It's always been the default anyway, so no need to explicitly state it.
Furthermore, recently (osmobsc 167cb828665b91ed7d28007abd4a1862ebbb78c9)
force-combined-si was enabled by default for nanoBTS due to issues with
some MS not registering when it's not enabled, so let's osmo-bsc decide
were should it be enabled.
Related: OS#3063
Change-Id: I97b10406a4a0048c66a47aa7d32a113f0c0366d1
VTY cmd "logging level all" is deprecated in favour of "logging level
set-all", but the required behaviour in this case is "logging level
set-all".
Change-Id: Ice54fca6be86f05a02ce4ae783e6e42e6958b95d
osmo-bsc c74a5616bf1c77ac40ddd92f4927dca7a1b45bc8 removed these cfg
options as they are dead code.
Change-Id: I2fb63d31d5d7424b48ed2cfc694d09db072db485
There are plenty of VTY commands that were inherited from OsmoNITB,
but which make no sense in a BSC. Upstream OsmoBSC has removed them in
change-ids Ib626f43a3a3ca69dfc127afe5832eb58f7fb6a38,
c499e5c62e9bef0db219e4658ffeb3292d6e6a5b and
8311a81bae85618302273c3f769275893161a7d7
Change-Id: I79ff48983d9cb7b875c1859870d5e3bce2c0ef22
In 3b18044859df15ffd2ad4c3e5c3d2c94a2923eb9 this command
has been dropped and is no longer recognized.
Change-Id: I98546e36f8c809e8066fe0cc0d80d0ae3276473f
authentication is firmly VLR land and must go away from bsc. That option
is a leftover from nitb. It will be removed at some point.
Change-Id: I3bb4189b33173245116018e437e113c6c1226639
As of osmo-bsc ad47f7108aff5438bd2c6f7c0e898f4aa3b66fbe, this command
has been dropped and is no longer recognized.
Change-Id: Id97074195f045e6872a1a7030671a06259c9ec31
Since Change-Id Ia2882b7ca31a3219c676986e85045fa08a425d7a, osmo-bsc
uses osmo-mgw and utilizes libosmo-mgcp-client to talk to it.
This commit fixes latest constant failures in voice suite.
Change-Id: I1dadd781a357fce33e7bde55e4bcbdaeb4633359
Before this commit, only max_power_red was specified and it could only
be used as a defaults and could not be set per object. Together with
nominal_power, it can be useful to be able to set them to different
values for different objects, as for example different osmo-bts-trx
objects can require different values.
Change-Id: I472742e98052cc39686d38c945be76d7f50eeebd
As described in https://osmocom.org/issues/2380 and related gerrit
patch https://gerrit.osmocom.org/#/c/3306 the config files currently
contain timers with a 'zero' value, leading to issues.
The config file templates used in osmo-gsm-tester suffer actually
from exactly the same issue: They basically contain values that were
written back to the file based on the default initialization in libbsc,
which unfortunately was zero in some cases.
Let's remove those values, they are the (bad) default anyway.
libbsc patches in the pipeline will introduce reasonable defaults
and forbid the use of zero for timers.
Change-Id: I8cde29a597a17c2659b3b87268be4b12975f4bef
Otherwise 127.0.0.1 was being used and we want all interfaces for a
specific osmo-bsc instance to use the same IP
Change-Id: I38dccac6707bf55f0abcf96e3a9d7d8ec765a156