1. If there's no character encoding (ENC_ASCII, ...) specified
then use ENC_ASCII.
2. For all but FT_UINT_STRING, always use ENC_NA
(replacing any existing True/1/FALSE/0
/ENC_BIG_ENDIAN/ENC_LITTLE_ENDIAN).
svn path=/trunk/; revision=39426
Specifically: Replace FALSE|0 and TRUE|1 by ENC_BIG_ENDIAN|ENC_LITTLE_ENDIAN as
the encoding parameter for proto_tree_add_item() calls which directly reference
an item in hf[] which has a type of:
FT_UINT8
FT_UINT16
FT_UINT24
FT_UINT32
FT_UINT64
FT_INT8
FT_INT16
FT_INT24
FT_INT32
FT_INT64
FT_FLOAT
FT_DOUBLE
svn path=/trunk/; revision=39288
keys to have _uint in their names, to match the routines that handle
dissector tables with string keys. (Using _port can confuse people into
thinking they're intended solely for use with TCP/UDP/etc. ports when,
in fact, they work better for things such as Ethernet types, where the
binding of particular values to particular protocols are a lot
stronger.)
svn path=/trunk/; revision=35224
(1) Trailing/leading spaces are removed from 'name's/'blurb's
(2) Duplicate 'blurb's are replaced with NULL
(3) Empty ("") 'blurb's are replaced with NULL
(4) BASE_NONE, NULL, 0x0 are used for 'display', 'strings' and 'bitmask' fields
for FT_NONE, FT_BYTES, FT_IPv4, FT_IPv6, FT_ABSOLUTE_TIME, FT_RELATIVE_TIME,
FT_PROTOCOL, FT_STRING and FT_STRINGZ field types
(5) Only allow non-zero value for 'display' if 'bitmask' is non-zero
svn path=/trunk/; revision=28770
Updated dissector for LINX protocols
* Linx Ethernet Connection Manager protocol is updated from version 2 to
version 3.
* Linx RLNH protocol has been updated from version 1 to version 2.
The updated dissector is backwards-compatible allowing correct dissection of
all versions.
svn path=/trunk/; revision=23444
put this stuff into an external file but just doing a forward
declaration to squelch a compiler warning isn't the way to go - it
needs to be done right one day.
svn path=/trunk/; revision=19827
Remove preferences stuff
Use stringz for variable length names
Media address size independant
Removed generated item
Set actual length of packet
Make info column work without coloring rules or filters
svn path=/trunk/; revision=19435
dissector for Enea's LINX protocol?
A protocol spec is available at <http://www.enea.com/templates/Extension____8947.aspx>. The source of the kernel module could be obtained from Enea by sending a request to "linx at enea dot com".
Currently they use ethertype 0x9999 which is not registered at IEEE.
svn path=/trunk/; revision=19430