the get_num_phy_errors() uses the external KPI analyzer module
to calculate the number of PHY layers errors in a vector of log metrics
Change-Id: I0c8de87e7f83f986e288585640ce56847959c497
seperate the root sequence index for each cell a bit more to
avoid detection of a single PRACH in both cells
Change-Id: I5aea1a27939c880944779c282e902465ab513715
this avoids the eNB from releasing the UE too early if the UL channel
stays very bad for a longer time but many PUSCH are scheduled
Change-Id: Ib82616e920eecc70fbded12433e54bd90ae1bcd4
this is the default TAC used in the EPC. A recent EPC patch
will reject the S1 setup request if the TACs don't match
Change-Id: I94fdb96631ce3ae35a1b2a9f90d1101df9161233
we've added the modifier to configure Amarisoft eNB channel
model. This patch enables it for srsENB.
Change-Id: I30e65d0431b2d2792986128287caf8b23a22b2c1
Power ramping features were implemented recently for osmo-bts-trx. We
don't want to enable them because it makes phones take longer (if even
at all) to find the network.
Change-Id: I35e2f560b28eddef886ad3b2f8ffb4ff79be77da
this avoids a false negative detection when the UE attach takes a bit
longer and the first seconds all zeros are reported in the CSV
the HO test, for example, would fail in such a case as it expects
no zero TP over the course of the experiment.
Change-Id: I96dab17bb19249504dedda6659aed5eac0a65a26
this gives higher UL throughput because less resources are reserved for
SR/CQI. For more users we may have to make the value configurable again.
Change-Id: If6c313a1deafffda26e9effeb807ca71064c46bc
the WS is closed if the eNB process dies. this patch will log an
event but not stop the experiment.
Change-Id: I0fafc7e38954400540375d51813e96500700f50c
report generation failed when duration was not set correctly
and None was returned. Use 0 as duration by default.
Change-Id: Ia654c67bf2dcce432f84e869550c516d8d5a07a0
we use the otherwise unused QCI 8 as a slightly modified
version of QCI 7 (default RLC UM) with a PDCP discard
timer set to infinity to avoid dropping PDCP SDUs if
packets arive faster than can be processed in the DL
Change-Id: I06b7b583701f90827fba36564f969b5d58c9b9ad
we've noticed that the Iperf client times out too soon in
some experiment. It seems that this happens with ZMQ if
the RAT is too slow (slower than realtime) and the eNB buffers
too much data. This causes iperf to still receive DL data
for example long after the configured runtime.
Change-Id: I9b823ab22812c96920d54fb7342c8d4c578d5270
same as for srsEPC this is also required for Amarisoft MME and eNB to support, i.e. 001/01
Note that the 3 digit MNC isn't covered by this.
Change-Id: I80a84e01ec9530c285634452d7c18c17bdd595ce
Since a while ago, we avoid by default using the --logfile param to log
the json output to a different file, in order to stay compatible with
older versions of iperf3.
However, the local logfile was still being created, and was not
overwritten with the remote file with content because there's none
created remotely (due to reasons explained above).
Change-Id: I218ec28dc65febc7bd083d6d15854319bf4f3daf
srsEPC expect zero-padding MNC/MCC in config file. However,
001 and mcc will end up as 1 in the rendered template.
Therefore, they need to be formatted correctly.
Change-Id: Ie63cd1b15b961e493a6dcbd7e5a4fbabe0bb6f33
when phy.signal=1 is set in the log_options, the eNB will dump
a binary file that needs to be copied back as well
Change-Id: I63d13cb74572ac065d5a3fcfb1632552d0a6dbc6
this avoids issues when the channel emulation stops in the middle
of a high attenuation values and the device is left in this state.
Change-Id: I9aeafc68bf81b8932aac4cb28040b9aea6bfcbdb
This object allows to run the "stress" cmdline program in the background
on the specifies run_node, to simulate system load.
To run stress, a test can simply do:
stress = tenv.stress(epc.run_node())
stress.start(cpu_workers=2, mem_workers=1, io_workers=1)
And the test environment will remember to stop it when the test finishes.
Change-Id: I21023e6c64c48109f294291bfe3d8d8f4e1de038
this method uses the kpi_analyzer module for analyzing
stdout, CSV metrics and the logfile (if present).
if the module can't be loaded, no KPI will be added.
Change-Id: I28226a375f9ac4e08424c488062ae6a74a19af92
New patchelf 0.11 release is out and it has fixes hitting us in both 0.9
and 0.10 on different binaries. So let's simply requiring having
patchelf 0.11 in all cases and be done with it (actually, if not running
4G binaries, using 0.9 is enough).
Related: OS#4389
Change-Id: I2701e46e7710db4c923a68e6b3a2f3c7b126f356
every call to verify_metrics would copy back metrics again. see log here:
23:29:22.149299 run srsue(pid=31521): Terminating (SIGINT)
23:29:22.368263 run srsue(pid=31521): Terminated: ok {rc=0}
23:29:28.401035 run scp-back-metrics(pid=32265): Launched
23:29:29.423083 run scp-back-metrics(pid=32265): Terminated: ok {rc=0}
23:29:29.490275 run scp-back-metrics(pid=32271): Launched
23:29:30.513852 run scp-back-metrics(pid=32271): Terminated: ok {rc=0}
23:29:30.550862 run scp-back-metrics(pid=32277): Launched
23:29:31.573962 run scp-back-metrics(pid=32277): Terminated: ok {rc=0}
this patch only copies back metrics only once. also make sure that, similar
to logs, metrics are always copied back at the end of the run even if they
are not used for metrics checking. this is needed to run the plotting
script.
Change-Id: Ie7c156a5b2c8768bf90ff8e86515976e0d454c25
In order to set up the channel emulator we need to calculate the total
number of RF channels that a eNB has from within a test.
Change-Id: If641993033eb5dcdc6e2d6afdc8426ed322241ca
this is helpful to run some action for the exact run time of an iperf3
session. note that if no time spec is given when calling
"prepare_test_proc()", a modifier could set the runtime of an DL experiment
to an arbitrary value so we need to have a mechanism to read
the actual time from within a test
Change-Id: I484a0add322ffd269a1e9df72a00cf348950b268
tests can now use 'tenv.test().set_kpis(some_dict)' to set any kind of
data as KPIs, which will be presented in the junit report.
The representation of KPIs in the xml file doesn't follow the junit
format, mainly because it has no support for per-test properties.
Change-Id: I00e976f65a202e82d440bf33708f06c8ce2643e2
10s was too short and has still caused tests to fail because they were
stopped just before the iperf finished.
30s seems to be enought and has passed multiple times so far
Change-Id: I80b732a060356aa98882ff0e8b5debaf623ba0fb
this refactor no longer enforces blocking operation of the process.
Instead it returns the process object to the caller who
can now run either proc.launch() for non-blocking operation
or proc.launch_sync() for blocking mode.
The non-block mode allos doing other stuff in the background,
for example controlling the rfemu while running a ping.
Change-Id: Ia6372e55a8829f722e40db537d9dfd63a94d1be9
Timeout value can be specified by test in suite.conf:
config:
suite:
<suite_name>:
<test_name>:
timeout: 2 # 2 seconds timeout
Change-Id: I522f51f77f8be64ebfdb5d5e07ba92baf82d7706
This feature is not really implemented and maybe never was. In any case,
it makes sense to have that working per-test so we can specify different
values per test in case it's needed.
Change-Id: I3c1b95c10e974da87ec9abd25578d8bcc0bc55a3
process object always used timeout=300 while runnig wth launch_sync().
Let's allow replacing that value beforehand so that iperf3 can
pre-configure the process object and caller doesn't need to care about
calculating expected time.
Change-Id: I7f6c5078f648013515919aa35ebcdb3ef157b5e4
Setting the log.ctx manually is not needed anymore and it's actually
harmful since all palces where it was used, a log.Origin already in path
was being passed, causing a origin loop.
Change-Id: I0511b9f7bc59e3c7f2269ff3155d0c95db58d063
Use tailored sample rate only use for 6, 50 and 75 PRB. For all other bandwidths,
we use the full LTE rate and downsample.
With 5.76e6 as base sample rate, for example, we had some issue during the tests like:
[zmq] Error: tx time is 0.178 ms in the past (7833600 < 7835648)
[zmq] Error: tx time is 0.011 ms in the past (7835520 < 7835648)
Using a higher sample rate seems to work better.
Change-Id: I53678587b2c5e0e5dccb1b55a328ad2f1a97fc4c
the overhead with 6 PRB and MIMO is a bit higher when compared
to other PRBs resulting in lower achievable throughput
Change-Id: I63888435553bba4f7be88cc745e24472921a7fb4
rename UE helper functions to query RRC connected/idle state
and adapt tests accordingly
also add helper to retrieve assinged IP address
Change-Id: I6cd057e34b4df6a1a73695355dd6406d7e039546
the default value of 60s is too long to trigger errors in the handling
of this timer. So a 5s timer is more likely to reveal potential issues
during the test execution
Change-Id: Id7a6739487c7875c4f26a47d05978c9ea9f33873
It turned out that the Amarisoft and SRS eNB scheduler produces
slightly different maximum data rates for both UL and DL.
Change-Id: I30fa7006906d101c53ba586fb06bced3945aa960
This way tests which require a very specific config file can override
specific template files used by object classes.
Change-Id: I65d1b1e826d2d430ee83810d998b98d0ccaa07cd
After this commit, in some situations ssh related errors are printed
directly in the exception to quickly find cause of the issue.
Example:
FAIL: ping.py (5.0 sec) Error: rm-remote-dir(pid=25913): launch_sync(): local ssh process exited with status 255 (ssh: connect to host 10.42.42.110 port 22: No route to host) [trial↪4g:srsue-rftype@zmq+srsenb-rftype@zmq+mod-enb-nprb@6↪ping.py:9↪ping.py↪srsepc_10.42.42.118↪host-jenkins@10.42.42.110↪rm-remote-dir(pid=25913)]
Change-Id: Ia16c7dec96f70d761600ad6a50d9df8382d9c2c8
Before, it would show somethig like:
"""
osmo_gsm_tester.core.log.Error: Exited in error 255
"""
Now:
"""
osmo_gsm_tester.core.log.Error: rm-remote-dir(pid=24820): Exited in error 255 [trial↪4g:srsue-rftype@zmq+srsenb-rftype@zmq+mod-enb-nprb@6↪ping.py:9↪ping.py↪srsepc_10.42.42.118↪host-jenkins@10.42.42.110↪rm-remote-dir(pid=24820)]
"""
Change-Id: I8873f67a2f3df21c4dd552c92510535bf95e2c9d