MNCC<->SIP bridge; attaches to OsmoMSC to interface with external SIP VoIP telephony https://osmocom.org/projects/osmo-sip-conector
Go to file
Holger Hans Peter Freyther 4f8cafa5b0 call: Continue up to the point of call routing
We accept the call on MNCC and ask the core to select/create the
second leg of the call.
2016-03-23 17:41:23 +01:00
doc/examples vty: Work on configuration of the MNCC to SIP gateway 2016-03-21 15:39:41 +01:00
src call: Continue up to the point of call routing 2016-03-23 17:41:23 +01:00
.gitignore Initial commit for a MNCC to SIP gateway (and maybe auth GW too) 2016-03-21 09:54:37 +01:00
COPYING Initial commit for a MNCC to SIP gateway (and maybe auth GW too) 2016-03-21 09:54:37 +01:00
Makefile.am Initial commit for a MNCC to SIP gateway (and maybe auth GW too) 2016-03-21 09:54:37 +01:00
README.asciidoc doc: Update with some requirements and limitations 2016-03-23 17:02:32 +01:00
configure.ac Initial commit for a MNCC to SIP gateway (and maybe auth GW too) 2016-03-21 09:54:37 +01:00
git-version-gen Initial commit for a MNCC to SIP gateway (and maybe auth GW too) 2016-03-21 09:54:37 +01:00

README.asciidoc

Osmo SIP Connector
==================

Simple utility to map MNCC to SIP and SIP to MNCC. The VTY interface
can be used to make configurations. The code doesn't have any RTP or
transcoding support.

Call identities can be either the MSISDN or the IMSI of the subscriber.


Requirements of Equipment
^^^^^^^^^^^^^^^^^^^^^^^^^

* DTMF need to be sent using SIP INFO messages. DTMF in RTP is not
supported.

* BTS+PBX and SIP connector+PBX  must be in the same network (UDP must be
able to flow directly between these elements)

* No handover support.

* IP based BTS (e.g. Sysmocom sysmoBTS but no Siemens BS11)

* No emergency calls