RSL: Fix logic about fixed/dynamic MS power control in MS POWER COMMAND

The spec is quite clear: If the MS Power Parameters IE is present, then
the BTS shall perform autonomous MS power control.  If it's absent,
then the MS power shall be fied.  Let's adjust our code accordingly.

Change-Id: Ie43a1fc9cc658677c8c945ae82d03b7bffbe52d5
Related: OS#1622
This commit is contained in:
Harald Welte 2019-05-23 20:00:48 +02:00
parent 29aee05f75
commit bf5d8eed11
1 changed files with 21 additions and 6 deletions

View File

@ -1554,19 +1554,34 @@ static int rsl_rx_mode_modif(struct msgb *msg)
/* 8.4.15 MS POWER CONTROL */
static int rsl_rx_ms_pwr_ctrl(struct msgb *msg)
{
struct abis_rsl_dchan_hdr *dch = msgb_l2(msg);
struct gsm_lchan *lchan = msg->lchan;
struct tlv_parsed tp;
uint8_t pwr;
rsl_tlv_parse(&tp, msgb_l3(msg), msgb_l3len(msg));
if (TLVP_PRES_LEN(&tp, RSL_IE_MS_POWER, 1)) {
uint8_t pwr = *TLVP_VAL(&tp, RSL_IE_MS_POWER) & 0x1F;
lchan->ms_power_ctrl.fixed = 1;
lchan->ms_power_ctrl.current = pwr;
LOGPLCHAN(lchan, DRSL, LOGL_NOTICE, "forcing power to %d\n", lchan->ms_power_ctrl.current);
bts_model_adjst_ms_pwr(lchan);
/* 9.3.13 MS Power (M) */
if (!TLVP_PRES_LEN(&tp, RSL_IE_MS_POWER, 1))
return rsl_tx_error_report(msg->trx, RSL_ERR_MAND_IE_ERROR, &dch->chan_nr, NULL, msg);
pwr = *TLVP_VAL(&tp, RSL_IE_MS_POWER) & 0x1F;
lchan->ms_power_ctrl.current = pwr;
LOGPLCHAN(lchan, DRSL, LOGL_NOTICE, "forcing power to %d\n", lchan->ms_power_ctrl.current);
/* 9.3.31 MS Power Parameters (O) */
if (TLVP_PRESENT(&tp, RSL_IE_MS_POWER_PARAM))
lchan->ms_power_ctrl.fixed = 0;
else {
/* Spec explicitly states BTS should only perform
* autonomous MS power control loop in BTS if 'MS Power
* Parameters' IE is present! */
lchan->ms_power_ctrl.fixed = 1;
}
bts_model_adjst_ms_pwr(lchan);
return 0;
}