osmo-pcu/tests/edge
Aravind Sirsikar 22a901905c EGPRS: Fix issue with row 4 of Table 10.4.14a.1 of 44.060 version 7.27.0 Release 7
row 4 of Table 10.4.14a.1 of Spec 44.060 version 7.27.0 Release 7. Says
"The previous RLC data block contains a Upper Layer PDU, or a part of it,
that fills precisely the previous data block and for which there is no
length indicator in that RLC data block.
The current RLC data block contains a Upper Layer PDU that either fills
the current RLC data block precisely or continues in the next RLC data block."
So when we receive block with 1st LI: value=0 and Value of E bit in the
same octet as 1, we expect 2 chunks with 1st chunk as length as 0 and complete
and 2nd chunk as length non zero. But with this bug we see only 1 chunk causing
incorrect assembling

This issue has been fixed in this patch.

Related: OS#1811

Change-Id: I2cd0fca3ed28a553ede3f4b8a7d3267284dd2c9b
2016-09-15 17:24:49 +05:30
..
EdgeTest.cpp EGPRS: Fix issue with row 4 of Table 10.4.14a.1 of 44.060 version 7.27.0 Release 7 2016-09-15 17:24:49 +05:30
EdgeTest.ok Add test cases for Header type1 in EGPRS UL 2016-06-17 15:31:07 +00:00