According to Table 161 in ETSI 392-2 standard, the Class of MS field in
U-LOCATION UPDATE DEMAND in tetra.asn is incorrect. the type of Class of MS
field should be Type 2, not Type 1, and the length should be 24 bits, not
32bits.
https://bugs.wireshark.org/bugzilla/show_bug.cgi?id=7946
svn path=/trunk/; revision=45857
- Code Cleanups and preparation to call code from gsmtap
- Fix a bug in the asn1 file, Bug found with traces from OsmocomTETRA
svn path=/trunk/; revision=35754
they made the decision to use the ASN1 infrastructure for creating the dissector and were kind enough to send the
GPLed sourcecode to us(The Osmocom Group). This group is using a protocol provided by their equipment.
This is an initial checkin of the code from BIT, it is not fit for inclusion in Wireshark in this state. Further patches are expected
before the code can be integrated by being added to the makefiles.
svn path=/trunk/; revision=35753