suites: 4g: Parametrize handover.py test

Change-Id: I7de5acdaa6b905e52655786758bd51490add1d2b
This commit is contained in:
Pau Espin 2020-05-06 21:11:39 +02:00 committed by pespin
parent 306373027a
commit fa02b9c677
3 changed files with 47 additions and 19 deletions

View File

@ -0,0 +1,6 @@
config:
suite:
4g:
handover:
duration: ${param1}
threshold: ${param2}

View File

@ -1,10 +1,32 @@
#!/usr/bin/env python3
from osmo_gsm_tester.testenv import *
epc = suite.epc()
enb = suite.enb()
ue = suite.modem()
iperf3srv = suite.iperf3srv({'addr': epc.tun_addr()})
import time
test_config = tenv.config_test_specific()
duration = int(test_config.get('duration', 0)) # 0 = one HO loop
threshold = int(test_config.get('threshold', 2))
import pprint
print("TEST_CONFIG:\n" + pprint.pformat(test_config))
# attenuation from 0 to 10, then back to 0
cell1_att_li = list(range(0, 11, 1)) + list(range(9, -1, -1))
# attenuation from 10 to 0, then back to 10
cell2_att_li = list(range(10, 0, -1)) + list(range(0, 11, 1))
def do_one_ho_loop(rfemu_cell1, rfemu_cell2):
step = 0
while step < len(cell1_att_li):
rfemu_cell1.set_attenuation(cell1_att_li[step])
rfemu_cell2.set_attenuation(cell2_att_li[step])
step += 1
sleep(1)
epc = tenv.epc()
enb = tenv.enb()
ue = tenv.modem()
iperf3srv = tenv.iperf3srv({'addr': epc.tun_addr()})
iperf3srv.set_run_node(epc.run_node())
iperf3cli = iperf3srv.create_client()
iperf3cli.set_run_node(ue.run_node())
@ -21,7 +43,7 @@ print('ENB is connected to EPC')
ue.connect(enb)
iperf3srv.start()
proc = iperf3cli.prepare_test_proc(False, ue.netns(), 30)
proc = iperf3cli.prepare_test_proc(False, ue.netns(), duration + 30)
print('waiting for UE to attach...')
wait(ue.is_connected, None)
@ -30,22 +52,17 @@ print('UE is attached')
rfemu_cell1 = enb.get_rfemu(0)
rfemu_cell2 = enb.get_rfemu(1)
# attenuation from 0 to 10, then back to 0
cell1_att_li = list(range(0, 11, 1)) + list(range(9, -1, -1))
# attenuation from 10 to 0, then back to 10
cell2_att_li = list(range(10, 0, -1)) + list(range(0, 11, 1))
print('Iterating for %d seconds to produce at least %d handovers...' % (duration, threshold))
try:
proc.launch()
step = 0
while step < len(cell1_att_li):
rfemu_cell1.set_attenuation(cell1_att_li[step])
rfemu_cell2.set_attenuation(cell2_att_li[step])
step += 1
sleep(1)
t_end = time.time() + duration
if duration == 0:
t_end += 1 # allow loop to run once
while time.time() < t_end:
do_one_ho_loop(rfemu_cell1, rfemu_cell2)
num_handovers = ue.get_counter('handover_success')
if num_handovers != 2:
raise Exception('Wrong number of handovers %d vs expected 2' % num_handovers)
if num_handovers < threshold:
raise Exception('Wrong number of handovers %d < threshold %d during %d seconds' % (num_handovers, threshold, duration))
except Exception as e:
try:
proc.terminate() # make sure we always terminate the process
@ -53,7 +70,7 @@ except Exception as e:
print("Exception while terminating process %r" % repr(process))
raise e
rest_str = 'Got %d successful handovers' % num_handovers
rest_str = 'Got %d successful handovers (>= %d) during %d seconds' % (num_handovers, threshold, duration)
print(res_str)
test.set_report_stdout(res_str)
proc.terminate()

View File

@ -8,5 +8,10 @@ resources:
features:
- 4g
schema:
handover:
duration: 'duration'
threshold: 'uint'
defaults:
timeout: 180s