADDRESS 0
|
|
#define NDP_SEGMENT_IDENTIFIER 4
|
|
#define NDP_CHASSIS_TYPE 7
|
|
#define NDP_BACKPLANE_TYPE 8
|
|
#define NDP_STATE 9
|
|
#define NDP_NUMBER_OF_LINKS 10
|
|
|
|
static int proto_ndp = -1;
|
|
static int hf_ndp_ip_address = -1;
|
|
static int hf_ndp_segment_identifier = -1;
|
|
static int hf_ndp_chassis_type = -1;
|
|
static int hf_ndp_backplane_type = -1;
|
|
static int hf_ndp_state = -1;
|
|
static int hf_ndp_number_of_links = -1;
|
|
|
|
static gint ett_ndp = -1;
|
|
|
|
|
|
static void
|
|
dissect_ndp(tvbuff_t *tvb, packet_info *pinfo, proto_tree *tree)
|
|
{
|
|
const char *hello_type;
|
|
proto_tree *ndp_tree = NULL;
|
|
proto_item *ti;
|
|
|
|
col_set_str(pinfo->cinfo, COL_PROTOCOL, "NDP");
|
|
|
|
if (check_col(pinfo->cinfo, COL_INFO)) {
|
|
hello_type = "";
|
|
if (pinfo->dl_dst.type == AT_ETHER) {
|
|
const guint8 *dstmac = pinfo->dl_dst.data;
|
|
|
|
switch (dstmac[5]) {
|
|
|
|
case 0:
|
|
hello_type = "Segment ";
|
|
break;
|
|
|
|
case 1:
|
|
hello_type = "FlatNet ";
|
|
break;
|
|
}
|
|
}
|
|
col_add_fstr(pinfo->cinfo, COL_INFO, "%sHello",
|
|
hello_type);
|
|
}
|
|
|
|
if (tree) {
|
|
ti = proto_tree_add_protocol_format(tree, proto_ndp, tvb, 0, 11,
|
|
"Nortel Discovery Protocol");
|
|
|
|
ndp_tree = proto_item_add_subtree(ti, ett_ndp);
|
|
|
|
proto_tree_add_item(ndp_tree, hf_ndp_ip_address, tvb,
|
|
NDP_IP_ADDRESS, 4, FALSE);
|
|
|
|
|
|
proto_tree_add_item(ndp_tree, hf_ndp_segment_identifier, tvb,
|
|
NDP_SEGMENT_IDENTIFIER, 3, FALSE);
|
|
|
|
|
|
proto_tree_add_item(ndp_tree, hf_ndp_chassis_type, tvb,
|
|
NDP_CHASSIS_TYPE, 1, FALSE);
|
|
|
|
proto_tree_add_item(ndp_tree, hf_ndp_backplane_type, tvb,
|
|
NDP_BACKPLANE_TYPE, 1, FALSE);
|
|
|
|
|
|
proto_tree_add_item(ndp_tree, hf_ndp_state, tvb,
|
|
NDP_STATE, 1, FALSE);
|
|
|
|
proto_tree_add_item(ndp_tree, hf_ndp_number_of_links, tvb,
|
|
NDP_NUMBER_OF_LINKS, 1, FALSE);
|
|
}
|
|
|
|
|
|
}
|
|
|
|
|
|
|
|
void
|
|
proto_register_ndp(void)
|
|
{
|
|
static hf_register_info hf[] = {
|
|
{ &hf_ndp_ip_address,
|
|
{ "IP address", "ndp.ipaddress", FT_IPv4, BASE_NONE, NULL, 0x0,
|
|
"IP address of the Network Management Module (NMM))", HFILL }},
|
|
|
|
{ &hf_ndp_segment_identifier,
|
|
{ "Segment Identifier", "ndp.segmentident", FT_UINT24, BASE_HEX, NULL, 0x0,
|
|
"Segment id of the segment from which the agent is sending the topology message", HFILL }},
|
|
|
|
{ &hf_ndp_chassis_type,
|
|
{ "Chassis type", "ndp.chassis", FT_UINT8, BASE_DEC|BASE_EXT_STRING,
|
|
&ndp_chassis_val_ext, 0x0,
|
|
"Chassis type of the agent sending the topology message", HFILL }},
|
|
|
|
{ &hf_ndp_backplane_type,
|
|
{ "Backplane type", "ndp.backplane", FT_UINT8, BASE_DEC|BASE_EXT_STRING,
|
|
&ndp_backplane_val_ext, 0x0,
|
|
"Backplane type of the agent sending the topology message", HFILL }},
|
|
|
|
{ &hf_ndp_state,
|
|
{ "State", "ndp.state", FT_UINT8, BASE_DEC,
|
|
VALS(ndp_state_val), 0x0,
|
|
"Current state of this Network Management Module (NMM)", HFILL }},
|
|
|
|
{ &hf_ndp_number_of_links,
|
|
{ "Number of links", "ndp.numberoflinks", FT_UINT8, BASE_DEC, NULL, 0x0,
|
|
"Number of interconnect ports", HFILL }},
|
|
};
|
|
|
|
static gint *ett[] = {
|
|
&ett_ndp,
|
|
};
|
|
proto_ndp = proto_register_protocol("Nortel Discovery Protocol", "NDP", "ndp");
|
|
proto_register_field_array(proto_ndp, hf, array_length(hf));
|
|
proto_register_subtree_array(ett, array_length(ett));
|
|
|
|
register_dissector("ndp", dissect_ndp, proto_ndp);
|
|
}
|
|
|
|
void
|
|
proto_reg_handoff_ndp(void)
|
|
{
|
|
dissector_handle_t ndp_handle;
|
|
|
|
ndp_handle = find_dissector("ndp");
|
|
|
|
dissector_add_uint("llc.nortel_pid", 0x01a1, ndp_handle); /* flatnet hello */
|
|
dissector_add_uint("llc.nortel_pid", 0x01a2, ndp_handle); /* Segment hello */
|
|
/* not got round to adding this but its really old, so I'm not sure people will see it */
|
|