== Configuring OsmoSIPConnector
|
|
|
|
The configuration of OsmoSIPConnector consists mainly of two parts:
|
|
configuring the MNCC interface towards the MSC and configuring the SIP
|
|
interface towards the PBX.
|
|
|
|
=== Configuring MNCC
|
|
|
|
Configuring the MNCC interface is very simple. It has to be pointed to
|
|
the same path that OsmoMSC is also using. This means that OsmoMSC and
|
|
OsmoSIPConnector need to be running on the same machine or have a shared
|
|
directory that supports UNIX domain sockets.
|
|
|
|
Note that you need to start `osmo-msc` with the `--mncc-sock` option and point
|
|
to the same file that osmo-sip-connector is configured to use. See the OsmoMSC
|
|
manual for more information.
|
|
|
|
The example config below assumes that OsmoMSC was started with the command
|
|
line `osmo-msc -M /tmp/msc_mncc`.
|
|
|
|
.Example: MNCC configuration
|
|
----
|
|
OsmoSIPcon(config)# mncc
|
|
OsmoSIPcon(config-mncc)# socket-path /tmp/msc_mncc
|
|
----
|
|
|
|
=== Configuring SIP
|
|
|
|
This section covers the SIP configuration. Source and destination IP and port
|
|
can be set for the connection to the PBX.
|
|
|
|
.Example: SIP configuration
|
|
----
|
|
OsmoSIPcon(config)# sip
|
|
OsmoSIPcon(config-sip)# local 10.0.0.1 5060 <1>
|
|
OsmoSIPcon(config-sip)# remote 10.0.0.2 5060 <2>
|
|
----
|
|
<1> The local IP/port to use
|
|
<2> The remote SIP IP/port that the PBX uses
|
|
|
|
There is also an option to use the IMSI as calling (source) address for
|
|
MO- and as called (destination) address for MT-calls.
|
|
|
|
.Example: Use IMSI instead of MSISDN
|
|
----
|
|
OsmoSIPcon(config)# app
|
|
OsmoSIPcon(config-app)# use-imsi <1>
|
|
----
|
|
<1> Use the IMSI for MO calling and MT called address
|
|
|
|
Since OsmoSIPConnector is just a shim between OsmoMSC and a proper SIP server
|
|
this is the extent of the configuration. Setting up a dialplan and other
|
|
SIP-related configuration should be done in the actual SIP server.
|