Presence of these lines in the config file does not necessarily mean
that the BTS will not perform measurement pre-processing. It actually
means that the BSC would not include the optional IEs related to the
measurement pre-processing, so the BTS may still apply its default
averaging algorythm with default parameters.
In order to avoid potential confusion, let's avoid printing them.
Change-Id: I585b5bf4fde93d66e47666e0fa9903f21a268b51
Related: SYS#4918
Before the recent changes, the MS Power Parameters IE would always
be included empty in RSL CHANnel ACTIVation messages iff the BTS
type is 'osmo-bts'. Then this behavior was changed, so the user
would need to enable dynamic power control explicitly.
This is a regression, let's revert it back to the old behaviour.
Change-Id: Idb453fc894584ccf4f5f8b45a24421db958e9478
Related: SYS#4918
According to 3GPP TS 45.008, section A.3.2.1:
c) Comparison of RXQUAL_XX with L_RXQUAL_XX_P (XX = DL or UL):
Increase XX_TXPWR if at least P3 averaged values out of N3
averaged values are greater (worse quality) than L_RXQUAL_XX_P.
d) Comparison of RXQUAL_XX with U_RXQUAL_XX_P (XX = DL or UL):
Decrease XX_TXPWR if at least P4 averaged values out of N4
averaged values are lower (better quality) than U_RXQUAL_XX_P.
Given that RxQual is a value in range 0 .. 7, where 0 is the best
and 7 is the worst: L_RXQUAL_XX_P must define the worst quality,
while U_RXQUAL_XX_P must define the best quality value.
Change-Id: I0f37b23ed360782f3c1f4275234c4e18a17aa89b
Related: SYS#4918