add a small document describing the use of the control interface
This commit is contained in:
parent
be18984959
commit
c0a3030277
|
@ -0,0 +1,57 @@
|
||||||
|
The osmo-bts control interface is currently supporting the following operations:
|
||||||
|
|
||||||
|
h2. generic
|
||||||
|
|
||||||
|
h3. trx.0.thermal-attenuation
|
||||||
|
|
||||||
|
The idea of this paramter is to attenuate the system output power as part of
|
||||||
|
thermal management. In some cases the PA might be passing a critical level,
|
||||||
|
so an external control process can use this attribute to reduce the system
|
||||||
|
output power.
|
||||||
|
|
||||||
|
<pre>
|
||||||
|
bsc_control.py -d localhost -p 4238 -s trx.0.thermal-attenuation 3
|
||||||
|
Got message: SET_REPLY 1 trx.0.thermal-attenuation 3
|
||||||
|
</pre>
|
||||||
|
|
||||||
|
<pre>
|
||||||
|
bsc_control.py -d localhost -p 4238 -g trx.0.thermal-attenuation
|
||||||
|
Got message: GET_REPLY 1 trx.0.thermal-attenuation 3
|
||||||
|
</pre>
|
||||||
|
|
||||||
|
|
||||||
|
h2. sysmobts specific
|
||||||
|
|
||||||
|
h3. trx.0.clock-info
|
||||||
|
|
||||||
|
obtain information on the current clock status:
|
||||||
|
|
||||||
|
<pre>
|
||||||
|
bsc_control.py -d localhost -p 4238 -g trx.0.clock-info
|
||||||
|
Got message: GET_REPLY 1 trx.0.clock-info -100,ocxo,0,0,gps
|
||||||
|
</pre>
|
||||||
|
|
||||||
|
which is to be interpreted as:
|
||||||
|
* current clock correction value is -100 ppb
|
||||||
|
* current clock source is OCXO
|
||||||
|
* deviation between clock source and calibration source is 0 ppb
|
||||||
|
* resolution of clock error measurement is 0 ppt (0 means no result yet)
|
||||||
|
* current calibration source is GPS
|
||||||
|
|
||||||
|
When this attribute is set, any value passed on is discarded, but the clock
|
||||||
|
calibration process is re-started.
|
||||||
|
|
||||||
|
|
||||||
|
h3. trx.0.clock-correction
|
||||||
|
|
||||||
|
This attribute can get and set the current clock correction value:
|
||||||
|
|
||||||
|
<pre>
|
||||||
|
bsc_control.py -d localhost -p 4238 -g trx.0.clock-correction
|
||||||
|
Got message: GET_REPLY 1 trx.0.clock-correction -100
|
||||||
|
</pre>
|
||||||
|
|
||||||
|
<pre>
|
||||||
|
bsc_control.py -d localhost -p 4238 -s trx.0.clock-correction -- -99
|
||||||
|
Got message: SET_REPLY 1 trx.0.clock-correction success
|
||||||
|
</pre>
|