2017-03-28 10:16:58 +00:00
|
|
|
#!/usr/bin/env python3
|
|
|
|
|
2020-05-07 17:32:21 +00:00
|
|
|
# osmo-gsm-tester.py: main program file
|
2017-03-28 10:16:58 +00:00
|
|
|
#
|
2020-05-07 17:32:21 +00:00
|
|
|
# Copyright (C) 2016-2020 sysmocom - s.f.m.c. GmbH <info@sysmocom.de>
|
2017-03-28 10:16:58 +00:00
|
|
|
#
|
|
|
|
# Author: Neels Hofmeyr <neels@hofmeyr.de>
|
2020-05-07 17:32:21 +00:00
|
|
|
# Author: Pau Espin Pedrol <pespin@sysmocom.de>
|
2017-03-28 10:16:58 +00:00
|
|
|
#
|
|
|
|
# This program is free software: you can redistribute it and/or modify
|
2017-06-03 07:51:45 +00:00
|
|
|
# it under the terms of the GNU General Public License as
|
2017-03-28 10:16:58 +00:00
|
|
|
# published by the Free Software Foundation, either version 3 of the
|
|
|
|
# License, or (at your option) any later version.
|
|
|
|
#
|
|
|
|
# This program is distributed in the hope that it will be useful,
|
|
|
|
# but WITHOUT ANY WARRANTY; without even the implied warranty of
|
|
|
|
# MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
|
2017-06-03 07:51:45 +00:00
|
|
|
# GNU General Public License for more details.
|
2017-03-28 10:16:58 +00:00
|
|
|
#
|
2017-06-03 07:51:45 +00:00
|
|
|
# You should have received a copy of the GNU General Public License
|
2017-03-28 10:16:58 +00:00
|
|
|
# along with this program. If not, see <http://www.gnu.org/licenses/>.
|
|
|
|
|
2020-05-07 17:32:21 +00:00
|
|
|
'''osmo-gsm-tester.py: invoke a single test run
|
2017-03-28 10:16:58 +00:00
|
|
|
|
2017-03-28 12:30:28 +00:00
|
|
|
Examples:
|
2017-03-28 10:16:58 +00:00
|
|
|
|
2020-05-11 16:30:58 +00:00
|
|
|
./osmo-gsm-tester.py -c doc/examples/2g_osmocom/main.conf ~/my_trial_package/ -s osmo_trx
|
|
|
|
./osmo-gsm-tester.py -c doc/examples/2g_osmocom/main.conf ~/my_trial_package/ -s sms_tests:dyn_ts+eu_band+bts_sysmo
|
|
|
|
./osmo-gsm-tester.py -c sysmocom/main.conf ~/my_trial_package/ -s sms_tests/mo_mt_sms:bts_trx
|
2017-03-28 12:30:28 +00:00
|
|
|
|
2020-05-07 17:32:21 +00:00
|
|
|
(The names for test suites and scenarios used in these examples must be defined
|
|
|
|
by the osmo-gsm-tester configuration.)
|
2017-03-28 12:30:28 +00:00
|
|
|
|
2020-05-07 17:32:21 +00:00
|
|
|
A trial package contains binaries (usually built by a jenkins job) of software
|
|
|
|
to be run by Osmo-Gsm-Tester, like core network programs as well as binaries for
|
|
|
|
the various BTS models on a 2G network.
|
2017-03-28 12:30:28 +00:00
|
|
|
|
|
|
|
A test suite defines specific actions to be taken and verifies their outcome.
|
|
|
|
Such a test suite may leave certain aspects of a setup undefined, e.g. it may
|
|
|
|
be BTS model agnostic or does not care which voice codecs are chosen.
|
|
|
|
|
|
|
|
A test scenario completes the picture in that it defines which specific choices
|
|
|
|
shall be made to run a test suite. Any one test suite may thus run on any
|
|
|
|
number of different scenarios, e.g. to test various voice codecs.
|
|
|
|
|
|
|
|
Test scenarios may be combined. For example, one scenario may define a timeslot
|
|
|
|
configuration to use, while another scenario may define the voice codec
|
|
|
|
configuration.
|
|
|
|
|
|
|
|
There may still be aspects that are neither required by a test suite nor
|
|
|
|
strictly defined by a scenario, which will be resolved automatically, e.g. by
|
|
|
|
choosing the first available item that matches the other constraints.
|
|
|
|
|
2020-05-07 17:32:21 +00:00
|
|
|
A test run thus needs to define:
|
|
|
|
* A trial package containing built binaries
|
|
|
|
* A set of test suites, each with its combinations of scenarios
|
2020-05-11 16:30:58 +00:00
|
|
|
* A main configuration file specifying paths to other files containing sets of
|
|
|
|
resources, default configurations and paths on where to find suites,
|
|
|
|
scenarios, etc.
|
2017-03-28 12:30:28 +00:00
|
|
|
|
2020-05-07 17:32:21 +00:00
|
|
|
If no combination of suites and scenarios is provided, the default list of
|
|
|
|
suites will be run as defined in the osmo-gsm-tester configuration.
|
2017-03-28 12:30:28 +00:00
|
|
|
|
|
|
|
The scenarios and suites run for a given trial will be recorded in a trial
|
2020-05-07 17:32:21 +00:00
|
|
|
package's directory: Upon launch, a '$trial_dir/run.<date>' directory will be
|
2017-03-28 12:30:28 +00:00
|
|
|
created, which will collect logs and reports.
|
2017-03-28 10:16:58 +00:00
|
|
|
'''
|
|
|
|
|
2017-04-08 19:18:30 +00:00
|
|
|
import sys
|
2017-05-14 01:05:48 +00:00
|
|
|
import argparse
|
2017-05-17 12:51:31 +00:00
|
|
|
from signal import *
|
2017-04-08 13:56:31 +00:00
|
|
|
from osmo_gsm_tester import __version__
|
2020-05-04 10:05:05 +00:00
|
|
|
from osmo_gsm_tester.core import log
|
2020-05-05 10:18:35 +00:00
|
|
|
from osmo_gsm_tester.core import trial
|
|
|
|
from osmo_gsm_tester.core import suite
|
2020-05-06 12:04:18 +00:00
|
|
|
from osmo_gsm_tester.core import config
|
2020-05-04 10:05:05 +00:00
|
|
|
from osmo_gsm_tester.core.schema import generate_schemas
|
2017-03-28 10:16:58 +00:00
|
|
|
|
2017-05-17 12:51:31 +00:00
|
|
|
def sig_handler_cleanup(signum, frame):
|
|
|
|
print("killed by signal %d" % signum)
|
|
|
|
# This sys.exit() will raise a SystemExit base exception at the current
|
|
|
|
# point of execution. Code must be prepared to clean system-wide resources
|
|
|
|
# by using the "finally" section. This allows at the end 'atexit' hooks to
|
|
|
|
# be called before exiting.
|
|
|
|
sys.exit(1)
|
|
|
|
|
2017-05-14 01:00:21 +00:00
|
|
|
def main():
|
2017-03-28 10:16:58 +00:00
|
|
|
|
2017-05-17 12:51:31 +00:00
|
|
|
for sig in (SIGINT, SIGTERM, SIGQUIT, SIGPIPE, SIGHUP):
|
|
|
|
signal(sig, sig_handler_cleanup)
|
|
|
|
|
2017-03-28 12:30:28 +00:00
|
|
|
parser = argparse.ArgumentParser(epilog=__doc__, formatter_class=argparse.RawTextHelpFormatter)
|
2017-05-06 20:07:39 +00:00
|
|
|
# Note: since we're using RawTextHelpFormatter to keep nicely separate
|
|
|
|
# paragraphs in the long help text, we unfortunately also need to take care
|
|
|
|
# of line wraps in the shorter cmdline options help.
|
|
|
|
# The line width here is what remains of screen width after the list of
|
|
|
|
# options placed by ArgumentParser. That's unfortunately subject to change
|
|
|
|
# and undefined, so when things change, just run a local
|
|
|
|
# ./osmo-gsm-tester.py --help and try to keep everything in 80 chars width.
|
|
|
|
# The help text is indented automatically, but line width is manual.
|
|
|
|
# Using multi-line strings here -- doesn't look nice in the python flow but
|
|
|
|
# is easiest to maintain.
|
2017-03-28 10:16:58 +00:00
|
|
|
parser.add_argument('-V', '--version', action='store_true',
|
|
|
|
help='Show version')
|
2020-05-11 16:30:58 +00:00
|
|
|
parser.add_argument('-c', '--conf-path', dest='conf_path',
|
|
|
|
help='''Specify main configuration file path''')
|
refactor: fix error handling; fix log.Origin; only one trial
A bit of refactoring to fix logging and error reporting, and simplify the code.
This transmogrifies some of the things committed in
0ffb41440661631fa1d520c152be4cf8ebd4c46b "Add JUnit XML reports; refactor test
reporting", which did not fully match the code structuring ideas used in
osmo-gsm-tester. Also solve some problems present from the start of the code
base.
Though this is a bit of a code bomb, it would take a lot of time to separate
this into smaller bits: these changes are closely related and resulted
incrementally from testing error handling and logging details. I hope it's ok.
Things changed / problems fixed:
Allow only a single trial to be run per cmdline invocation: unbloat trial and
suite invocation in osmo-gsm-tester.py.
There is a SuiteDefinition, intended to be immutable, and a mutable SuiteRun.
SuiteDefinition had a list of tests, which was modified by the SuiteRun to
record test results. Instead, have only the test basenames in the
SuiteDefinition and create a new set of Test() instances for each SuiteRun, to
ensure that no state leaks between separate suite runs.
State leaking across runs can be seen in
http://jenkins.osmocom.org/jenkins/view/osmo-gsm-tester/job/osmo-gsm-tester_run/453/
where an earlier sms test for sysmo succeeds, but its state gets overwritten by
the later sms test for trx that fails. The end result is that both tests
failed, although the first run was successful.
Fix a problem with Origin: log.Origin allowed to be __enter__ed more than once,
skipping the second entry. The problem there is that we'd still __exit__ twice
or more, popping the Origin off the stack even though it should still remain.
We could count __enter__ recurrences, but instead, completely disallow entering
a second time.
A code path should have one 'with' statement per object, at pivotal points like
run_suites or run_tests. Individual utility functions should not do 'with' on a
central object. The structure needed is, in pseudo code:
try:
with trial:
try:
with suite_run:
try:
with test:
test_actions()
The 'with' needs to be inside the 'try', so that the exception can be handled
in __exit__ before it reaches the exception logging.
To clarify this, like test exceptions caught in Test.run(), also move suite
exception handling from Trial into SuiteRun.run_tests(). There are 'with self'
in Test.run() and SuiteRun.run_tests(), which are well placed, because these
are pivotal points in the main code path.
Log output: clearly separate logging of distinct suites and test scripts, by
adding more large_separator() calls at the start of each test. Place these
separator calls in more logical places. Add separator size and spacing args.
Log output: print tracebacks only once, for the test script where they happen.
Have less state that duplicates other state: drop SuiteRun.test_failed_ctr and
suite.test_skipped_ctr, instead add SuiteRun.count_test_results().
For test failure reporting, store the traceback text in a separate member var.
In the text report, apply above changes and unclutter to achieve a brief and
easy to read result overview: print less filler characters, drop the starting
times, drop the tracebacks. This can be found in the individual test logs.
Because the tracebacks are no longer in the text report, the suite_test.py can
just print the reports and expect that output instead of asserting individual
contents.
In the text report, print duration in precision of .1 seconds.
Add origin information and a traceback text to the junit XML result to give
more context when browsing the result XML. For 'AssertionError', add the source
line of where the assertion hit.
Drop the explicit Failure exception. We don't need one specific exception to
mark a failure, instead any arbitrary exception is treated as a failure. Use
the exception's class name as fail_type.
Though my original idea was to use raising exceptions as the only way to cause
a test failure, I'm keeping the set_fail() function as an alternative way,
because it allows test specific cleanup and may come in handy later. To have
both ways integrate seamlessly, shift some result setting into 'finally'
clauses and make sure higher levels (suite, trial) count the contained items'
stati.
Minor tweak: write the 'pass' and 'skip' reports in lower case so that the
'FAIL' stands out.
Minor tweak: pass the return code that the program exit should return further
outward, so that the exit(1) call does not cause a SystemExit exception to be
logged.
The aims of this patch are:
- Logs are readable so that it is clear which logging belongs to which test and
suite.
- The logging origins are correct (vs. parents gone missing as previously)
- A single test error does not cause following tests or suites to be skipped.
- An exception "above" Exception, i.e. SystemExit and the like, *does*
immediately abort all tests and suites, and the results for tests that were
not run are reported as "unknown" (rather than skipped on purpose):
- Raising a SystemExit aborts all.
- Hitting ctrl-c aborts all.
- The resulting summary in the log is brief and readable.
Change-Id: Ibf0846d457cab26f54c25e6906a8bb304724e2d8
2017-06-06 17:41:17 +00:00
|
|
|
parser.add_argument('trial_package',
|
2017-03-28 10:16:58 +00:00
|
|
|
help='Directory containing binaries to test')
|
2017-03-28 12:30:28 +00:00
|
|
|
parser.add_argument('-s', '--suite-scenario', dest='suite_scenario', action='append',
|
2017-05-06 20:07:39 +00:00
|
|
|
help='''A suite-scenarios combination
|
|
|
|
like suite:scenario+scenario''')
|
2017-03-28 12:30:28 +00:00
|
|
|
parser.add_argument('-t', '--test', dest='test', action='append',
|
2017-05-06 20:07:39 +00:00
|
|
|
help='''Run only tests matching this name.
|
|
|
|
Any test name that contains the given string is run.
|
|
|
|
To get an exact match, prepend a "=" like
|
|
|
|
"-t =my_exact_name". The ".py" suffix is always
|
|
|
|
optional.''')
|
2017-03-28 12:30:28 +00:00
|
|
|
parser.add_argument('-l', '--log-level', dest='log_level', choices=log.LEVEL_STRS.keys(),
|
|
|
|
default=None,
|
|
|
|
help='Set logging level for all categories (on stdout)')
|
|
|
|
parser.add_argument('-T', '--traceback', dest='trace', action='store_true',
|
2017-06-06 17:41:42 +00:00
|
|
|
help='Enable stdout logging of tracebacks')
|
|
|
|
parser.add_argument('-R', '--source', dest='source', action='store_true',
|
|
|
|
help='Enable stdout logging of source file')
|
2017-03-28 10:16:58 +00:00
|
|
|
args = parser.parse_args()
|
|
|
|
|
|
|
|
if args.version:
|
2017-03-28 12:30:28 +00:00
|
|
|
print(__version__)
|
2017-03-28 10:16:58 +00:00
|
|
|
exit(0)
|
|
|
|
|
2017-03-28 12:30:28 +00:00
|
|
|
print('combinations:', repr(args.suite_scenario))
|
refactor: fix error handling; fix log.Origin; only one trial
A bit of refactoring to fix logging and error reporting, and simplify the code.
This transmogrifies some of the things committed in
0ffb41440661631fa1d520c152be4cf8ebd4c46b "Add JUnit XML reports; refactor test
reporting", which did not fully match the code structuring ideas used in
osmo-gsm-tester. Also solve some problems present from the start of the code
base.
Though this is a bit of a code bomb, it would take a lot of time to separate
this into smaller bits: these changes are closely related and resulted
incrementally from testing error handling and logging details. I hope it's ok.
Things changed / problems fixed:
Allow only a single trial to be run per cmdline invocation: unbloat trial and
suite invocation in osmo-gsm-tester.py.
There is a SuiteDefinition, intended to be immutable, and a mutable SuiteRun.
SuiteDefinition had a list of tests, which was modified by the SuiteRun to
record test results. Instead, have only the test basenames in the
SuiteDefinition and create a new set of Test() instances for each SuiteRun, to
ensure that no state leaks between separate suite runs.
State leaking across runs can be seen in
http://jenkins.osmocom.org/jenkins/view/osmo-gsm-tester/job/osmo-gsm-tester_run/453/
where an earlier sms test for sysmo succeeds, but its state gets overwritten by
the later sms test for trx that fails. The end result is that both tests
failed, although the first run was successful.
Fix a problem with Origin: log.Origin allowed to be __enter__ed more than once,
skipping the second entry. The problem there is that we'd still __exit__ twice
or more, popping the Origin off the stack even though it should still remain.
We could count __enter__ recurrences, but instead, completely disallow entering
a second time.
A code path should have one 'with' statement per object, at pivotal points like
run_suites or run_tests. Individual utility functions should not do 'with' on a
central object. The structure needed is, in pseudo code:
try:
with trial:
try:
with suite_run:
try:
with test:
test_actions()
The 'with' needs to be inside the 'try', so that the exception can be handled
in __exit__ before it reaches the exception logging.
To clarify this, like test exceptions caught in Test.run(), also move suite
exception handling from Trial into SuiteRun.run_tests(). There are 'with self'
in Test.run() and SuiteRun.run_tests(), which are well placed, because these
are pivotal points in the main code path.
Log output: clearly separate logging of distinct suites and test scripts, by
adding more large_separator() calls at the start of each test. Place these
separator calls in more logical places. Add separator size and spacing args.
Log output: print tracebacks only once, for the test script where they happen.
Have less state that duplicates other state: drop SuiteRun.test_failed_ctr and
suite.test_skipped_ctr, instead add SuiteRun.count_test_results().
For test failure reporting, store the traceback text in a separate member var.
In the text report, apply above changes and unclutter to achieve a brief and
easy to read result overview: print less filler characters, drop the starting
times, drop the tracebacks. This can be found in the individual test logs.
Because the tracebacks are no longer in the text report, the suite_test.py can
just print the reports and expect that output instead of asserting individual
contents.
In the text report, print duration in precision of .1 seconds.
Add origin information and a traceback text to the junit XML result to give
more context when browsing the result XML. For 'AssertionError', add the source
line of where the assertion hit.
Drop the explicit Failure exception. We don't need one specific exception to
mark a failure, instead any arbitrary exception is treated as a failure. Use
the exception's class name as fail_type.
Though my original idea was to use raising exceptions as the only way to cause
a test failure, I'm keeping the set_fail() function as an alternative way,
because it allows test specific cleanup and may come in handy later. To have
both ways integrate seamlessly, shift some result setting into 'finally'
clauses and make sure higher levels (suite, trial) count the contained items'
stati.
Minor tweak: write the 'pass' and 'skip' reports in lower case so that the
'FAIL' stands out.
Minor tweak: pass the return code that the program exit should return further
outward, so that the exit(1) call does not cause a SystemExit exception to be
logged.
The aims of this patch are:
- Logs are readable so that it is clear which logging belongs to which test and
suite.
- The logging origins are correct (vs. parents gone missing as previously)
- A single test error does not cause following tests or suites to be skipped.
- An exception "above" Exception, i.e. SystemExit and the like, *does*
immediately abort all tests and suites, and the results for tests that were
not run are reported as "unknown" (rather than skipped on purpose):
- Raising a SystemExit aborts all.
- Hitting ctrl-c aborts all.
- The resulting summary in the log is brief and readable.
Change-Id: Ibf0846d457cab26f54c25e6906a8bb304724e2d8
2017-06-06 17:41:17 +00:00
|
|
|
print('trial:', repr(args.trial_package))
|
2017-03-28 12:30:28 +00:00
|
|
|
print('tests:', repr(args.test))
|
|
|
|
|
2017-05-05 17:48:35 +00:00
|
|
|
# create a default log to stdout
|
2017-05-24 16:31:01 +00:00
|
|
|
log.LogTarget().style(all_origins_on_levels=(log.L_ERR, log.L_TRACEBACK), src=False)
|
2017-05-05 17:48:35 +00:00
|
|
|
|
2017-03-28 12:30:28 +00:00
|
|
|
if args.log_level:
|
|
|
|
log.set_all_levels(log.LEVEL_STRS.get(args.log_level))
|
|
|
|
if args.trace:
|
|
|
|
log.style_change(trace=True)
|
2017-06-06 17:41:42 +00:00
|
|
|
if args.source:
|
|
|
|
log.style_change(src=True)
|
2020-05-11 16:30:58 +00:00
|
|
|
if args.conf_path:
|
|
|
|
config.override_conf = args.conf_path
|
2017-03-28 12:30:28 +00:00
|
|
|
|
|
|
|
combination_strs = list(args.suite_scenario or [])
|
|
|
|
|
2017-04-08 13:56:31 +00:00
|
|
|
if not combination_strs:
|
2020-05-11 16:30:58 +00:00
|
|
|
combination_strs = config.read_config_file(config.CFG_DEFAULT_SUITES_CONF, if_missing_return=[])
|
2017-04-08 13:56:31 +00:00
|
|
|
|
|
|
|
if combination_strs:
|
|
|
|
print('Running default suites:\n ' + ('\n '.join(combination_strs)))
|
2017-04-08 16:52:39 +00:00
|
|
|
else:
|
2020-05-11 16:30:58 +00:00
|
|
|
print('Failed to load default suites (%r)' % config.get_main_config_value(config.DEFAULT_SUITES_CONF, fail_if_missing=False))
|
2017-04-08 16:52:39 +00:00
|
|
|
|
2017-04-08 13:56:31 +00:00
|
|
|
|
2017-03-28 12:30:28 +00:00
|
|
|
if not combination_strs:
|
2020-05-07 17:32:21 +00:00
|
|
|
raise RuntimeError('Need at least one suite:scenario to run')
|
2017-03-28 12:30:28 +00:00
|
|
|
|
2020-05-04 10:05:05 +00:00
|
|
|
# Generate supported schemas dynamically from objects:
|
|
|
|
generate_schemas()
|
|
|
|
|
refactor: fix error handling; fix log.Origin; only one trial
A bit of refactoring to fix logging and error reporting, and simplify the code.
This transmogrifies some of the things committed in
0ffb41440661631fa1d520c152be4cf8ebd4c46b "Add JUnit XML reports; refactor test
reporting", which did not fully match the code structuring ideas used in
osmo-gsm-tester. Also solve some problems present from the start of the code
base.
Though this is a bit of a code bomb, it would take a lot of time to separate
this into smaller bits: these changes are closely related and resulted
incrementally from testing error handling and logging details. I hope it's ok.
Things changed / problems fixed:
Allow only a single trial to be run per cmdline invocation: unbloat trial and
suite invocation in osmo-gsm-tester.py.
There is a SuiteDefinition, intended to be immutable, and a mutable SuiteRun.
SuiteDefinition had a list of tests, which was modified by the SuiteRun to
record test results. Instead, have only the test basenames in the
SuiteDefinition and create a new set of Test() instances for each SuiteRun, to
ensure that no state leaks between separate suite runs.
State leaking across runs can be seen in
http://jenkins.osmocom.org/jenkins/view/osmo-gsm-tester/job/osmo-gsm-tester_run/453/
where an earlier sms test for sysmo succeeds, but its state gets overwritten by
the later sms test for trx that fails. The end result is that both tests
failed, although the first run was successful.
Fix a problem with Origin: log.Origin allowed to be __enter__ed more than once,
skipping the second entry. The problem there is that we'd still __exit__ twice
or more, popping the Origin off the stack even though it should still remain.
We could count __enter__ recurrences, but instead, completely disallow entering
a second time.
A code path should have one 'with' statement per object, at pivotal points like
run_suites or run_tests. Individual utility functions should not do 'with' on a
central object. The structure needed is, in pseudo code:
try:
with trial:
try:
with suite_run:
try:
with test:
test_actions()
The 'with' needs to be inside the 'try', so that the exception can be handled
in __exit__ before it reaches the exception logging.
To clarify this, like test exceptions caught in Test.run(), also move suite
exception handling from Trial into SuiteRun.run_tests(). There are 'with self'
in Test.run() and SuiteRun.run_tests(), which are well placed, because these
are pivotal points in the main code path.
Log output: clearly separate logging of distinct suites and test scripts, by
adding more large_separator() calls at the start of each test. Place these
separator calls in more logical places. Add separator size and spacing args.
Log output: print tracebacks only once, for the test script where they happen.
Have less state that duplicates other state: drop SuiteRun.test_failed_ctr and
suite.test_skipped_ctr, instead add SuiteRun.count_test_results().
For test failure reporting, store the traceback text in a separate member var.
In the text report, apply above changes and unclutter to achieve a brief and
easy to read result overview: print less filler characters, drop the starting
times, drop the tracebacks. This can be found in the individual test logs.
Because the tracebacks are no longer in the text report, the suite_test.py can
just print the reports and expect that output instead of asserting individual
contents.
In the text report, print duration in precision of .1 seconds.
Add origin information and a traceback text to the junit XML result to give
more context when browsing the result XML. For 'AssertionError', add the source
line of where the assertion hit.
Drop the explicit Failure exception. We don't need one specific exception to
mark a failure, instead any arbitrary exception is treated as a failure. Use
the exception's class name as fail_type.
Though my original idea was to use raising exceptions as the only way to cause
a test failure, I'm keeping the set_fail() function as an alternative way,
because it allows test specific cleanup and may come in handy later. To have
both ways integrate seamlessly, shift some result setting into 'finally'
clauses and make sure higher levels (suite, trial) count the contained items'
stati.
Minor tweak: write the 'pass' and 'skip' reports in lower case so that the
'FAIL' stands out.
Minor tweak: pass the return code that the program exit should return further
outward, so that the exit(1) call does not cause a SystemExit exception to be
logged.
The aims of this patch are:
- Logs are readable so that it is clear which logging belongs to which test and
suite.
- The logging origins are correct (vs. parents gone missing as previously)
- A single test error does not cause following tests or suites to be skipped.
- An exception "above" Exception, i.e. SystemExit and the like, *does*
immediately abort all tests and suites, and the results for tests that were
not run are reported as "unknown" (rather than skipped on purpose):
- Raising a SystemExit aborts all.
- Hitting ctrl-c aborts all.
- The resulting summary in the log is brief and readable.
Change-Id: Ibf0846d457cab26f54c25e6906a8bb304724e2d8
2017-06-06 17:41:17 +00:00
|
|
|
# make sure all suite:scenarios exist
|
2017-03-28 12:30:28 +00:00
|
|
|
suite_scenarios = []
|
|
|
|
for combination_str in combination_strs:
|
|
|
|
suite_scenarios.append(suite.load_suite_scenario_str(combination_str))
|
|
|
|
|
refactor: fix error handling; fix log.Origin; only one trial
A bit of refactoring to fix logging and error reporting, and simplify the code.
This transmogrifies some of the things committed in
0ffb41440661631fa1d520c152be4cf8ebd4c46b "Add JUnit XML reports; refactor test
reporting", which did not fully match the code structuring ideas used in
osmo-gsm-tester. Also solve some problems present from the start of the code
base.
Though this is a bit of a code bomb, it would take a lot of time to separate
this into smaller bits: these changes are closely related and resulted
incrementally from testing error handling and logging details. I hope it's ok.
Things changed / problems fixed:
Allow only a single trial to be run per cmdline invocation: unbloat trial and
suite invocation in osmo-gsm-tester.py.
There is a SuiteDefinition, intended to be immutable, and a mutable SuiteRun.
SuiteDefinition had a list of tests, which was modified by the SuiteRun to
record test results. Instead, have only the test basenames in the
SuiteDefinition and create a new set of Test() instances for each SuiteRun, to
ensure that no state leaks between separate suite runs.
State leaking across runs can be seen in
http://jenkins.osmocom.org/jenkins/view/osmo-gsm-tester/job/osmo-gsm-tester_run/453/
where an earlier sms test for sysmo succeeds, but its state gets overwritten by
the later sms test for trx that fails. The end result is that both tests
failed, although the first run was successful.
Fix a problem with Origin: log.Origin allowed to be __enter__ed more than once,
skipping the second entry. The problem there is that we'd still __exit__ twice
or more, popping the Origin off the stack even though it should still remain.
We could count __enter__ recurrences, but instead, completely disallow entering
a second time.
A code path should have one 'with' statement per object, at pivotal points like
run_suites or run_tests. Individual utility functions should not do 'with' on a
central object. The structure needed is, in pseudo code:
try:
with trial:
try:
with suite_run:
try:
with test:
test_actions()
The 'with' needs to be inside the 'try', so that the exception can be handled
in __exit__ before it reaches the exception logging.
To clarify this, like test exceptions caught in Test.run(), also move suite
exception handling from Trial into SuiteRun.run_tests(). There are 'with self'
in Test.run() and SuiteRun.run_tests(), which are well placed, because these
are pivotal points in the main code path.
Log output: clearly separate logging of distinct suites and test scripts, by
adding more large_separator() calls at the start of each test. Place these
separator calls in more logical places. Add separator size and spacing args.
Log output: print tracebacks only once, for the test script where they happen.
Have less state that duplicates other state: drop SuiteRun.test_failed_ctr and
suite.test_skipped_ctr, instead add SuiteRun.count_test_results().
For test failure reporting, store the traceback text in a separate member var.
In the text report, apply above changes and unclutter to achieve a brief and
easy to read result overview: print less filler characters, drop the starting
times, drop the tracebacks. This can be found in the individual test logs.
Because the tracebacks are no longer in the text report, the suite_test.py can
just print the reports and expect that output instead of asserting individual
contents.
In the text report, print duration in precision of .1 seconds.
Add origin information and a traceback text to the junit XML result to give
more context when browsing the result XML. For 'AssertionError', add the source
line of where the assertion hit.
Drop the explicit Failure exception. We don't need one specific exception to
mark a failure, instead any arbitrary exception is treated as a failure. Use
the exception's class name as fail_type.
Though my original idea was to use raising exceptions as the only way to cause
a test failure, I'm keeping the set_fail() function as an alternative way,
because it allows test specific cleanup and may come in handy later. To have
both ways integrate seamlessly, shift some result setting into 'finally'
clauses and make sure higher levels (suite, trial) count the contained items'
stati.
Minor tweak: write the 'pass' and 'skip' reports in lower case so that the
'FAIL' stands out.
Minor tweak: pass the return code that the program exit should return further
outward, so that the exit(1) call does not cause a SystemExit exception to be
logged.
The aims of this patch are:
- Logs are readable so that it is clear which logging belongs to which test and
suite.
- The logging origins are correct (vs. parents gone missing as previously)
- A single test error does not cause following tests or suites to be skipped.
- An exception "above" Exception, i.e. SystemExit and the like, *does*
immediately abort all tests and suites, and the results for tests that were
not run are reported as "unknown" (rather than skipped on purpose):
- Raising a SystemExit aborts all.
- Hitting ctrl-c aborts all.
- The resulting summary in the log is brief and readable.
Change-Id: Ibf0846d457cab26f54c25e6906a8bb304724e2d8
2017-06-06 17:41:17 +00:00
|
|
|
# pick tests and make sure they exist
|
2017-03-28 12:30:28 +00:00
|
|
|
test_names = []
|
|
|
|
for test_name in (args.test or []):
|
|
|
|
found = False
|
2017-05-06 14:04:37 +00:00
|
|
|
if test_name.startswith('=') and not test_name.endswith('.py'):
|
|
|
|
test_name = test_name + '.py'
|
2017-05-06 13:49:53 +00:00
|
|
|
for suite_scenario_str, suite_def, scenarios in suite_scenarios:
|
refactor: fix error handling; fix log.Origin; only one trial
A bit of refactoring to fix logging and error reporting, and simplify the code.
This transmogrifies some of the things committed in
0ffb41440661631fa1d520c152be4cf8ebd4c46b "Add JUnit XML reports; refactor test
reporting", which did not fully match the code structuring ideas used in
osmo-gsm-tester. Also solve some problems present from the start of the code
base.
Though this is a bit of a code bomb, it would take a lot of time to separate
this into smaller bits: these changes are closely related and resulted
incrementally from testing error handling and logging details. I hope it's ok.
Things changed / problems fixed:
Allow only a single trial to be run per cmdline invocation: unbloat trial and
suite invocation in osmo-gsm-tester.py.
There is a SuiteDefinition, intended to be immutable, and a mutable SuiteRun.
SuiteDefinition had a list of tests, which was modified by the SuiteRun to
record test results. Instead, have only the test basenames in the
SuiteDefinition and create a new set of Test() instances for each SuiteRun, to
ensure that no state leaks between separate suite runs.
State leaking across runs can be seen in
http://jenkins.osmocom.org/jenkins/view/osmo-gsm-tester/job/osmo-gsm-tester_run/453/
where an earlier sms test for sysmo succeeds, but its state gets overwritten by
the later sms test for trx that fails. The end result is that both tests
failed, although the first run was successful.
Fix a problem with Origin: log.Origin allowed to be __enter__ed more than once,
skipping the second entry. The problem there is that we'd still __exit__ twice
or more, popping the Origin off the stack even though it should still remain.
We could count __enter__ recurrences, but instead, completely disallow entering
a second time.
A code path should have one 'with' statement per object, at pivotal points like
run_suites or run_tests. Individual utility functions should not do 'with' on a
central object. The structure needed is, in pseudo code:
try:
with trial:
try:
with suite_run:
try:
with test:
test_actions()
The 'with' needs to be inside the 'try', so that the exception can be handled
in __exit__ before it reaches the exception logging.
To clarify this, like test exceptions caught in Test.run(), also move suite
exception handling from Trial into SuiteRun.run_tests(). There are 'with self'
in Test.run() and SuiteRun.run_tests(), which are well placed, because these
are pivotal points in the main code path.
Log output: clearly separate logging of distinct suites and test scripts, by
adding more large_separator() calls at the start of each test. Place these
separator calls in more logical places. Add separator size and spacing args.
Log output: print tracebacks only once, for the test script where they happen.
Have less state that duplicates other state: drop SuiteRun.test_failed_ctr and
suite.test_skipped_ctr, instead add SuiteRun.count_test_results().
For test failure reporting, store the traceback text in a separate member var.
In the text report, apply above changes and unclutter to achieve a brief and
easy to read result overview: print less filler characters, drop the starting
times, drop the tracebacks. This can be found in the individual test logs.
Because the tracebacks are no longer in the text report, the suite_test.py can
just print the reports and expect that output instead of asserting individual
contents.
In the text report, print duration in precision of .1 seconds.
Add origin information and a traceback text to the junit XML result to give
more context when browsing the result XML. For 'AssertionError', add the source
line of where the assertion hit.
Drop the explicit Failure exception. We don't need one specific exception to
mark a failure, instead any arbitrary exception is treated as a failure. Use
the exception's class name as fail_type.
Though my original idea was to use raising exceptions as the only way to cause
a test failure, I'm keeping the set_fail() function as an alternative way,
because it allows test specific cleanup and may come in handy later. To have
both ways integrate seamlessly, shift some result setting into 'finally'
clauses and make sure higher levels (suite, trial) count the contained items'
stati.
Minor tweak: write the 'pass' and 'skip' reports in lower case so that the
'FAIL' stands out.
Minor tweak: pass the return code that the program exit should return further
outward, so that the exit(1) call does not cause a SystemExit exception to be
logged.
The aims of this patch are:
- Logs are readable so that it is clear which logging belongs to which test and
suite.
- The logging origins are correct (vs. parents gone missing as previously)
- A single test error does not cause following tests or suites to be skipped.
- An exception "above" Exception, i.e. SystemExit and the like, *does*
immediately abort all tests and suites, and the results for tests that were
not run are reported as "unknown" (rather than skipped on purpose):
- Raising a SystemExit aborts all.
- Hitting ctrl-c aborts all.
- The resulting summary in the log is brief and readable.
Change-Id: Ibf0846d457cab26f54c25e6906a8bb304724e2d8
2017-06-06 17:41:17 +00:00
|
|
|
for def_test_name in suite_def.test_basenames:
|
2017-05-06 14:04:37 +00:00
|
|
|
if test_name.startswith('='):
|
refactor: fix error handling; fix log.Origin; only one trial
A bit of refactoring to fix logging and error reporting, and simplify the code.
This transmogrifies some of the things committed in
0ffb41440661631fa1d520c152be4cf8ebd4c46b "Add JUnit XML reports; refactor test
reporting", which did not fully match the code structuring ideas used in
osmo-gsm-tester. Also solve some problems present from the start of the code
base.
Though this is a bit of a code bomb, it would take a lot of time to separate
this into smaller bits: these changes are closely related and resulted
incrementally from testing error handling and logging details. I hope it's ok.
Things changed / problems fixed:
Allow only a single trial to be run per cmdline invocation: unbloat trial and
suite invocation in osmo-gsm-tester.py.
There is a SuiteDefinition, intended to be immutable, and a mutable SuiteRun.
SuiteDefinition had a list of tests, which was modified by the SuiteRun to
record test results. Instead, have only the test basenames in the
SuiteDefinition and create a new set of Test() instances for each SuiteRun, to
ensure that no state leaks between separate suite runs.
State leaking across runs can be seen in
http://jenkins.osmocom.org/jenkins/view/osmo-gsm-tester/job/osmo-gsm-tester_run/453/
where an earlier sms test for sysmo succeeds, but its state gets overwritten by
the later sms test for trx that fails. The end result is that both tests
failed, although the first run was successful.
Fix a problem with Origin: log.Origin allowed to be __enter__ed more than once,
skipping the second entry. The problem there is that we'd still __exit__ twice
or more, popping the Origin off the stack even though it should still remain.
We could count __enter__ recurrences, but instead, completely disallow entering
a second time.
A code path should have one 'with' statement per object, at pivotal points like
run_suites or run_tests. Individual utility functions should not do 'with' on a
central object. The structure needed is, in pseudo code:
try:
with trial:
try:
with suite_run:
try:
with test:
test_actions()
The 'with' needs to be inside the 'try', so that the exception can be handled
in __exit__ before it reaches the exception logging.
To clarify this, like test exceptions caught in Test.run(), also move suite
exception handling from Trial into SuiteRun.run_tests(). There are 'with self'
in Test.run() and SuiteRun.run_tests(), which are well placed, because these
are pivotal points in the main code path.
Log output: clearly separate logging of distinct suites and test scripts, by
adding more large_separator() calls at the start of each test. Place these
separator calls in more logical places. Add separator size and spacing args.
Log output: print tracebacks only once, for the test script where they happen.
Have less state that duplicates other state: drop SuiteRun.test_failed_ctr and
suite.test_skipped_ctr, instead add SuiteRun.count_test_results().
For test failure reporting, store the traceback text in a separate member var.
In the text report, apply above changes and unclutter to achieve a brief and
easy to read result overview: print less filler characters, drop the starting
times, drop the tracebacks. This can be found in the individual test logs.
Because the tracebacks are no longer in the text report, the suite_test.py can
just print the reports and expect that output instead of asserting individual
contents.
In the text report, print duration in precision of .1 seconds.
Add origin information and a traceback text to the junit XML result to give
more context when browsing the result XML. For 'AssertionError', add the source
line of where the assertion hit.
Drop the explicit Failure exception. We don't need one specific exception to
mark a failure, instead any arbitrary exception is treated as a failure. Use
the exception's class name as fail_type.
Though my original idea was to use raising exceptions as the only way to cause
a test failure, I'm keeping the set_fail() function as an alternative way,
because it allows test specific cleanup and may come in handy later. To have
both ways integrate seamlessly, shift some result setting into 'finally'
clauses and make sure higher levels (suite, trial) count the contained items'
stati.
Minor tweak: write the 'pass' and 'skip' reports in lower case so that the
'FAIL' stands out.
Minor tweak: pass the return code that the program exit should return further
outward, so that the exit(1) call does not cause a SystemExit exception to be
logged.
The aims of this patch are:
- Logs are readable so that it is clear which logging belongs to which test and
suite.
- The logging origins are correct (vs. parents gone missing as previously)
- A single test error does not cause following tests or suites to be skipped.
- An exception "above" Exception, i.e. SystemExit and the like, *does*
immediately abort all tests and suites, and the results for tests that were
not run are reported as "unknown" (rather than skipped on purpose):
- Raising a SystemExit aborts all.
- Hitting ctrl-c aborts all.
- The resulting summary in the log is brief and readable.
Change-Id: Ibf0846d457cab26f54c25e6906a8bb304724e2d8
2017-06-06 17:41:17 +00:00
|
|
|
match = test_name[1:] == def_test_name
|
2017-05-06 14:04:37 +00:00
|
|
|
else:
|
refactor: fix error handling; fix log.Origin; only one trial
A bit of refactoring to fix logging and error reporting, and simplify the code.
This transmogrifies some of the things committed in
0ffb41440661631fa1d520c152be4cf8ebd4c46b "Add JUnit XML reports; refactor test
reporting", which did not fully match the code structuring ideas used in
osmo-gsm-tester. Also solve some problems present from the start of the code
base.
Though this is a bit of a code bomb, it would take a lot of time to separate
this into smaller bits: these changes are closely related and resulted
incrementally from testing error handling and logging details. I hope it's ok.
Things changed / problems fixed:
Allow only a single trial to be run per cmdline invocation: unbloat trial and
suite invocation in osmo-gsm-tester.py.
There is a SuiteDefinition, intended to be immutable, and a mutable SuiteRun.
SuiteDefinition had a list of tests, which was modified by the SuiteRun to
record test results. Instead, have only the test basenames in the
SuiteDefinition and create a new set of Test() instances for each SuiteRun, to
ensure that no state leaks between separate suite runs.
State leaking across runs can be seen in
http://jenkins.osmocom.org/jenkins/view/osmo-gsm-tester/job/osmo-gsm-tester_run/453/
where an earlier sms test for sysmo succeeds, but its state gets overwritten by
the later sms test for trx that fails. The end result is that both tests
failed, although the first run was successful.
Fix a problem with Origin: log.Origin allowed to be __enter__ed more than once,
skipping the second entry. The problem there is that we'd still __exit__ twice
or more, popping the Origin off the stack even though it should still remain.
We could count __enter__ recurrences, but instead, completely disallow entering
a second time.
A code path should have one 'with' statement per object, at pivotal points like
run_suites or run_tests. Individual utility functions should not do 'with' on a
central object. The structure needed is, in pseudo code:
try:
with trial:
try:
with suite_run:
try:
with test:
test_actions()
The 'with' needs to be inside the 'try', so that the exception can be handled
in __exit__ before it reaches the exception logging.
To clarify this, like test exceptions caught in Test.run(), also move suite
exception handling from Trial into SuiteRun.run_tests(). There are 'with self'
in Test.run() and SuiteRun.run_tests(), which are well placed, because these
are pivotal points in the main code path.
Log output: clearly separate logging of distinct suites and test scripts, by
adding more large_separator() calls at the start of each test. Place these
separator calls in more logical places. Add separator size and spacing args.
Log output: print tracebacks only once, for the test script where they happen.
Have less state that duplicates other state: drop SuiteRun.test_failed_ctr and
suite.test_skipped_ctr, instead add SuiteRun.count_test_results().
For test failure reporting, store the traceback text in a separate member var.
In the text report, apply above changes and unclutter to achieve a brief and
easy to read result overview: print less filler characters, drop the starting
times, drop the tracebacks. This can be found in the individual test logs.
Because the tracebacks are no longer in the text report, the suite_test.py can
just print the reports and expect that output instead of asserting individual
contents.
In the text report, print duration in precision of .1 seconds.
Add origin information and a traceback text to the junit XML result to give
more context when browsing the result XML. For 'AssertionError', add the source
line of where the assertion hit.
Drop the explicit Failure exception. We don't need one specific exception to
mark a failure, instead any arbitrary exception is treated as a failure. Use
the exception's class name as fail_type.
Though my original idea was to use raising exceptions as the only way to cause
a test failure, I'm keeping the set_fail() function as an alternative way,
because it allows test specific cleanup and may come in handy later. To have
both ways integrate seamlessly, shift some result setting into 'finally'
clauses and make sure higher levels (suite, trial) count the contained items'
stati.
Minor tweak: write the 'pass' and 'skip' reports in lower case so that the
'FAIL' stands out.
Minor tweak: pass the return code that the program exit should return further
outward, so that the exit(1) call does not cause a SystemExit exception to be
logged.
The aims of this patch are:
- Logs are readable so that it is clear which logging belongs to which test and
suite.
- The logging origins are correct (vs. parents gone missing as previously)
- A single test error does not cause following tests or suites to be skipped.
- An exception "above" Exception, i.e. SystemExit and the like, *does*
immediately abort all tests and suites, and the results for tests that were
not run are reported as "unknown" (rather than skipped on purpose):
- Raising a SystemExit aborts all.
- Hitting ctrl-c aborts all.
- The resulting summary in the log is brief and readable.
Change-Id: Ibf0846d457cab26f54c25e6906a8bb304724e2d8
2017-06-06 17:41:17 +00:00
|
|
|
match = test_name in def_test_name
|
2017-05-06 14:04:37 +00:00
|
|
|
if match:
|
2017-03-28 12:30:28 +00:00
|
|
|
found = True
|
refactor: fix error handling; fix log.Origin; only one trial
A bit of refactoring to fix logging and error reporting, and simplify the code.
This transmogrifies some of the things committed in
0ffb41440661631fa1d520c152be4cf8ebd4c46b "Add JUnit XML reports; refactor test
reporting", which did not fully match the code structuring ideas used in
osmo-gsm-tester. Also solve some problems present from the start of the code
base.
Though this is a bit of a code bomb, it would take a lot of time to separate
this into smaller bits: these changes are closely related and resulted
incrementally from testing error handling and logging details. I hope it's ok.
Things changed / problems fixed:
Allow only a single trial to be run per cmdline invocation: unbloat trial and
suite invocation in osmo-gsm-tester.py.
There is a SuiteDefinition, intended to be immutable, and a mutable SuiteRun.
SuiteDefinition had a list of tests, which was modified by the SuiteRun to
record test results. Instead, have only the test basenames in the
SuiteDefinition and create a new set of Test() instances for each SuiteRun, to
ensure that no state leaks between separate suite runs.
State leaking across runs can be seen in
http://jenkins.osmocom.org/jenkins/view/osmo-gsm-tester/job/osmo-gsm-tester_run/453/
where an earlier sms test for sysmo succeeds, but its state gets overwritten by
the later sms test for trx that fails. The end result is that both tests
failed, although the first run was successful.
Fix a problem with Origin: log.Origin allowed to be __enter__ed more than once,
skipping the second entry. The problem there is that we'd still __exit__ twice
or more, popping the Origin off the stack even though it should still remain.
We could count __enter__ recurrences, but instead, completely disallow entering
a second time.
A code path should have one 'with' statement per object, at pivotal points like
run_suites or run_tests. Individual utility functions should not do 'with' on a
central object. The structure needed is, in pseudo code:
try:
with trial:
try:
with suite_run:
try:
with test:
test_actions()
The 'with' needs to be inside the 'try', so that the exception can be handled
in __exit__ before it reaches the exception logging.
To clarify this, like test exceptions caught in Test.run(), also move suite
exception handling from Trial into SuiteRun.run_tests(). There are 'with self'
in Test.run() and SuiteRun.run_tests(), which are well placed, because these
are pivotal points in the main code path.
Log output: clearly separate logging of distinct suites and test scripts, by
adding more large_separator() calls at the start of each test. Place these
separator calls in more logical places. Add separator size and spacing args.
Log output: print tracebacks only once, for the test script where they happen.
Have less state that duplicates other state: drop SuiteRun.test_failed_ctr and
suite.test_skipped_ctr, instead add SuiteRun.count_test_results().
For test failure reporting, store the traceback text in a separate member var.
In the text report, apply above changes and unclutter to achieve a brief and
easy to read result overview: print less filler characters, drop the starting
times, drop the tracebacks. This can be found in the individual test logs.
Because the tracebacks are no longer in the text report, the suite_test.py can
just print the reports and expect that output instead of asserting individual
contents.
In the text report, print duration in precision of .1 seconds.
Add origin information and a traceback text to the junit XML result to give
more context when browsing the result XML. For 'AssertionError', add the source
line of where the assertion hit.
Drop the explicit Failure exception. We don't need one specific exception to
mark a failure, instead any arbitrary exception is treated as a failure. Use
the exception's class name as fail_type.
Though my original idea was to use raising exceptions as the only way to cause
a test failure, I'm keeping the set_fail() function as an alternative way,
because it allows test specific cleanup and may come in handy later. To have
both ways integrate seamlessly, shift some result setting into 'finally'
clauses and make sure higher levels (suite, trial) count the contained items'
stati.
Minor tweak: write the 'pass' and 'skip' reports in lower case so that the
'FAIL' stands out.
Minor tweak: pass the return code that the program exit should return further
outward, so that the exit(1) call does not cause a SystemExit exception to be
logged.
The aims of this patch are:
- Logs are readable so that it is clear which logging belongs to which test and
suite.
- The logging origins are correct (vs. parents gone missing as previously)
- A single test error does not cause following tests or suites to be skipped.
- An exception "above" Exception, i.e. SystemExit and the like, *does*
immediately abort all tests and suites, and the results for tests that were
not run are reported as "unknown" (rather than skipped on purpose):
- Raising a SystemExit aborts all.
- Hitting ctrl-c aborts all.
- The resulting summary in the log is brief and readable.
Change-Id: Ibf0846d457cab26f54c25e6906a8bb304724e2d8
2017-06-06 17:41:17 +00:00
|
|
|
test_names.append(def_test_name)
|
2017-03-28 12:30:28 +00:00
|
|
|
if not found:
|
|
|
|
raise RuntimeError('No test found for %r' % test_name)
|
|
|
|
if test_names:
|
refactor: fix error handling; fix log.Origin; only one trial
A bit of refactoring to fix logging and error reporting, and simplify the code.
This transmogrifies some of the things committed in
0ffb41440661631fa1d520c152be4cf8ebd4c46b "Add JUnit XML reports; refactor test
reporting", which did not fully match the code structuring ideas used in
osmo-gsm-tester. Also solve some problems present from the start of the code
base.
Though this is a bit of a code bomb, it would take a lot of time to separate
this into smaller bits: these changes are closely related and resulted
incrementally from testing error handling and logging details. I hope it's ok.
Things changed / problems fixed:
Allow only a single trial to be run per cmdline invocation: unbloat trial and
suite invocation in osmo-gsm-tester.py.
There is a SuiteDefinition, intended to be immutable, and a mutable SuiteRun.
SuiteDefinition had a list of tests, which was modified by the SuiteRun to
record test results. Instead, have only the test basenames in the
SuiteDefinition and create a new set of Test() instances for each SuiteRun, to
ensure that no state leaks between separate suite runs.
State leaking across runs can be seen in
http://jenkins.osmocom.org/jenkins/view/osmo-gsm-tester/job/osmo-gsm-tester_run/453/
where an earlier sms test for sysmo succeeds, but its state gets overwritten by
the later sms test for trx that fails. The end result is that both tests
failed, although the first run was successful.
Fix a problem with Origin: log.Origin allowed to be __enter__ed more than once,
skipping the second entry. The problem there is that we'd still __exit__ twice
or more, popping the Origin off the stack even though it should still remain.
We could count __enter__ recurrences, but instead, completely disallow entering
a second time.
A code path should have one 'with' statement per object, at pivotal points like
run_suites or run_tests. Individual utility functions should not do 'with' on a
central object. The structure needed is, in pseudo code:
try:
with trial:
try:
with suite_run:
try:
with test:
test_actions()
The 'with' needs to be inside the 'try', so that the exception can be handled
in __exit__ before it reaches the exception logging.
To clarify this, like test exceptions caught in Test.run(), also move suite
exception handling from Trial into SuiteRun.run_tests(). There are 'with self'
in Test.run() and SuiteRun.run_tests(), which are well placed, because these
are pivotal points in the main code path.
Log output: clearly separate logging of distinct suites and test scripts, by
adding more large_separator() calls at the start of each test. Place these
separator calls in more logical places. Add separator size and spacing args.
Log output: print tracebacks only once, for the test script where they happen.
Have less state that duplicates other state: drop SuiteRun.test_failed_ctr and
suite.test_skipped_ctr, instead add SuiteRun.count_test_results().
For test failure reporting, store the traceback text in a separate member var.
In the text report, apply above changes and unclutter to achieve a brief and
easy to read result overview: print less filler characters, drop the starting
times, drop the tracebacks. This can be found in the individual test logs.
Because the tracebacks are no longer in the text report, the suite_test.py can
just print the reports and expect that output instead of asserting individual
contents.
In the text report, print duration in precision of .1 seconds.
Add origin information and a traceback text to the junit XML result to give
more context when browsing the result XML. For 'AssertionError', add the source
line of where the assertion hit.
Drop the explicit Failure exception. We don't need one specific exception to
mark a failure, instead any arbitrary exception is treated as a failure. Use
the exception's class name as fail_type.
Though my original idea was to use raising exceptions as the only way to cause
a test failure, I'm keeping the set_fail() function as an alternative way,
because it allows test specific cleanup and may come in handy later. To have
both ways integrate seamlessly, shift some result setting into 'finally'
clauses and make sure higher levels (suite, trial) count the contained items'
stati.
Minor tweak: write the 'pass' and 'skip' reports in lower case so that the
'FAIL' stands out.
Minor tweak: pass the return code that the program exit should return further
outward, so that the exit(1) call does not cause a SystemExit exception to be
logged.
The aims of this patch are:
- Logs are readable so that it is clear which logging belongs to which test and
suite.
- The logging origins are correct (vs. parents gone missing as previously)
- A single test error does not cause following tests or suites to be skipped.
- An exception "above" Exception, i.e. SystemExit and the like, *does*
immediately abort all tests and suites, and the results for tests that were
not run are reported as "unknown" (rather than skipped on purpose):
- Raising a SystemExit aborts all.
- Hitting ctrl-c aborts all.
- The resulting summary in the log is brief and readable.
Change-Id: Ibf0846d457cab26f54c25e6906a8bb304724e2d8
2017-06-06 17:41:17 +00:00
|
|
|
test_names = sorted(set(test_names))
|
2017-03-28 12:30:28 +00:00
|
|
|
print(repr(test_names))
|
|
|
|
|
refactor: fix error handling; fix log.Origin; only one trial
A bit of refactoring to fix logging and error reporting, and simplify the code.
This transmogrifies some of the things committed in
0ffb41440661631fa1d520c152be4cf8ebd4c46b "Add JUnit XML reports; refactor test
reporting", which did not fully match the code structuring ideas used in
osmo-gsm-tester. Also solve some problems present from the start of the code
base.
Though this is a bit of a code bomb, it would take a lot of time to separate
this into smaller bits: these changes are closely related and resulted
incrementally from testing error handling and logging details. I hope it's ok.
Things changed / problems fixed:
Allow only a single trial to be run per cmdline invocation: unbloat trial and
suite invocation in osmo-gsm-tester.py.
There is a SuiteDefinition, intended to be immutable, and a mutable SuiteRun.
SuiteDefinition had a list of tests, which was modified by the SuiteRun to
record test results. Instead, have only the test basenames in the
SuiteDefinition and create a new set of Test() instances for each SuiteRun, to
ensure that no state leaks between separate suite runs.
State leaking across runs can be seen in
http://jenkins.osmocom.org/jenkins/view/osmo-gsm-tester/job/osmo-gsm-tester_run/453/
where an earlier sms test for sysmo succeeds, but its state gets overwritten by
the later sms test for trx that fails. The end result is that both tests
failed, although the first run was successful.
Fix a problem with Origin: log.Origin allowed to be __enter__ed more than once,
skipping the second entry. The problem there is that we'd still __exit__ twice
or more, popping the Origin off the stack even though it should still remain.
We could count __enter__ recurrences, but instead, completely disallow entering
a second time.
A code path should have one 'with' statement per object, at pivotal points like
run_suites or run_tests. Individual utility functions should not do 'with' on a
central object. The structure needed is, in pseudo code:
try:
with trial:
try:
with suite_run:
try:
with test:
test_actions()
The 'with' needs to be inside the 'try', so that the exception can be handled
in __exit__ before it reaches the exception logging.
To clarify this, like test exceptions caught in Test.run(), also move suite
exception handling from Trial into SuiteRun.run_tests(). There are 'with self'
in Test.run() and SuiteRun.run_tests(), which are well placed, because these
are pivotal points in the main code path.
Log output: clearly separate logging of distinct suites and test scripts, by
adding more large_separator() calls at the start of each test. Place these
separator calls in more logical places. Add separator size and spacing args.
Log output: print tracebacks only once, for the test script where they happen.
Have less state that duplicates other state: drop SuiteRun.test_failed_ctr and
suite.test_skipped_ctr, instead add SuiteRun.count_test_results().
For test failure reporting, store the traceback text in a separate member var.
In the text report, apply above changes and unclutter to achieve a brief and
easy to read result overview: print less filler characters, drop the starting
times, drop the tracebacks. This can be found in the individual test logs.
Because the tracebacks are no longer in the text report, the suite_test.py can
just print the reports and expect that output instead of asserting individual
contents.
In the text report, print duration in precision of .1 seconds.
Add origin information and a traceback text to the junit XML result to give
more context when browsing the result XML. For 'AssertionError', add the source
line of where the assertion hit.
Drop the explicit Failure exception. We don't need one specific exception to
mark a failure, instead any arbitrary exception is treated as a failure. Use
the exception's class name as fail_type.
Though my original idea was to use raising exceptions as the only way to cause
a test failure, I'm keeping the set_fail() function as an alternative way,
because it allows test specific cleanup and may come in handy later. To have
both ways integrate seamlessly, shift some result setting into 'finally'
clauses and make sure higher levels (suite, trial) count the contained items'
stati.
Minor tweak: write the 'pass' and 'skip' reports in lower case so that the
'FAIL' stands out.
Minor tweak: pass the return code that the program exit should return further
outward, so that the exit(1) call does not cause a SystemExit exception to be
logged.
The aims of this patch are:
- Logs are readable so that it is clear which logging belongs to which test and
suite.
- The logging origins are correct (vs. parents gone missing as previously)
- A single test error does not cause following tests or suites to be skipped.
- An exception "above" Exception, i.e. SystemExit and the like, *does*
immediately abort all tests and suites, and the results for tests that were
not run are reported as "unknown" (rather than skipped on purpose):
- Raising a SystemExit aborts all.
- Hitting ctrl-c aborts all.
- The resulting summary in the log is brief and readable.
Change-Id: Ibf0846d457cab26f54c25e6906a8bb304724e2d8
2017-06-06 17:41:17 +00:00
|
|
|
with trial.Trial(args.trial_package) as current_trial:
|
|
|
|
current_trial.verify()
|
|
|
|
for suite_scenario_str, suite_def, scenarios in suite_scenarios:
|
|
|
|
current_trial.add_suite_run(suite_scenario_str, suite_def, scenarios)
|
|
|
|
current_trial.run_suites(test_names)
|
|
|
|
|
|
|
|
if current_trial.status != trial.Trial.PASS:
|
|
|
|
return 1
|
|
|
|
return 0
|
2017-03-28 10:16:58 +00:00
|
|
|
|
2017-05-14 01:00:21 +00:00
|
|
|
if __name__ == '__main__':
|
refactor: fix error handling; fix log.Origin; only one trial
A bit of refactoring to fix logging and error reporting, and simplify the code.
This transmogrifies some of the things committed in
0ffb41440661631fa1d520c152be4cf8ebd4c46b "Add JUnit XML reports; refactor test
reporting", which did not fully match the code structuring ideas used in
osmo-gsm-tester. Also solve some problems present from the start of the code
base.
Though this is a bit of a code bomb, it would take a lot of time to separate
this into smaller bits: these changes are closely related and resulted
incrementally from testing error handling and logging details. I hope it's ok.
Things changed / problems fixed:
Allow only a single trial to be run per cmdline invocation: unbloat trial and
suite invocation in osmo-gsm-tester.py.
There is a SuiteDefinition, intended to be immutable, and a mutable SuiteRun.
SuiteDefinition had a list of tests, which was modified by the SuiteRun to
record test results. Instead, have only the test basenames in the
SuiteDefinition and create a new set of Test() instances for each SuiteRun, to
ensure that no state leaks between separate suite runs.
State leaking across runs can be seen in
http://jenkins.osmocom.org/jenkins/view/osmo-gsm-tester/job/osmo-gsm-tester_run/453/
where an earlier sms test for sysmo succeeds, but its state gets overwritten by
the later sms test for trx that fails. The end result is that both tests
failed, although the first run was successful.
Fix a problem with Origin: log.Origin allowed to be __enter__ed more than once,
skipping the second entry. The problem there is that we'd still __exit__ twice
or more, popping the Origin off the stack even though it should still remain.
We could count __enter__ recurrences, but instead, completely disallow entering
a second time.
A code path should have one 'with' statement per object, at pivotal points like
run_suites or run_tests. Individual utility functions should not do 'with' on a
central object. The structure needed is, in pseudo code:
try:
with trial:
try:
with suite_run:
try:
with test:
test_actions()
The 'with' needs to be inside the 'try', so that the exception can be handled
in __exit__ before it reaches the exception logging.
To clarify this, like test exceptions caught in Test.run(), also move suite
exception handling from Trial into SuiteRun.run_tests(). There are 'with self'
in Test.run() and SuiteRun.run_tests(), which are well placed, because these
are pivotal points in the main code path.
Log output: clearly separate logging of distinct suites and test scripts, by
adding more large_separator() calls at the start of each test. Place these
separator calls in more logical places. Add separator size and spacing args.
Log output: print tracebacks only once, for the test script where they happen.
Have less state that duplicates other state: drop SuiteRun.test_failed_ctr and
suite.test_skipped_ctr, instead add SuiteRun.count_test_results().
For test failure reporting, store the traceback text in a separate member var.
In the text report, apply above changes and unclutter to achieve a brief and
easy to read result overview: print less filler characters, drop the starting
times, drop the tracebacks. This can be found in the individual test logs.
Because the tracebacks are no longer in the text report, the suite_test.py can
just print the reports and expect that output instead of asserting individual
contents.
In the text report, print duration in precision of .1 seconds.
Add origin information and a traceback text to the junit XML result to give
more context when browsing the result XML. For 'AssertionError', add the source
line of where the assertion hit.
Drop the explicit Failure exception. We don't need one specific exception to
mark a failure, instead any arbitrary exception is treated as a failure. Use
the exception's class name as fail_type.
Though my original idea was to use raising exceptions as the only way to cause
a test failure, I'm keeping the set_fail() function as an alternative way,
because it allows test specific cleanup and may come in handy later. To have
both ways integrate seamlessly, shift some result setting into 'finally'
clauses and make sure higher levels (suite, trial) count the contained items'
stati.
Minor tweak: write the 'pass' and 'skip' reports in lower case so that the
'FAIL' stands out.
Minor tweak: pass the return code that the program exit should return further
outward, so that the exit(1) call does not cause a SystemExit exception to be
logged.
The aims of this patch are:
- Logs are readable so that it is clear which logging belongs to which test and
suite.
- The logging origins are correct (vs. parents gone missing as previously)
- A single test error does not cause following tests or suites to be skipped.
- An exception "above" Exception, i.e. SystemExit and the like, *does*
immediately abort all tests and suites, and the results for tests that were
not run are reported as "unknown" (rather than skipped on purpose):
- Raising a SystemExit aborts all.
- Hitting ctrl-c aborts all.
- The resulting summary in the log is brief and readable.
Change-Id: Ibf0846d457cab26f54c25e6906a8bb304724e2d8
2017-06-06 17:41:17 +00:00
|
|
|
rc = 2
|
2017-05-14 01:00:21 +00:00
|
|
|
try:
|
refactor: fix error handling; fix log.Origin; only one trial
A bit of refactoring to fix logging and error reporting, and simplify the code.
This transmogrifies some of the things committed in
0ffb41440661631fa1d520c152be4cf8ebd4c46b "Add JUnit XML reports; refactor test
reporting", which did not fully match the code structuring ideas used in
osmo-gsm-tester. Also solve some problems present from the start of the code
base.
Though this is a bit of a code bomb, it would take a lot of time to separate
this into smaller bits: these changes are closely related and resulted
incrementally from testing error handling and logging details. I hope it's ok.
Things changed / problems fixed:
Allow only a single trial to be run per cmdline invocation: unbloat trial and
suite invocation in osmo-gsm-tester.py.
There is a SuiteDefinition, intended to be immutable, and a mutable SuiteRun.
SuiteDefinition had a list of tests, which was modified by the SuiteRun to
record test results. Instead, have only the test basenames in the
SuiteDefinition and create a new set of Test() instances for each SuiteRun, to
ensure that no state leaks between separate suite runs.
State leaking across runs can be seen in
http://jenkins.osmocom.org/jenkins/view/osmo-gsm-tester/job/osmo-gsm-tester_run/453/
where an earlier sms test for sysmo succeeds, but its state gets overwritten by
the later sms test for trx that fails. The end result is that both tests
failed, although the first run was successful.
Fix a problem with Origin: log.Origin allowed to be __enter__ed more than once,
skipping the second entry. The problem there is that we'd still __exit__ twice
or more, popping the Origin off the stack even though it should still remain.
We could count __enter__ recurrences, but instead, completely disallow entering
a second time.
A code path should have one 'with' statement per object, at pivotal points like
run_suites or run_tests. Individual utility functions should not do 'with' on a
central object. The structure needed is, in pseudo code:
try:
with trial:
try:
with suite_run:
try:
with test:
test_actions()
The 'with' needs to be inside the 'try', so that the exception can be handled
in __exit__ before it reaches the exception logging.
To clarify this, like test exceptions caught in Test.run(), also move suite
exception handling from Trial into SuiteRun.run_tests(). There are 'with self'
in Test.run() and SuiteRun.run_tests(), which are well placed, because these
are pivotal points in the main code path.
Log output: clearly separate logging of distinct suites and test scripts, by
adding more large_separator() calls at the start of each test. Place these
separator calls in more logical places. Add separator size and spacing args.
Log output: print tracebacks only once, for the test script where they happen.
Have less state that duplicates other state: drop SuiteRun.test_failed_ctr and
suite.test_skipped_ctr, instead add SuiteRun.count_test_results().
For test failure reporting, store the traceback text in a separate member var.
In the text report, apply above changes and unclutter to achieve a brief and
easy to read result overview: print less filler characters, drop the starting
times, drop the tracebacks. This can be found in the individual test logs.
Because the tracebacks are no longer in the text report, the suite_test.py can
just print the reports and expect that output instead of asserting individual
contents.
In the text report, print duration in precision of .1 seconds.
Add origin information and a traceback text to the junit XML result to give
more context when browsing the result XML. For 'AssertionError', add the source
line of where the assertion hit.
Drop the explicit Failure exception. We don't need one specific exception to
mark a failure, instead any arbitrary exception is treated as a failure. Use
the exception's class name as fail_type.
Though my original idea was to use raising exceptions as the only way to cause
a test failure, I'm keeping the set_fail() function as an alternative way,
because it allows test specific cleanup and may come in handy later. To have
both ways integrate seamlessly, shift some result setting into 'finally'
clauses and make sure higher levels (suite, trial) count the contained items'
stati.
Minor tweak: write the 'pass' and 'skip' reports in lower case so that the
'FAIL' stands out.
Minor tweak: pass the return code that the program exit should return further
outward, so that the exit(1) call does not cause a SystemExit exception to be
logged.
The aims of this patch are:
- Logs are readable so that it is clear which logging belongs to which test and
suite.
- The logging origins are correct (vs. parents gone missing as previously)
- A single test error does not cause following tests or suites to be skipped.
- An exception "above" Exception, i.e. SystemExit and the like, *does*
immediately abort all tests and suites, and the results for tests that were
not run are reported as "unknown" (rather than skipped on purpose):
- Raising a SystemExit aborts all.
- Hitting ctrl-c aborts all.
- The resulting summary in the log is brief and readable.
Change-Id: Ibf0846d457cab26f54c25e6906a8bb304724e2d8
2017-06-06 17:41:17 +00:00
|
|
|
rc = main()
|
2017-05-14 01:00:21 +00:00
|
|
|
except:
|
|
|
|
# Tell the log to show the exception, then terminate the program with the exception anyway.
|
|
|
|
# Since exceptions within test runs should be caught and evaluated, this is basically about
|
|
|
|
# exceptions during command line parsing and such, so it's appropriate to abort immediately.
|
|
|
|
log.log_exn()
|
|
|
|
raise
|
refactor: fix error handling; fix log.Origin; only one trial
A bit of refactoring to fix logging and error reporting, and simplify the code.
This transmogrifies some of the things committed in
0ffb41440661631fa1d520c152be4cf8ebd4c46b "Add JUnit XML reports; refactor test
reporting", which did not fully match the code structuring ideas used in
osmo-gsm-tester. Also solve some problems present from the start of the code
base.
Though this is a bit of a code bomb, it would take a lot of time to separate
this into smaller bits: these changes are closely related and resulted
incrementally from testing error handling and logging details. I hope it's ok.
Things changed / problems fixed:
Allow only a single trial to be run per cmdline invocation: unbloat trial and
suite invocation in osmo-gsm-tester.py.
There is a SuiteDefinition, intended to be immutable, and a mutable SuiteRun.
SuiteDefinition had a list of tests, which was modified by the SuiteRun to
record test results. Instead, have only the test basenames in the
SuiteDefinition and create a new set of Test() instances for each SuiteRun, to
ensure that no state leaks between separate suite runs.
State leaking across runs can be seen in
http://jenkins.osmocom.org/jenkins/view/osmo-gsm-tester/job/osmo-gsm-tester_run/453/
where an earlier sms test for sysmo succeeds, but its state gets overwritten by
the later sms test for trx that fails. The end result is that both tests
failed, although the first run was successful.
Fix a problem with Origin: log.Origin allowed to be __enter__ed more than once,
skipping the second entry. The problem there is that we'd still __exit__ twice
or more, popping the Origin off the stack even though it should still remain.
We could count __enter__ recurrences, but instead, completely disallow entering
a second time.
A code path should have one 'with' statement per object, at pivotal points like
run_suites or run_tests. Individual utility functions should not do 'with' on a
central object. The structure needed is, in pseudo code:
try:
with trial:
try:
with suite_run:
try:
with test:
test_actions()
The 'with' needs to be inside the 'try', so that the exception can be handled
in __exit__ before it reaches the exception logging.
To clarify this, like test exceptions caught in Test.run(), also move suite
exception handling from Trial into SuiteRun.run_tests(). There are 'with self'
in Test.run() and SuiteRun.run_tests(), which are well placed, because these
are pivotal points in the main code path.
Log output: clearly separate logging of distinct suites and test scripts, by
adding more large_separator() calls at the start of each test. Place these
separator calls in more logical places. Add separator size and spacing args.
Log output: print tracebacks only once, for the test script where they happen.
Have less state that duplicates other state: drop SuiteRun.test_failed_ctr and
suite.test_skipped_ctr, instead add SuiteRun.count_test_results().
For test failure reporting, store the traceback text in a separate member var.
In the text report, apply above changes and unclutter to achieve a brief and
easy to read result overview: print less filler characters, drop the starting
times, drop the tracebacks. This can be found in the individual test logs.
Because the tracebacks are no longer in the text report, the suite_test.py can
just print the reports and expect that output instead of asserting individual
contents.
In the text report, print duration in precision of .1 seconds.
Add origin information and a traceback text to the junit XML result to give
more context when browsing the result XML. For 'AssertionError', add the source
line of where the assertion hit.
Drop the explicit Failure exception. We don't need one specific exception to
mark a failure, instead any arbitrary exception is treated as a failure. Use
the exception's class name as fail_type.
Though my original idea was to use raising exceptions as the only way to cause
a test failure, I'm keeping the set_fail() function as an alternative way,
because it allows test specific cleanup and may come in handy later. To have
both ways integrate seamlessly, shift some result setting into 'finally'
clauses and make sure higher levels (suite, trial) count the contained items'
stati.
Minor tweak: write the 'pass' and 'skip' reports in lower case so that the
'FAIL' stands out.
Minor tweak: pass the return code that the program exit should return further
outward, so that the exit(1) call does not cause a SystemExit exception to be
logged.
The aims of this patch are:
- Logs are readable so that it is clear which logging belongs to which test and
suite.
- The logging origins are correct (vs. parents gone missing as previously)
- A single test error does not cause following tests or suites to be skipped.
- An exception "above" Exception, i.e. SystemExit and the like, *does*
immediately abort all tests and suites, and the results for tests that were
not run are reported as "unknown" (rather than skipped on purpose):
- Raising a SystemExit aborts all.
- Hitting ctrl-c aborts all.
- The resulting summary in the log is brief and readable.
Change-Id: Ibf0846d457cab26f54c25e6906a8bb304724e2d8
2017-06-06 17:41:17 +00:00
|
|
|
exit(rc)
|
2017-05-14 01:00:21 +00:00
|
|
|
|
2017-03-28 10:16:58 +00:00
|
|
|
# vim: expandtab tabstop=4 shiftwidth=4
|