the default params are set for a single cell in defaults.conf
but this 2 cell config requires them to be set explicitly.
Change-Id: I8b3c486eb3e42aeb04b6a7548d3f0de2aa40ee0c
Due to the integration of DL-QAM256 another table for DL max rates is needed.
Therefore, I added the parameter 'qam256' to the feature list in the resource.cfg.
The patch also enables the correct UE settings in the config file.
Change-Id: I2d34395449cdcfb31db66ea887d9adbee551e757
change pass threshold to 80% of the max rate for
half of the testduration (rolling average).
the overall average might be lowered because of a slower
TCP start or a late UE attach.
Change-Id: I8a545b8175784e9d6b49d6bf80f637ef7aa731f7
Before this patch, almost everything was in place to support concurrent
osmo-gsm-tester instances sharing a common state dir. However, during
resource reservation, if the reservation couldn't be done due to too
many resources being in use, osmo-gsm-tester would fail and skip the
test suite.
With this patch, OGT will wait until some reserved resources are
released and then try requesting the reservation again.
Change-Id: I938602ee890712fda82fd3f812d8edb1bcd05e08
make sure to insert cell specific TAC, PCI and root seq ind
into cell config and do not depend on cell index for a particular
enb. This causes issues in multi-eNB setups.
Change-Id: I6642128a449a0562dd23f7fa393ff48ae2503006
ENB was using its own address as a remote address when the broker is
used, which actually only holds true for the first ENB (since the broker
is currently run on the same host/address of the first ENB).
Change-Id: I5c83075d140632846c6d357152963754d16b4633
The remotely run script is moved into a new subdir called "external",
where external utils to be used by osmo-gsm-tester (exernal to its own
process) are placed.
It needs to be in another directory because python files in obj/ are
loaded at startup of osmo-gsm-tester to dynamically load schemas.
Change-Id: I633a85294694f2c6efd58535729e9b8af166b3ff
It may happen that the non-emergency call MT leg is still not properly
released when the emergency call MT leg is to be assigned a TCH, meaning
BSC will fail with an Assignment Failure upon Assignment request from
MSC.
The test sometimes passed and sometimes didn't, due to above mentioned
race condition. Let's relax a bit the test expectancies to have it
always passing, while still verifying preemption happens, and MT phone
is reached.
Related: OS#4549
Change-Id: I3697227cac56a1327f9ea08c5c2f52568e8d2a8a
First step towards support everal ENBs and installing the remote script
at runtime:
* The gnuradio broker class is moved to its own file, to decouple it
from RFemu.
* The ENBs are registered earlier in the test so that the GrBroker knows
when to start (delay start + setup until all ENBs have been configured).
* Handle ENBs internally as a list.
Change-Id: I4f1095bbc7ed0a816fe47caef44f7becadd9d737
we need to use two different configs for Amarisoft and srsENB.
Amarisoft combines the two cells and transmits them on the same
RF port, whereas srsENB sends them on a single port each.
Change-Id: I3a2a8ae7bf4ed2dab6efba8550f442a741ad92e0
this patch adds the basic notion of FDD and TDD duplexing modes
to the eNB object. So far we've always assume FDD.
Since only Amarisoft eNB supports TDD, the required config
template changes, etc. are only applied there.
The patch also adds a scenario to enable the default TDD config.
Change-Id: I37216b5bfdf527d221913283b6c41d3c8fd6b500
Don't wait until adding it to the subscriber data base, since the msisdn
may be needed beforehand (for instance in follow up patch to be passed
to osmo-msc configuration to route emergency calls).
Change-Id: I0d6902687e4beb3d6cdcefd4e343f21496100504
srsENB currently creates 1 zmq stream (1 tx, 1 rx) for each cell (2 if
MIMO is enabled). Each cell transceives on a given EARFCN (and several
cells can transmit on same EARFCN).
However, for handover test purposes, we want to join all cells operating
on the same EARFCN to transceive on the same ZMQ conn, so that an srsUE
can interact with them at the same time (same as if the medium was shared).
Furthermore, we want to set different gains on each of those paths
before merging them in order to emulate RF conditions like handover.
In order to do so, a new element called the Broker is introduced, which
is placed in between ENBs and UEs ZMQ conenctions, multiplexing the
connections on the ENB side towards the UE side.
A separate process for the broker is run remotely (ENB run host) which
listens on a ctrl socket for commands. An internal Broker class is used
in osmo-gsm-tester to interact with the remote script, for instance to
configure the ports, start and stop the remote process, send commands to
it, etc.
On each ENB, when the rfemu "gnuradio_zmq" rfemu implementation is selected
in configuration, it will configure its zmq connections and the UE ones to
go over the Broker.
As a result, that means the UE zmq port configuration is expected to be
different than when no broker is in used, since there's the multiplexing
per EARFCN in between.
In this commit, only 1 ENB is supported, but multi-enb support is
planned in the future.
The handover test passes in the docker setup with this config:
"""
OSMO_GSM_TESTER_OPTS="-T -l dbg -s 4g:srsue-rftype@zmq+srsenb-rftype@zmq+" \
"mod-enb-nprb@6+mod-enb-ncells@2+mod-enb-cells-2ca+suite-4g@10,2+" \
"mod-enb-meas-enable -t =handover.py"
"""
and in resources.conf (or scenario), added:
"""
enb:
...
cell_list:
- dl_rfemu:
type: gnuradio_zmq
- dl_rfemu:
type: gnuradio_zmq
"""
Note that since the broker is used, there's not need for mod-srsue-ncarriers@2
since the broker is joining the 2 enb cells into 1 stream on the UE side.
Change-Id: I6282cda400558dcb356276786d91e6388524c5b1
The getter method was named the same as the itnernal field, and hence
when used it would fail since the intenral field would be sleect and
fail to be called.
Change-Id: I2f631eb6256eb0e065f41d5b7531395c4a054cd8
add comment explaining how the sceneario can be used.
also adopt cell IDs to match the CC index of the eNB.
This makes sure the cell_gain command of srsENB works with the config.
Change-Id: I1d14485df700ef3ba9220507f72c50b819d5e334
Otherwise osmo-trx with a B200 seems to be having issues receiving some
data from the MS otherwise, making "sms" test fail. In general LU works
fine, and when MS sends the SMS, CM Service Request+Accept also works
fine, but then the BTS never sees the CP-DATA afterwards probably due to
MS power loop.
Change-Id: I5f7e3d22a142521ab83db81635ded252dabcf111
the logic for the RF emulator on the command line is, like the
Amarisoft equivalent, to set a negative gain value to express
attenuation. Therefore, the sign needs to be inverted.
Change-Id: I7b6ac611a9f711bbdc1570602bfd797a5346ab86
So far we only support setting cell IDs from same ENB. Support for
handover to other ENB will come later, probably by adding some API to be
called during the test to add own's CellID's to other ENB's config.t
Change-Id: I1780bda130cde0faab15d4032117e0aa2b9c5dbe
pass-through the option so they can be used in templates
just concatenate with rf_dev_args for srsLTE eNB/UE, arguments
parsing will handle them
Change-Id: I3818026c159780f29968888f547163cdf730afad
newer versions of srsLTE create symlinks with the rf library
including the version, see below. This caused the trx_zmq.so
lib to load .so.0 instead of .so only. this patch adds
another symlink so loading works fine again
libsrslte_rf.so -> libsrslte_rf.so.0
libsrslte_rf.so.0 -> libsrslte_rf.so.20.10.0
libsrslte_rf.so.20.10.0
Change-Id: Ib5302c9872f4c82a1ee5074f59de86709aa6c5a9
the get_num_phy_errors() uses the external KPI analyzer module
to calculate the number of PHY layers errors in a vector of log metrics
Change-Id: I0c8de87e7f83f986e288585640ce56847959c497
seperate the root sequence index for each cell a bit more to
avoid detection of a single PRACH in both cells
Change-Id: I5aea1a27939c880944779c282e902465ab513715
this avoids the eNB from releasing the UE too early if the UL channel
stays very bad for a longer time but many PUSCH are scheduled
Change-Id: Ib82616e920eecc70fbded12433e54bd90ae1bcd4
this is the default TAC used in the EPC. A recent EPC patch
will reject the S1 setup request if the TACs don't match
Change-Id: I94fdb96631ce3ae35a1b2a9f90d1101df9161233