The MNCC Unix Domain Socket encoding uses an int here, which is
a bit odd, given that it's an ASCII / IA5 char value on the actual
GSM L3. Let's convert from/to something useful.
Change-Id: Id17ac502ca33f4962214a3d5938d0dc29ca6ec1b
- Add tests to check the behaviour on wildcarded DLCX and MDCX,
both commands not supported by the MGW and should fail.
Change-Id: I140c6d9e337cd16d6147bb582a9474cf76b5170b
The testcase TC_crcx_sdp does not clean up the connection it
created. This can cause subsequent tests to fail.
- Use f_dlcx_ok() to clean up the connection once the test
is done.
Change-Id: I4e0f5ce218fadc5debe0bbf548b69919584ab66c
The wildcarded CRCX is not tested yet.
- Add a test function that executes a single wildcarded CRCX
request
- Add a test function that exchausts all MGW resources using
wildcarded CRCX requests
Change-Id: I70cf486dc21aef19e4199289f5a5509f6927713e
The testcase for osmo-mgw hardcodes the mgw domain and also lacks
an endpoint identifier, which was deprecated recently.
- replace the hardcoded occurrences of the mgw domain name with
a constant
- add a constant for the rtpbridge endpoint identifier
- add a testcase that still uses the old method without prefix
on the endpoint identifier.
Change-Id: If4455c4cb521270b2fe24881ade9b578a5132205
When we page an unknown/unsupported CellIdentifier format, OsmoBSC
decides to page on all BTSs to be safe. This way we have a chance of
making communication happen, rather than breaking it.
Change-Id: Ibd0ba986d9e18758b519e852c36f4dbbb6b367ea
We now test all of the cell identification types specified in BSSMAP,
and also lists with a length != 1 entry.
Change-Id: I261f948d6054d0c90078c1dd0b2785a967b0a49b
We have to wait for sime time until some RSL paging command would have
arrived, rather than continuing too quickly.
Change-Id: I63827aa3c42f77648ecad401b3cc4bae927b3b94
It seems due to the current network configuration, pdp v4 ctx can talk
each other while pdp v6 ctx cannot.
Change-Id: I67c04b056cc5c092d357abbb084b7665f59eaf3a
New dependency is required: titan.ProtocolModules.ICMP
It tests that ICMP echo packets can be sent successfully (reply is
received or otherwise dest unreachable if routing is not set up
correctly during the test). It also tests some cases in which osmo-ggsn
is required to drop the packets (eg. unknown src ip unrelated to pdp
ctx). It also checks that IPv6 packets are dropped in IPv4 pdp ctx and
viceversa It also checks that IPv6 packets are dropped in IPv4 pdp ctx
and vice versa.
Change-Id: Ib9c6043a6cd3b6622782ec7e7fcd2815101755ba
MGCP permits for the CallAgent to send a wildcarded endpoint name,
at which point the MGW itself must allocate an endpoint name and
return it as SpecificEndpointId parameter in the CRCX response.
Change-Id: I704bbe4e11b27e83a6ae6a71aa6a715dc8301f34
A given MGCP_ConnHdlr is handling multiple connections on one Endpoint
anyway, and the variable is not set or used anywhere.
Change-Id: If9eea3f665289a52915f114f0a69234aad28f322
We shouldn't "pass" f_establish_fully() in the assignment case
as long as the old RF channel hasn't been released via RSL.
Change-Id: If7c7c8c4826feba47f8a0395c291157a0e48cd9d
This adds code for the rather intricated and nested transactions
happening on RSL, BSSAP, MGCP and RSL-IPA. We use explicit
invocation of altsteps to simplify the main function f_establish_fully.
Change-Id: I5f830b010ea1b466ae74fa810df86638a74a3b8b
During assignment or hand-over, a given TTCN-3 component may be
interested in registering more than one channel number. Add an explicit
procedure port with associated registration procedure, similar to what
we already do in GSUP, MNCC and others.
Change-Id: Iba37bf9541c779b79e179f995cdfa677633fadeb
There are quite a number of non-transparent RLL messages, such as
RLL_RELEASE_REQ. Make sure we match those as intended.
Change-Id: I30260a57fc01613450e6ac66e0af97c29041b4fa
The point of this test is to verify that *no* paging messages are sent
if "No cell" is given as cell identifier list by the MSC. We can thus
not use the existing pageing_helper function, but have to handle this
a bit differently.
This makes TC_paging_imsi_nochan runs pass.
Change-Id: Iec1086bd42f42de1986bb00b91af718977f73b30
There's no point in listing non-existing module parameters. Instead,
list those that the BSC testsuite actually has
Change-Id: I3cb756750cafba4ca481a0a98d19e27cb58395df
This test case was incomplete in that it didn't account for a RLL REL
REQ/RESP before RF_CHAN_REL.
Together with OsmoBSC Change-Id
I64a46b5bcd4272e3fa2ff4ee824c2f3fdff6854b, this test now passes.
Change-Id: Ia5af254d4fc572c1d324f70b5ec99d87bdaf9eb9
This test case was incomplete in that it
* applied the wrong timeout T3101 instead of T3210
* didn't account for a RLL REL REQ/RESP before RF_CHAN_REL
Let's fix it. Together with OsmoBSC Change-Id
Ie11d7d06353ba1b1e2fab6763dd7b032ce8a5d2c this check now actually
passes for the first time.
Change-Id: I9ed41d246cf153735fd4e71cc6cc174ede32a76b
In OsmoBSC Change-IdI68286d26e2014048b054f39ef29c35fef420cc97 we
introduce a proper subscriber connection state machine which fixes
the order of events during channel release after connection failure.
Change-Id: Ibe9c3205ec11dafcc305ea72aeb33e9152a6458c
When Change-Id I10fc9f60c58c6b7ed424a86ce23bf6b9802c9eb1 was merged,
OsmoBSC started to always allocate SDCCH first, no matter what the
establishment cause. This basically means we don't do very early
assignment anymore. TC_exhaustion must be adapted to allocate all
SDCCH and all TCH before failing.
Change-Id: I9d8bbfca0deebc738385f2a1a20d4a17c3853082