sysmo: Fix "nominal power" / BS power display in VTY
The function get_p_max_out_mdBm() returns a value in 1/1000th of dBm, "milli-dBm", while trx->nominal_power is only whole dBm. We were missing the required divider of 1000 ever since Change-Id Ieff75d5becaa80a2097b6e744c75c2d16259c9a4 was merged in February 2017. The good news is that this really only affected the VTY output and not any actual operational aspect of the system. Change-Id: If92d0b15c48dafc63776b82c7ff5f3c2b3505f68 Closes: SYS#4570
This commit is contained in:
parent
57f9a279e0
commit
d7be09caf8
|
@ -1883,7 +1883,7 @@ int bts_model_phy_link_open(struct phy_link *plink)
|
|||
LOGP(DL1C, LOGL_NOTICE, "Cannot determine nominal "
|
||||
"transmit power. Assuming 23dBm.\n");
|
||||
}
|
||||
bts->c0->nominal_power = rc;
|
||||
bts->c0->nominal_power = rc / 1000;
|
||||
}
|
||||
|
||||
hdl = pinst->u.sysmobts.hdl;
|
||||
|
|
Loading…