wireshark/epan/dissectors/packet-zbee-aps.h

324 lines
15 KiB
C
Raw Normal View History

/* packet-zbee-aps.h
* Dissector routines for the ZigBee Application Support Sub-layer (APS)
* By Owen Kirby <osk@exegin.com>
* Copyright 2009 Exegin Technologies Limited
*
* Wireshark - Network traffic analyzer
* By Gerald Combs <gerald@wireshark.org>
* Copyright 1998 Gerald Combs
*
* SPDX-License-Identifier: GPL-2.0-or-later
*/
#ifndef PACKET_ZBEE_APS_H
#define PACKET_ZBEE_APS_H
/* ZigBee APS */
#define ZBEE_APS_FCF_FRAME_TYPE 0x03
#define ZBEE_APS_FCF_DELIVERY_MODE 0x0c
#define ZBEE_APS_FCF_INDIRECT_MODE 0x10 /* ZigBee 2004 and earlier. */
#define ZBEE_APS_FCF_ACK_FORMAT 0x10 /* ZigBee 2007 and later. */
#define ZBEE_APS_FCF_SECURITY 0x20
#define ZBEE_APS_FCF_ACK_REQ 0x40
#define ZBEE_APS_FCF_EXT_HEADER 0x80
#define ZBEE_APS_FCF_DATA 0x00
#define ZBEE_APS_FCF_CMD 0x01
#define ZBEE_APS_FCF_ACK 0x02
#define ZBEE_APS_FCF_INTERPAN 0x03
#define ZBEE_APS_FCF_UNICAST 0x00
#define ZBEE_APS_FCF_INDIRECT 0x01
#define ZBEE_APS_FCF_BCAST 0x02
#define ZBEE_APS_FCF_GROUP 0x03 /* ZigBee 2006 and later. */
#define ZBEE_APS_EXT_FCF_FRAGMENT 0x03
#define ZBEE_APS_EXT_FCF_FRAGMENT_NONE 0x00
#define ZBEE_APS_EXT_FCF_FRAGMENT_FIRST 0x01
#define ZBEE_APS_EXT_FCF_FRAGMENT_MIDDLE 0x02
#define ZBEE_APS_CMD_SKKE1 0x01
#define ZBEE_APS_CMD_SKKE2 0x02
#define ZBEE_APS_CMD_SKKE3 0x03
#define ZBEE_APS_CMD_SKKE4 0x04
#define ZBEE_APS_CMD_TRANSPORT_KEY 0x05
#define ZBEE_APS_CMD_UPDATE_DEVICE 0x06
#define ZBEE_APS_CMD_REMOVE_DEVICE 0x07
#define ZBEE_APS_CMD_REQUEST_KEY 0x08
#define ZBEE_APS_CMD_SWITCH_KEY 0x09
#define ZBEE_APS_CMD_EA_INIT_CHLNG 0x0a
#define ZBEE_APS_CMD_EA_RESP_CHLNG 0x0b
#define ZBEE_APS_CMD_EA_INIT_MAC_DATA 0x0c
#define ZBEE_APS_CMD_EA_RESP_MAC_DATA 0x0d
#define ZBEE_APS_CMD_TUNNEL 0x0e
#define ZBEE_APS_CMD_VERIFY_KEY 0x0f
#define ZBEE_APS_CMD_CONFIRM_KEY 0x10
#define ZBEE_APS_CMD_KEY_TC_MASTER 0x00
#define ZBEE_APS_CMD_KEY_STANDARD_NWK 0x01
#define ZBEE_APS_CMD_KEY_APP_MASTER 0x02
#define ZBEE_APS_CMD_KEY_APP_LINK 0x03
#define ZBEE_APS_CMD_KEY_TC_LINK 0x04
#define ZBEE_APS_CMD_KEY_HIGH_SEC_NWK 0x05
#define ZBEE_APS_CMD_SKKE_DATA_LENGTH 16
#define ZBEE_APS_CMD_KEY_LENGTH 16
#define ZBEE_APS_CMD_REQ_NWK_KEY 0x01
#define ZBEE_APS_CMD_REQ_APP_KEY 0x02
#define ZBEE_APS_CMD_UPDATE_STANDARD_SEC_REJOIN 0x00
#define ZBEE_APS_CMD_UPDATE_STANDARD_UNSEC_JOIN 0x01
#define ZBEE_APS_CMD_UPDATE_LEAVE 0x02
#define ZBEE_APS_CMD_UPDATE_STANDARD_UNSEC_REJOIN 0x03
#define ZBEE_APS_CMD_UPDATE_HIGH_SEC_REJOIN 0x04
#define ZBEE_APS_CMD_UPDATE_HIGH_UNSEC_JOIN 0x05
#define ZBEE_APS_CMD_UPDATE_HIGH_UNSEC_REJOIN 0x07
#define ZBEE_APS_CMD_EA_KEY_NWK 0x00
#define ZBEE_APS_CMD_EA_KEY_LINK 0x01
#define ZBEE_APS_CMD_EA_CHALLENGE_LENGTH 16
#define ZBEE_APS_CMD_EA_MAC_LENGTH 16
#define ZBEE_APS_CMD_EA_DATA_LENGTH 4
/* Fields for ZigBee 2004 and earlier. */
#define ZBEE_APP_TYPE 0xF0
#define ZBEE_APP_COUNT 0x0F
#define ZBEE_APP_TYPE_KVP 0x01
#define ZBEE_APP_TYPE_MSG 0x02
#define ZBEE_APP_KVP_CMD 0x0F
#define ZBEE_APP_KVP_TYPE 0xF0
#define ZBEE_APP_KVP_SET 0x01
#define ZBEE_APP_KVP_EVENT 0x02
#define ZBEE_APP_KVP_GET_ACK 0x04
#define ZBEE_APP_KVP_SET_ACK 0x05
#define ZBEE_APP_KVP_EVENT_ACK 0x06
#define ZBEE_APP_KVP_GET_RESP 0x08
#define ZBEE_APP_KVP_SET_RESP 0x09
#define ZBEE_APP_KVP_EVENT_RESP 0x0A
#define ZBEE_APP_KVP_NO_DATA 0x00
#define ZBEE_APP_KVP_UINT8 0x01
#define ZBEE_APP_KVP_INT8 0x02
#define ZBEE_APP_KVP_UINT16 0x03
#define ZBEE_APP_KVP_INT16 0x04
#define ZBEE_APP_KVP_FLOAT16 0x0B
#define ZBEE_APP_KVP_ABS_TIME 0x0C
#define ZBEE_APP_KVP_REL_TIME 0x0D
#define ZBEE_APP_KVP_CHAR_STRING 0x0E
#define ZBEE_APP_KVP_OCT_STRING 0x0F
#define ZBEE_APP_KVP_OVERHEAD 4
/* ZCL Cluster IDs - General */
#define ZBEE_ZCL_CID_BASIC 0x0000
#define ZBEE_ZCL_CID_POWER_CONFIG 0x0001
#define ZBEE_ZCL_CID_DEVICE_TEMP_CONFIG 0x0002
#define ZBEE_ZCL_CID_IDENTIFY 0x0003
#define ZBEE_ZCL_CID_GROUPS 0x0004
#define ZBEE_ZCL_CID_SCENES 0x0005
#define ZBEE_ZCL_CID_ON_OFF 0x0006
#define ZBEE_ZCL_CID_ON_OFF_SWITCH_CONFIG 0x0007
#define ZBEE_ZCL_CID_LEVEL_CONTROL 0x0008
#define ZBEE_ZCL_CID_ALARMS 0x0009
#define ZBEE_ZCL_CID_TIME 0x000a
#define ZBEE_ZCL_CID_RSSI_LOCATION 0x000b
#define ZBEE_ZCL_CID_ANALOG_INPUT_BASIC 0x000c
#define ZBEE_ZCL_CID_ANALOG_OUTPUT_BASIC 0x000d
#define ZBEE_ZCL_CID_ANALOG_VALUE_BASIC 0x000e
#define ZBEE_ZCL_CID_BINARY_INPUT_BASIC 0x000f
#define ZBEE_ZCL_CID_BINARY_OUTPUT_BASIC 0x0010
#define ZBEE_ZCL_CID_BINARY_VALUE_BASIC 0x0011
#define ZBEE_ZCL_CID_MULTISTATE_INPUT_BASIC 0x0012
#define ZBEE_ZCL_CID_MULTISTATE_OUTPUT_BASIC 0x0013
#define ZBEE_ZCL_CID_MULTISTATE_VALUE_BASIC 0x0014
#define ZBEE_ZCL_CID_COMMISSIONING 0x0015
#define ZBEE_ZCL_CID_PARTITION 0x0016
#define ZBEE_ZCL_CID_OTA_UPGRADE 0x0019
#define ZBEE_ZCL_CID_POLL_CONTROL 0x0020
#define ZBEE_ZCL_CID_GP 0x0021
/* */
#define ZBEE_ZCL_CID_POWER_PROFILE 0x001a
#define ZBEE_ZCL_CID_APPLIANCE_CONTROL 0x001b
/* ZCL Cluster IDs - Closures */
#define ZBEE_ZCL_CID_SHADE_CONFIG 0x0100
#define ZBEE_ZCL_CID_DOOR_LOCK 0X0101
/* ZCL Cluster IDs - HVAC */
#define ZBEE_ZCL_CID_PUMP_CONFIG_CONTROL 0x0200
#define ZBEE_ZCL_CID_THERMOSTAT 0x0201
#define ZBEE_ZCL_CID_FAN_CONTROL 0x0202
#define ZBEE_ZCL_CID_DEHUMIDIFICATION_CONTROL 0x0203
#define ZBEE_ZCL_CID_THERMOSTAT_UI_CONFIG 0x0204
/* ZCL Cluster IDs - Lighting */
#define ZBEE_ZCL_CID_COLOR_CONTROL 0x0300
#define ZBEE_ZCL_CID_BALLAST_CONFIG 0x0301
/* ZCL Cluster IDs - Measurement and Sensing */
#define ZBEE_ZCL_CID_ILLUMINANCE_MEASUREMENT 0x0400
#define ZBEE_ZCL_CID_ILLUMINANCE_LEVEL_SENSING 0x0401
#define ZBEE_ZCL_CID_TEMPERATURE_MEASUREMENT 0x0402
#define ZBEE_ZCL_CID_PRESSURE_MEASUREMENT 0x0403
#define ZBEE_ZCL_CID_FLOW_MEASUREMENT 0x0404
#define ZBEE_ZCL_CID_REL_HUMIDITY_MEASUREMENT 0x0405
#define ZBEE_ZCL_CID_OCCUPANCY_SENSING 0x0406
/* ZCL Cluster IDs - Security and Safety */
#define ZBEE_ZCL_CID_IAS_ZONE 0x0500
#define ZBEE_ZCL_CID_IAS_ACE 0x0501
#define ZBEE_ZCL_CID_IAS_WD 0x0502
/* ZCL Cluster IDs - Protocol Interfaces */
#define ZBEE_ZCL_CID_GENERIC_TUNNEL 0x0600
#define ZBEE_ZCL_CID_BACNET_PROTOCOL_TUNNEL 0x0601
#define ZBEE_ZCL_CID_BACNET_ANALOG_INPUT_REG 0x0602
#define ZBEE_ZCL_CID_BACNET_ANALOG_INPUT_EXT 0x0603
#define ZBEE_ZCL_CID_BACNET_ANALOG_OUTPUT_REG 0x0604
#define ZBEE_ZCL_CID_BACNET_ANALOG_OUTPUT_EXT 0x0605
#define ZBEE_ZCL_CID_BACNET_ANALOG_VALUE_REG 0x0606
#define ZBEE_ZCL_CID_BACNET_ANALOG_VALUE_EXT 0x0607
#define ZBEE_ZCL_CID_BACNET_BINARY_INPUT_REG 0x0608
#define ZBEE_ZCL_CID_BACNET_BINARY_INPUT_EXT 0x0609
#define ZBEE_ZCL_CID_BACNET_BINARY_OUTPUT_REG 0x060a
#define ZBEE_ZCL_CID_BACNET_BINARY_OUTPUT_EXT 0x060b
#define ZBEE_ZCL_CID_BACNET_BINARY_VALUE_REG 0x060c
#define ZBEE_ZCL_CID_BACNET_BINARY_VALUE_EXT 0x060d
#define ZBEE_ZCL_CID_BACNET_MULTISTATE_INPUT_REG 0x060e
#define ZBEE_ZCL_CID_BACNET_MULTISTATE_INPUT_EXT 0x060f
#define ZBEE_ZCL_CID_BACNET_MULTISTATE_OUTPUT_REG 0x0610
#define ZBEE_ZCL_CID_BACNET_MULTISTATE_OUTPUT_EXT 0x0611
#define ZBEE_ZCL_CID_BACNET_MULTISTATE_VALUE_REG 0x0612
#define ZBEE_ZCL_CID_BACNET_MULTISTATE_VALUE_EXT 0x0613
/* ZCL Cluster IDs - Smart Energy */
#define ZBEE_ZCL_CID_KEEP_ALIVE 0x0025
#define ZBEE_ZCL_CID_PRICE 0x0700
#define ZBEE_ZCL_CID_DEMAND_RESPONSE_LOAD_CONTROL 0x0701
#define ZBEE_ZCL_CID_SIMPLE_METERING 0x0702
#define ZBEE_ZCL_CID_MESSAGE 0x0703
Fixed bug in ZigBee (zbee) decryption, added Key Establishment cluster and moved IAS, Thermostat and Poll clusters out of the ZCL foundation dissector. Removed attrID and cmdID ZCL cluster functions. Bug in ZCL HVAC attribute registration. Fixed bug in ZCL command ID field registration. Update Manufacturer Codes and Profile Ids to ZigBee-053874r26 Oct 2014 Fixed broken fragmented ZigBee packet collection and reassembly Use protocol fields for Thermostat schedule transitions. Added support for Key Establishment Cluster (CBKE) at SE 1.2a Updated Message cluster to SE 1.2a spec Added attribute reporting status which is common to all SE 1.2a clusters Added SE 1.2a tunnel cluster support ZigBee Smart Energy (SE) decryption appears to have been broken for some time. For SE you do not know the Link Key until after successful completion of Key Establishment and then manually enter it into preferences. Entry in preferences was broken such that when the new Link Key was entered all existing link keys would be lost. This lead to the loss of the Network Key as well when the Transport Key message was re-processed without the Pre-Configured Link Key. The Link Key 'key ring' has been moved to the UAT post-update callback so that it will always be updated correctly after changes to the link keys in preferences The attribute reporting status attribute which is common to all SE clusters was accidentally shared, now each cluster has it's own instance ZigBee security added key display for decrypted packets ZigBee Security Preferences fixed UAT type for Label so key label is editable again Added definition for Retail Service profile Added dissection for profile-wide (General Command Frame) commands when the profile is unknown Added zbee-zcl-misc.c to precommit check whitelist as it contains ias and hvac clusters avoiding proliferation of too many small files Change-Id: I53d85ba9d782db6a0e7e78c51b0bc7cdcdbca3ad Reviewed-on: https://code.wireshark.org/review/5565 Petri-Dish: Alexis La Goutte <alexis.lagoutte@gmail.com> Tested-by: Petri Dish Buildbot <buildbot-no-reply@wireshark.org> Reviewed-by: Anders Broman <a.broman58@gmail.com>
2014-11-07 22:11:02 +00:00
#define ZBEE_ZCL_CID_TUNNELING 0x0704
#define ZBEE_ZCL_CID_PRE_PAYMENT 0x0705
Fixed bug in ZigBee (zbee) decryption, added Key Establishment cluster and moved IAS, Thermostat and Poll clusters out of the ZCL foundation dissector. Removed attrID and cmdID ZCL cluster functions. Bug in ZCL HVAC attribute registration. Fixed bug in ZCL command ID field registration. Update Manufacturer Codes and Profile Ids to ZigBee-053874r26 Oct 2014 Fixed broken fragmented ZigBee packet collection and reassembly Use protocol fields for Thermostat schedule transitions. Added support for Key Establishment Cluster (CBKE) at SE 1.2a Updated Message cluster to SE 1.2a spec Added attribute reporting status which is common to all SE 1.2a clusters Added SE 1.2a tunnel cluster support ZigBee Smart Energy (SE) decryption appears to have been broken for some time. For SE you do not know the Link Key until after successful completion of Key Establishment and then manually enter it into preferences. Entry in preferences was broken such that when the new Link Key was entered all existing link keys would be lost. This lead to the loss of the Network Key as well when the Transport Key message was re-processed without the Pre-Configured Link Key. The Link Key 'key ring' has been moved to the UAT post-update callback so that it will always be updated correctly after changes to the link keys in preferences The attribute reporting status attribute which is common to all SE clusters was accidentally shared, now each cluster has it's own instance ZigBee security added key display for decrypted packets ZigBee Security Preferences fixed UAT type for Label so key label is editable again Added definition for Retail Service profile Added dissection for profile-wide (General Command Frame) commands when the profile is unknown Added zbee-zcl-misc.c to precommit check whitelist as it contains ias and hvac clusters avoiding proliferation of too many small files Change-Id: I53d85ba9d782db6a0e7e78c51b0bc7cdcdbca3ad Reviewed-on: https://code.wireshark.org/review/5565 Petri-Dish: Alexis La Goutte <alexis.lagoutte@gmail.com> Tested-by: Petri Dish Buildbot <buildbot-no-reply@wireshark.org> Reviewed-by: Anders Broman <a.broman58@gmail.com>
2014-11-07 22:11:02 +00:00
#define ZBEE_ZCL_CID_ENERGY_MANAGEMENT 0x0706
#define ZBEE_ZCL_CID_CALENDAR 0x0707
#define ZBEE_ZCL_CID_DEVICE_MANAGEMENT 0x0708
#define ZBEE_ZCL_CID_EVENTS 0x0709
#define ZBEE_ZCL_CID_MDU_PAIRING 0x070A
#define ZBEE_ZCL_CID_SUB_GHZ 0x070B
Fixed bug in ZigBee (zbee) decryption, added Key Establishment cluster and moved IAS, Thermostat and Poll clusters out of the ZCL foundation dissector. Removed attrID and cmdID ZCL cluster functions. Bug in ZCL HVAC attribute registration. Fixed bug in ZCL command ID field registration. Update Manufacturer Codes and Profile Ids to ZigBee-053874r26 Oct 2014 Fixed broken fragmented ZigBee packet collection and reassembly Use protocol fields for Thermostat schedule transitions. Added support for Key Establishment Cluster (CBKE) at SE 1.2a Updated Message cluster to SE 1.2a spec Added attribute reporting status which is common to all SE 1.2a clusters Added SE 1.2a tunnel cluster support ZigBee Smart Energy (SE) decryption appears to have been broken for some time. For SE you do not know the Link Key until after successful completion of Key Establishment and then manually enter it into preferences. Entry in preferences was broken such that when the new Link Key was entered all existing link keys would be lost. This lead to the loss of the Network Key as well when the Transport Key message was re-processed without the Pre-Configured Link Key. The Link Key 'key ring' has been moved to the UAT post-update callback so that it will always be updated correctly after changes to the link keys in preferences The attribute reporting status attribute which is common to all SE clusters was accidentally shared, now each cluster has it's own instance ZigBee security added key display for decrypted packets ZigBee Security Preferences fixed UAT type for Label so key label is editable again Added definition for Retail Service profile Added dissection for profile-wide (General Command Frame) commands when the profile is unknown Added zbee-zcl-misc.c to precommit check whitelist as it contains ias and hvac clusters avoiding proliferation of too many small files Change-Id: I53d85ba9d782db6a0e7e78c51b0bc7cdcdbca3ad Reviewed-on: https://code.wireshark.org/review/5565 Petri-Dish: Alexis La Goutte <alexis.lagoutte@gmail.com> Tested-by: Petri Dish Buildbot <buildbot-no-reply@wireshark.org> Reviewed-by: Anders Broman <a.broman58@gmail.com>
2014-11-07 22:11:02 +00:00
/* ZCL Cluster IDs - Key Establishment */
#define ZBEE_ZCL_CID_KE 0x0800
/* ZCL Cluster IDs - Home Automation */
#define ZBEE_ZCL_CID_APPLIANCE_IDENTIFICATION 0x0b00
#define ZBEE_ZCL_CID_METER_IDENTIFICATION 0x0b01
#define ZBEE_ZCL_CID_APPLIANCE_EVENTS_AND_ALERT 0x0b02
#define ZBEE_ZCL_CID_APPLIANCE_STATISTICS 0x0b03
#define ZBEE_ZCL_CID_ZLL 0x1000
/* ZCL Test Profile #2 Clusters */
#define ZBEE_APS_T2_CID_TCP 0x0001
#define ZBEE_APS_T2_CID_RESPC 0x0002
#define ZBEE_APS_T2_CID_RETPC 0x0003
#define ZBEE_APS_T2_CID_PCR 0x0004
#define ZBEE_APS_T2_CID_BTREQ 0x001c
#define ZBEE_APS_T2_CID_BTGREQ 0x001d
#define ZBEE_APS_T2_CID_BTRES 0x0054
#define ZBEE_APS_T2_CID_BTRES_S_SBT 0x00
#define ZBEE_APS_T2_CID_BTRES_S_TFOFA 0x01
#define ZBEE_APS_T2_CID_BTGRES 0x0055
#define ZBEE_APS_T2_CID_RDREQ 0x1000
#define ZBEE_APS_T2_CID_RDRES 0x1001
#define ZBEE_APS_T2_CID_FREQ 0xa0a8
#define ZBEE_APS_T2_CID_FRES 0xe000
#define ZBEE_APS_T2_CID_FNDR 0xe001
#define ZBEE_APS_T2_CID_BR 0xf000
#define ZBEE_APS_T2_CID_BTADR 0xf001
#define ZBEE_APS_T2_CID_BTARXOWIDR 0xf00a
#define ZBEE_APS_T2_CID_BTARACR 0xf00e
#define ZBEE_APP_STATUS_SUCCESS 0x00 /*A request has been executed successfully.*/
#define ZBEE_APP_STATUS_ASDU_TOO_LONG 0xa0 /*A transmit request failed since the ASDU is too large and fragmentation is not supported.*/
#define ZBEE_APP_STATUS_DEFRAG_DEFERRED 0xa1 /*A received fragmented frame could not be defragmented at the current time.*/
#define ZBEE_APP_STATUS_DEFRAG_UNSUPPORTED 0xa2 /*A received fragmented frame could not be defragmented since the device does not support fragmentation.*/
#define ZBEE_APP_STATUS_ILLEGAL_REQUEST 0xa3 /*A parameter value was out of range.*/
#define ZBEE_APP_STATUS_INVALID_BINDING 0xa4 /*An APSME-UNBIND.request failed due to the requested binding link not existing in the binding table.*/
#define ZBEE_APP_STATUS_INVALID_GROUP 0xa5 /*An APSME-REMOVE-GROUP.request has been issued with a group identifier that does not appear in the group table.*/
#define ZBEE_APP_STATUS_INVALID_PARAMETER 0xa6 /*A parameter value was invalid or out of range.*/
#define ZBEE_APP_STATUS_NO_ACK 0xa7 /*An APSDE-DATA.request requesting acknowledged trans-mission failed due to no acknowledgement being received.*/
#define ZBEE_APP_STATUS_NO_BOUND_DEVICE 0xa8 /*An APSDE-DATA.request with a destination addressing mode set to 0x00 failed due to there being no devices bound to this device.*/
#define ZBEE_APP_STATUS_NO_SHORT_ADDRESS 0xa9 /*An APSDE-DATA.request with a destination addressing mode set to 0x03 failed due to no corresponding short address found*/
#define ZBEE_APP_STATUS_NOT_SUPPORTED 0xaa /*An APSDE-DATA.request with a destination addressing mode set to 0x00 failed due to a binding table not being supported on the device.*/
#define ZBEE_APP_STATUS_SECURED_LINK_KEY 0xab /*An ASDU was received that was secured using a link key.*/
#define ZBEE_APP_STATUS_SECURED_NWK_KEY 0xac /*An ASDU was received that was secured using a network key.*/
#define ZBEE_APP_STATUS_SECURITY_FAIL 0xad /*An APSDE-DATA.request requesting security has resulted in an error during the corresponding security processing.*/
#define ZBEE_APP_STATUS_TABLE_FULL 0xae /*An APSME-BIND.request or APSME.ADD-GROUP.request issued when the binding or group tables, respectively, were full.*/
#define ZBEE_APP_STATUS_UNSECURED 0xaf /*An ASDU was received without any security.*/
#define ZBEE_APP_STATUS_UNSUPPORTED_ATTRIBUTE 0xb0 /*An APSME-GET.request or APSME-SET.request has been issued with an unknown attribute identifier.*/
/* Structure to contain the APS frame information */
typedef struct{
gboolean indirect_mode; /* ZigBee 2004 and Earlier */
guint8 type;
guint8 delivery;
gboolean ack_format; /* ZigBee 2007 and Later */
gboolean security;
gboolean ack_req;
gboolean ext_header; /* ZigBee 2007 and Later */
guint8 dst;
guint16 group; /* ZigBee 2006 and Later */
guint16 profile;
guint8 src;
guint8 counter;
/* Fragmentation Fields. */
guint8 fragmentation; /* ZigBee 2007 and Later */
guint8 block_number; /* ZigBee 2007 and Later */
/* Some helpers for the upper layers. */
gboolean profile_present;
gboolean dst_present;
gboolean src_present;
} zbee_aps_packet;
/* ZigBee Smart Energy version used for preferences */
extern gint gPREF_zbee_se_protocol_version;
enum {
ZBEE_SE_VERSION_1_1B,
ZBEE_SE_VERSION_1_2,
ZBEE_SE_VERSION_1_2A,
ZBEE_SE_VERSION_1_2B,
ZBEE_SE_VERSION_1_4
};
/**************************************
* Value Strings
**************************************
*/
extern const value_string zbee_aps_cid_names[];
extern const range_string zbee_aps_apid_names[];
#endif /* PACKET_ZBEE_APS_H*/
/*
* Editor modelines - http://www.wireshark.org/tools/modelines.html
*
* Local variables:
* c-basic-offset: 4
* tab-width: 8
* indent-tabs-mode: nil
* End:
*
* vi: set shiftwidth=4 tabstop=8 expandtab:
* :indentSize=4:tabSize=8:noTabs=true:
*/