[[gb-sgsn-pool]]
|
|
== Gb interface in SGSN Pooling
|
|
|
|
SGSN Pooling is a modern optional extension of the 3GPP GERAN
|
|
architecture. It is officially referred-to as _Intra Domain Connection
|
|
of RAN Nodes to Multiple CN Nodes_. It requires The use of IP-SNS and
|
|
does not support legacy or non-standard Gb variants.
|
|
|
|
Without this optional feature, a given PCU/BSS always connects to one
|
|
SGSN via a Gb interface. All traffic is handled through that one
|
|
interface.
|
|
|
|
While the NS-level load sharing function and the _weights_ of the IP-SNS
|
|
allow for load distribution between different user plane entities, there
|
|
was demand for additional scalability and fail-over capabilities leading
|
|
to the SGSN pooling feature.
|
|
|
|
The major changes introduced to the Gb interface by SGSN pooling are as
|
|
follows:
|
|
|
|
* There is a separate NSE in the BSS for each of the SGSNs in the pool,
|
|
creating a 1:1 relationship between BSS-NSE and SGSN.
|
|
* Each of those per-SGSN NSEs has it's own NS-VCGs and NS-VCs, unrelated
|
|
to those of the other NSEs
|
|
* Each of those per-SGSN NSEs has it's own Signaling BVC
|
|
* Each Cell in the BSS has one PTP BVC _per SGSN in the pool_
|
|
|
|
This relationship is illustrated in <<fig-gb-pool>> below.
|
|
|
|
[[fig-gb-pool]]
|
|
.Gb interface concepts when SGSN pooling feature is used (from 3GPP TS 48.016)
|
|
image::./common/images/gb-concepts-pool.pdf[]
|
|
|
|
Looking strictly at the Gb interface, this means that there is a completely
|
|
separate Gb interface between each BSS and each pool member SGSN. All of the
|
|
procedures explained in <<gb-ip-sns>> hence occur N number of times to N number
|
|
of SGSN pool members.
|
|
|
|
=== Status of SGSN Pool support in Osmocom
|
|
|
|
==== osmo-pcu
|
|
|
|
There is currently no direct support for SGSN pooling in `osmo-pcu`
|
|
itself. However, as of December 2020, `osmo-gbproxy` is being extended
|
|
with SGSN pooling support.
|
|
|
|
This means that SGSN pooling can be added to any `osmo-pcu` based
|
|
deployment by introducing `osmo-gbproxy` between `osmo-pcu` and the SGSN.
|
|
|
|
The use of `osmo-gbproxy` also has the added benefit that all Gb
|
|
interfaces from various PCUs are aggregated into one Gb interface
|
|
towards (each) SGSN. Most deployments are used to such a _one interface
|
|
per BSS_ approach as they are used to the BSC-colocated PCU architecture
|
|
and not to the BTS-colocated PCU architecture as implemented in Osmocom.
|
|
|
|
==== osmo-gbproxy
|
|
|
|
FIXME
|
|
|
|
==== osmo-sgsn
|
|
|
|
FIXME
|