[[counters]]
== Counters
include::./counters_generated.adoc[]
=== Rate Counter Configurable Error Thresholds
Some rate counters such as overruns, underruns and dropped packets indicate
events that can really harm correct operation of the BTS served by OsmoTRX,
specially if they happen frequently. OsmoTRX is in most cases (depending on
maturity of device driver) prepared to dodge the temporary failure and keep
running and providing service.
Still, it is sometimes important for this kind of events to not go unnoticed by
the operator, since they may indicate issues regarding the set up that may
require operator intervention to fix it.
For instance, frequent dropped packets could indicate SDR HW/FW/power errors, or
a faulty connection against the host running OsmoTRX.
They can also indicate issues on the host running OsmoTRX itself: For instance,
OsmoTRX may not be running under a high enough priority (hence other processes
eventually battling for resources with it), or that simply the HW running
OsmoTRX is not powerful enough to accomplish all work in a timely fashion all
the time.
As a result, OsmoTRX can be configured to exit the process upon certain
conditions being met, in order to let osmoBTS notice something is wrong and thus
announcing issues through alarms to the network, where the operator can then
investigate the issue by looking at OsmoTRX logs.
These conditions are configured by means of introducing rate counter thresholds
in the VTY. The OsmoTRX user can provide those threshold commands either in the
VTY cfg file read by OsmoTRX process during startup, or by adding/removing them
dynamically through the VTY interactive console.
Each threshold cmd states an event (a rate counter type), a value and an time
interval (a second, a minute, an hour or a day). A threshold will be reached
(and OsmoTRX stopped) if its value grows bigger than the configured threshold
value over the configured time interval. This is the syntax used to manage rate
counter thresholds:
`(no) ctr-error-threshold <EVENT> <VALUE> <INTERVAL>`
If several rate counter thresholds are set, then all of them are checked over
time and the first one reached will stop OsmoTRX.
.Example: rate counter threshold configuration (VTY .cfg file)
----
trx
ctr-error-threshold rx_drop_events 2 per-minute <1>
ctr-error-threshold rx_drop_samples 800 per-second <2>
----
<1> Stop OsmoTRX if dropped event (any amount of samples) during Rx was detected 2 times or more during a minute.
<2> Stop OsmoTRX if 800 or more samples were detected during Rx to be dropped by the HW during a second.
.Example: rate counter threshold configuration (VTY interactive)
----
OsmoTRX(config-trx)# ctr-error-threshold tx_underruns 3 per-hour <1>
OsmoTRX(config-trx)# no ctr-error-threshold tx_underruns 3 per-hour <2>
----
<1> Stop OsmoTRX if 3 or more underruns were detected during Tx over the last hour
<2> Remove previously set rate counter threshold