Author SHA1 Message Date
Vadim Yanitskiy 6ef5dfab86 BSC_Tests: add TC_rll_{rel_ind,err_ind,timeout}_sapi_n_reject
The idea of these new test cases is to verify that the IUT does
send BSSMAP SAPI N Reject in the following cases respectively:

  - on receipt of an unexpected RLL RELease INDication message
    in response to RLL ESTablish REQuest (for SAPI=3 link);

  - on receipt of an unexpected RLL ERROR INDication message
    in response to RLL ESTablish REQuest (for SAPI=3 link);

  - due to SAPI=3 link establishment timeout.

Change-Id: I00489e2af3befe5780380f64b09fb01e726c8df5
Related: SYS#5047, OS#4728
2020-08-29 01:50:10 +07:00
Philipp Maier 8281200718 BSC_Tests: test emergency call preemption
Fill all channels of the BTS and then try to do a channel request for an
emergency call. Osmo-bsc should pick one of the TCH channels and release
it so that there is room for the emergency call.

Change-Id: I7d544680f492cb825d909b86b2e1131ab652df13
Related: OS#4549
2020-08-24 07:36:34 +00:00
Harald Welte 65e419a085 BSC_Tests: Fix compiler warnings about inadequate template restrictions
Change-Id: I3e6e724d563993202611e73b525d5d6769bb5460
2020-08-21 13:17:59 +02:00
Daniel Willmann ebdecc0309 bsc: Add statsd checker and use it in TC_assignment_sign
Related: SYS#4877
Change-Id: I8526b645dc4af59adcc1855699421a026f505c1d
2020-08-13 15:02:15 +00:00
Neels Hofmeyr 74083c2f84 bsc CBSP: fix osmo-bsc.cfg to contain 3 BTS with a CBCH
The bsc/BSC_Tests_CBSP.ttcn rely on a configuration where the first three BTS
carry out SMSCB messaging, and the fourth BTS does not. That requires a CBCH
channel config on bts 0, 1, 2.

Side effects:

- adjust the number of available SDCCH (for TC_chan_exhaustion).

- there now is a CBCH channel description in SI4, add this to
  SystemInformationConfig_default.

Related: Idbcc703ace7012fb395f0eef3e445df28b368d74 (docker-playground)
Change-Id: Iac46ee2cc5bc0978d5f5baa550baf493a7c56b1b
2020-08-13 05:36:26 +00:00
Neels Hofmeyr 8f57671960 bsc: fix f_vty_msc_allow_attach(): do not create new empty mscs (fix latest)
In the ttcn3-bsc-latest tests, there are no 'msc 1' and 'msc 2' configured, so
stepping into 'msc 1' and '2' creates two new, empty MSC configurations.
osmo-bsc latest actually still tries to use them and fails 2/3 Compl L3.

So do not step into 'msc' config scopes if no such MSC is mentioned in the
running config yet.

This should finally fix the bsc latest tests after I broke them in
I02ad58ed7d0d0aac61e393b415e09c6c5c8a70ca and
Ibd5adb359b3fb302e2c70700d911878aef605ff3 and
I75295d638072df9f5213a7e74e4a960c009c2865.
Yes, I know :/

Change-Id: Ibfeeea98c2a962dec58ad03beb35bb7f83cad228
2020-08-12 22:54:09 +00:00
Neels Hofmeyr 95a5edc308 bsc: test RR Channel Release cause codes from Clear Command cause codes
Invoke Clear Command with various Cause codes and verify that the RR Channel
Release reflects them.

Depends: I734cc55c501d61bbdadee81a223b26f9df57f959 (osmo-bsc)
Change-Id: Ie6c99f28b610a67f2d59ec00b3541940e882251b
2020-08-12 18:21:24 +00:00
Neels Hofmeyr 0edf4ac242 bsc: test RR Channel Release EARFCNs
Add a DCHAN and release to recently added SI2quater tests (because these tests
already configure various amounts of EARFCNs in osmo-bsc).

Verify that the RR Channel Release for CSFB contains all configured EARFCNs.

In GSM_RR_Types.ttcn, add coding for "Cell selection indicator after release of
all TCH and SDCCH IE".

In f_expect_chan_rel(), add optional arg csfb_expect_cells, and, if present,
decode the RR Channel Release message's L3 part, and in turn the Cell Selection
Indicator Value contained. Match against csfb_expect_cells.

In f_tc_si2quater_n_earfcns(), also compose a list of EARFCNs as found in the
RR Channel Release, and pass to f_expect_chan_rel().

Depends: I59e427e4ebb1c6af99b27a15c40fed82457ac8ab (osmo-bsc)
Change-Id: I882c5e1f70bcc4833fc837a95c900ce291919cc5
2020-08-12 18:21:24 +00:00
Philipp Maier 606f07d113 BSC_Tests: Make sure CHAN RQDs for emergency are denied
Test that a CHAN RQD that indicates an emergency call is rejected if
emergency calls are disabled.

Change-Id: I9084df86e8f808e3c1d948ab88e07e7458761a71
Related: OS#4548
2020-08-12 17:37:44 +02:00
Philipp Maier af58db2db9 BSC_Tests: fix TC_chan_act_ack_noest_emerg
The testcase TC_chan_act_ack_noest_emerg tests if an emergency causes a
channel assignment. This can only work if emergency calls are allowed,
but the testcase does not make sure that this actually is the case.

Related: OS#4548
Change-Id: I0ddac0ba8ed4afe993d566dcbea87cdc62ed9fe4
2020-08-12 17:37:44 +02:00
Philipp Maier 783681ce42 BSC_Tests: test handling of EMERGENCY SETUP
The EMERGENCY SETUP is an L3 message that normally gets passed through
transparently to the A interface. Nomrally the BSC will not look into L3
messages. However if EMERGENCY CALLS are allowed on a BTS or not is set
in the system information. Also osmo-bsc has the option to deny
EMERGENCY CALLS globally for all BTSs.

Since EMERGENCY CALLS are a crucial application, the BSC should not only
send the appropiate sysinfo messages that forbid emergency calling. It
should also make sure that any attempt to make an emergency call is
rejected early if emergency calls are denied.

Lets add some checks to verify that the allow/deny mechanisms for
EMERGENCY CALLS are working as expected.

Depends: osmo-bsc Ia6eb38370ce4165d221d2ffbe1cd105c0628313c
Change-Id: I486d99953529a1ce9f0a3950c9a97900922eee92
Related: OS#4548
2020-08-12 10:22:29 +00:00
Philipp Maier 9c60a6228b BSC_Tests: extend TC_chan_act_ack_noest with emergency call
TC_chan_act_ack_noest requests a channel and then releases it again.
However, this does not test yet what happens if the requestor (BTS) uses
a request reference that indicates an emergancy call. Depending on the
configuration the BSC should reject or allow the channel to be
established.

Change-Id: If828c0f5786d89efa7608f38d648e2a2b8f6f675
Related: OS#4549
2020-08-11 17:07:41 +00:00
Neels Hofmeyr a460f1f9ba fix mscpool cleanup (fixes LCLS tests)
osmo-bsc takes a while to notice that a connected MSC is no longer connected.
Once the mscpool tests have run, the additional msc 1 and msc 2 still linger
around even though the BSSMAP link is no longer served by the bsc-tester.

The easiest way to ensure that only expected MSCs are contacted is to set
'no allow-attach' for each MSC that should not be in use.

So, the default setup is 'allow-attach' on msc 0, and 'no allow-attach' on mscs
1 and 2. In f_init(), allow attach on those MSCs indicated by the nr_msc
amount. The entire vty transaction to configure attach/no attach for all three
MSCs takes about 4 micro seconds in my test setup, so it is fine to do this
during f_init() for each BSC test.

After this, tests running after the MSC pooling tests (the LCLS tests) no
longer round-robin their subscribers across disconnected MSCs.

NOTE: it would be good to somehow detect more reliably in osmo-bsc that an MSC
is gone and not use it anymore. That is however not so trivial. To get the LCLS
tests back online, this is a workaround to avoid that complexity for now.

Change-Id: I02ad58ed7d0d0aac61e393b415e09c6c5c8a70ca
2020-08-10 20:16:09 +00:00
Pau Espin c6136cd4e4 Introduce test TC_si_acc_ramp_rotate
Change-Id: I29acf4f117ccea53028c780cc9feb1da1fc16739
2020-07-30 11:27:10 +00:00
Pau Espin 85a8443c3c bsc: Introduce test TC_si_acc_rotate
Related: SYS#4911
Change-Id: I18d0243353fce547d126d62c34415628a21cb52b
2020-07-24 11:05:44 +02:00
Neels Hofmeyr 56f2478e9c bsc: SI2quater EARFCNs: span entire value range of EARFCNs
Change-Id: I992771826d57669d06887c776303f85ef22f6c71
2020-07-09 13:27:50 +00:00
Neels Hofmeyr ad132f286e bsc: more SI2quater EUTRAN ARFCN tests
Add more EUTRAN ARFCNs, reaching the maximum allowed amount.

Add tests with 12, 23, 42 EARFCNs, just for the sake of testing some arbitrary
numbers.

Add tests with 32 and 33 EARFCNs because before osmo-bsc
Iabeed10053ee5899b4def3509aedd25abb2410a9, only 32 EARFCNs could be stored by
osmo-bsc.

Add a test with 48 EARFCNs to verify the maximum amount of EARFCNs and maximum
amount of SI2quater multiplexes works as expected.

Add a test with 49 EARFCNs to verify the VTY error response when adding too
many EARFCNs, and showing that osmo-bsc still sends 16 SI2quater with 48
EARFCNs.

Depends: Iabeed10053ee5899b4def3509aedd25abb2410a9 (osmo-bsc)
Change-Id: I99bf9b3381812d1db6fd0757f65995bae48da776
2020-07-09 13:27:50 +00:00
Neels Hofmeyr 66aeba4c9a bsc: add SI2quater tests for multiple EARFCNs
Shows bug OS#4652 in osmo-bsc, fixed by
I5df269f713456a6ccbb874d6b7faac4a6f123c67

Change-Id: I45382f88686ca60e68569e93569fc4cfb63a0e0d
2020-07-09 00:26:27 +02:00
Neels Hofmeyr 5e686dce2d bsc: add first test to verify System Information on RSL startup
Change-Id: I6a8ef404087efee491390dc1d2452ac323f145f0
2020-07-09 00:25:47 +02:00
Neels Hofmeyr 666f043de6 bsc: change f_bts_0_cfg() to take a VTY port arg
Remove the 'runs on' clause, add a VTY port argument.
That allows using this function also on the test_CT.

Will be used by upcoming System Information tests.

Change-Id: Ib059d9690f92f5f76025bca2b84496716a2a4cf0
2020-07-08 15:27:50 +00:00
Neels Hofmeyr 0b7365bb57 bsc: split f_init_bts() from f_init()
For SI tests, it is necessary to first startup the VTY, then issue some config
commands, and only then start up the BTSes. By this separation that can be done
by:

  f_init(nr_bts := 0);
  f_vty_transceive(...);
  f_init_bts(bts_idx := 0);

Will be used by upcoming System Information tests.

Change-Id: I24afb07735c3827f52760214fcb7a239190c3402
2020-07-08 15:27:50 +00:00
Neels Hofmeyr 9656e923bf fixup for Osmocom_CTRL_Functions: rate counters in bulk
At the time of writing Ief0d9b096feeee7d37b5f2429dd3e80de0161806 I wasn't aware
of the 'inout' keyword, which allows to pass the counter list by reference.

Rather modify the counter lists in-place. Instead of requiring

  list := f_counter_name_vals_add(list, ...)

rather implement by directly modifying list:

  f_counter_name_vals_add(list, ...)

Change-Id: I85ac56b042fe4bb1db392c1f451c8e900582cc2a
2020-06-30 04:24:59 +02:00
Neels Hofmeyr 22c3f79c98 bsc: MSC pooling: also test rate counters
Use new f_counter_* functions to verify osmo-bsc MSC pooling counters.
This nicely also verifies the intended effect of each test in detail.

Depends: I2ded757958dfa62b502efbab765203bcadf899e2 (osmo-bsc)
Change-Id: I2006f1def5352b4b73d0159bfcaa2da9c64bfe3f
2020-06-25 20:13:11 +00:00
Harald Welte eddf0e9e10 bsc: Add CommonID Test: Send CommonID from MSC and check it is processed
Related: OS#2969
Change-Id: I501108bc6c19b17d3fc680211c7290a31770a159
2020-06-23 20:08:58 +00:00
Harald Welte cb0cc4377c bsc: Sync osmo-{bsc,stp}.cfg with docker-playground.git
It appears some changes were made only to the files in
docker-playground.git, but not here.  This means that running
tests locally produced unexpected results.

We must always ensure that the tests run both without and with
docker, which means making sure the configs are all maintained!

Change-Id: I3a3f4c572b8a390882fb8f12807018ca19e4827c
2020-06-21 20:28:16 +02:00
Neels Hofmeyr f2b88032f6 bsc: set longer T_guard for TC_ho_neighbor_config tests
They perform several handover runs and tend to timeout prematurely on my
machine.

Change-Id: I9d641c9b5d5a6f2c2edbc2c782f33872cf7a483f
2020-06-20 21:43:21 +02:00
Neels Hofmeyr 4fbad7fc1a bsc: allow individual T_guard timeout via f_init()
The TC_ho_neighbor_config_* tests sometimes take longer than 30 seconds,
because they run multiple handovers. Since they don't have access to the
Test_CT, they cannot restart the T_guard. The simplest solution is to choose a
longer T_guard timeout for those tests specifically, by adding an argument to
f_init(). (A longer timeout for those tests is following in another patch.)

Why f_init()? Assigning a different default value to T_guard seems to not be
possible, but a different timeout value can be passed to T_guard.start(), which
happens in f_init().

Change-Id: I14918f6a44d6fa1bd5c3e133757ebdbe32813b33
2020-06-20 21:43:21 +02:00
Neels Hofmeyr 90f8096890 bsc: undup pars.sccp_addr_msc and _bsc
Handover testing required passing MSC and BSC addresses to f_tc_* functions and
added pars.handover.sccp_addr_msc and .handover.sccp_addr_bsc.

MSC pool tests added a separate sub-record pars.mscpool which also contains
these two fields.

Move them both up one level, to form a single pair of pars.sccp_addr_msc and
pars.sccp_addr_bsc.

This eliminates the pars.handover sub-record.

Change-Id: Iae81ca58001455099218ce769a97dc6402832490
2020-06-20 21:43:21 +02:00
Neels Hofmeyr 4f11841173 bsc: add MSC pooling tests
The MSC pooling feature is implemented in osmo-bsc
Ifbdea197b26e88751a391c8a80c41f04e7d5e047.

A VTY command ('mscpool roundrobin next') that allows deterministic testing is
added in I2155d906505a26744966f442ffb1e87a6a9b494c.

osmo-bsc.cfg changes needed for these tests to succeed are in docker-playground
I1986e4ef43beee161c82193694421b56136c1afe

The new tests will fail until the above have been merged.

Change-Id: I21cbab193cd0de2e5692665442eae113d5f61904
2020-06-18 11:54:47 +00:00
Neels Hofmeyr f246a925e8 bsc: allow multiple MSCs
Similar to the MSC tests, have several g_bssap and mp_bssap_cfg.
Prepare for MSC pool tests.

Replace g_bssap with a g_bssap[NUM_MSC] array.
Replace mp_bssap_cfg with an mp_bssap_cfg[NUM_MSC] array.

Requires patch I1986e4ef43beee161c82193694421b56136c1afe in docker-playground
to match the new required BSC_Tests.cfg format.

Related: OS#3682
Change-Id: Ibb36695b7c31f7b04eec6c5d59522fc0779b3c2f
2020-06-14 11:01:34 +00:00
Vadim Yanitskiy 9b4e356886 library/IPA_Emulation: assume TRX#0 in ASP_RSL_Unitdata templates
Change-Id: I93297680a2644516870222c2bb8eee03c6b575a9
2020-05-25 22:14:04 +07:00
Vadim Yanitskiy a2afacc905 library/IPA: use tr_ASP_IPA_EV instead of inline templates
This way we can easily add new parameters to ASP_IPA_Event.

Change-Id: Icc37286fcb4d43836d56a26424ecb9dcba58d1f1
2020-05-18 21:16:35 +07:00
Neels Hofmeyr b3fc898c2d bsc: make ho_config_tests more robust against timing
In f_probe_for_handover disable the RSL emulation before the vty handover
command.  Otherwise, osmo-bsc may be too fast to issue the handoverCommand, so
that RSLem still handles it and says: "RSL for unknown Dchan".

(f_probe_for_handover() receives the handoverCommand directly, just to detect
whether a handover would be initiated, and then quickly aborts the handover
procedure.)

Related: OS#4264
Change-Id: I7f73ef8cbdf46e31a46c9e1b7ad0fa2bd41c0a12
2020-05-11 17:27:59 +00:00
Vadim Yanitskiy cc4623dff2 library/RSL_Types: use MobileIdentityLV for MS Identity IE
Change-Id: I5436dcbbc961d5b572e10e4f1a3f806d252d7818
2020-03-28 06:21:02 +07:00
Vadim Yanitskiy 98bb2d5eea library/GSM_RR_Types: do not duplicate Mobile Identity records
All the records related to Mobile Identity IE (see 3GPP TS 24.008,
section 10.5.1.4) are defined in [1], so there is no real need to
dumplicate them. Moreover, most of the related templates in
library/L3_Templates.ttcn are based on these records.

[1] titan.ProtocolModules.MobileL3_v13.4.0/src/MobileL3_CommonIE_Types.ttcn

Change-Id: I27c2743c59db770d6f7e9447dc8c1f539b228ced
2020-03-28 03:29:22 +07:00
Pau Espin c675b6119c bsc: Introduce test TC_chan_rel_sccp_tiar_timeout
Verify SCCP T(iar) timeout triggers release of established channel.

Change-Id: Ic2724f62689b99c33e2e5c3a0c2fd022178a788c
2020-01-12 13:11:39 +00:00
Pau Espin 8f77363ea3 bsc: Verify presence of MS Power Parameters IE on one test
Otherwise most tests in bsc-latest fail because in latest release BSC
never sends that IE.

Related: OS#4244
Change-Id: I725836784a7900d2ea51eae188c2c279e8639dbf
2019-11-05 19:32:34 +00:00
Pau Espin 8f30ccdc28 bsc: Allow setting expected ms max power level with module param
It will allow changing ms max power in osmo-bsc.cfg as well as TTCN3
expactancies in BSC_Tests.cfg easily in docker-playground.git without
needing to recompile or change code in TTCN3.

Change-Id: Ib00c96902377582bc32778c5b947a6b4274041aa
2019-11-05 19:31:50 +00:00
Oliver Smith 92c2bdb00f bsc: f_ipa_unknown_unit_id: use different id
Change the unit_id value, that is supposed to be unknown at BTS, from
0/0/0 to 99/0/0 to make TC_oml_unknown_unit_id pass again. The test was
failing, because a new bts that matches 0/0/0 was added to osmo-bsc.cfg
in [1], [2] and [3].

[1] Ia4ba0e75abd3d45a3422b2525e5f938cdc5a04cc
[2] I1c57a04747f5ec004ccf4657954dcb0b003c24fc (docker-playground)
[3] I00547dccf8908d46df4730cb513fe577956d7683 (docker-playground)

Related: OS#4156
Change-Id: I585ff825c7b6bca17e5c6fb6d670a649965a1653
2019-08-20 15:30:41 +02:00
Oliver Smith 75aa020da5 BSC_Tests: update number-of-bts to 4
Fix failing TC_ctrl test for ttcn3-bsc-test and -latest.

Depends: I00547dccf8908d46df4730cb513fe577956d7683 (docker-playground)
Related: OS#4156
Change-Id: Ie2c664ba0f845da644e20e2c919c12d8fc2af6ba
2019-08-19 14:30:50 +02:00
Philipp Maier f45824ad0e BSC_Tests: Change test-expectation of TC_paging_resp_unsol
The testcase TC_paging_resp_unsol expects the BSC to close the channel
when an unsolicit paging response is received. This expectation is due
to the fact that osmo-bsc supports multiple MSC, which is not specified
in 3gpp specs. Therefore the BSC needs to know which MSC is in charge.

However, with MT-CSFB calls it is a normal situation that the BSC
receives a paging response on abis without sending a paging first since
the MSC has paged the UE via the SGs interface. In those cases we expect
the BSC to forward the paging response to the first configured MSC.

Related: SYS#4624
Change-Id: I5562cbf61a2aa42e6950860bc0f9c6c20c61a9fe
2019-08-18 17:13:20 +00:00
Neels Hofmeyr 7e2769f3b1 fix TC_ho_int; make neighbor config more robust
Since osmo-bsc commit "neighbor config: allow re-using ARFCN+BSIC pairs"
(I29bca59ab232eddc74e0d4698efb9c9992443983), osmo-bsc considers only those
cells as neighbors that are explicitly listed, or all local cells if none are
listed. This lead to breaking TC_ho_int, because the osmo-bsc.cfg has only one
remote-cell neighbor for bts 0, and hence a handover to local cell bts 1 is now
regarded as invalid.

The remote-cell neighbor is needed for inter-BSC handover tests; also consider
that the TC_ho_neighbor_config_* tests each place individual neighbor
configuration by live VTY interaction.

Hence make all of these tests more robust: remove the neighbor config from the
osmo-bsc.cfg file, and instead include VTY interaction for each test case that
sets the particularly needed neighbor configuration at runtime.

An analogous osmo-bsc.cfg change in docker-playground is in change
If44dd6b578cdc55076c8180707d1c2d69fe5f2a8.

(It is not actually harmful to leave the neighbor config in osmo-bsc.cfg, but
remove that since it is also not needed anymore.)

Change-Id: If44dd6b578cdc55076c8180707d1c2d69fe5f2a8
2019-08-15 01:07:40 +02:00
Neels Hofmeyr 9140101cb0 bsc: add TC_ho_neighbor_config_1 thru _7
Add tests to play through various neighbor configurations.
Tests will pass as soon as osmo-bsc I29bca59ab232eddc74e0d4698efb9c9992443983
is merged.

Add RSL2 to allow triggering handover to BTS 2.

Adjust osmo-bsc.cfg to match the new tests. Also applied in docker-playground
I1c57a04747f5ec004ccf4657954dcb0b003c24fc.
    - Actually enable handover.
    - Add bts 3

Depends: osmo-bsc I8623ab581639e9f8af6a9ff1eca990518d1b1211 ('no neighbors')
Related: OS#4056
Change-Id: Ia4ba0e75abd3d45a3422b2525e5f938cdc5a04cc
2019-08-13 21:54:55 +00:00
Neels Hofmeyr d8a602cbd4 rename TC_ho_out_fail_no_ho_detect to TC_ho_out_fail_no_result_after_ho_cmd
Change-Id: If84a1d4535ee12e33a50588e178bf1ebb6fb2cd5
2019-07-14 00:10:04 +00:00
Neels Hofmeyr e1797aab91 f_tc_ho_out_fail_no_ho_detect: stricter ordering
Make sure that the RR is released only after the MSC has sent the Clear Command:
- first expect a Clear Request from osmo-bsc and return a Clear Command,
- only then accept RR release messages.

See 3GPP TS 48.008 3.1.5.3.3 "Abnormal Conditions": "The terrestrial resource
in the old BSS shall remain assigned until a CLEAR COMMAND message is received
from the MSC"

osmo-bsc already complies, the test should continue to pass.

Change-Id: Iba05336d3c4af8a1c57cdc828dae464eae3510b9
2019-07-09 19:42:58 +02:00
Neels Hofmeyr 10f2bfa444 comments: BSC_Tests: clarify f_tc_ho_out_fail functions
Change-Id: Ia0584324476d36077e92d1564d9d7e79a069addf
2019-07-09 19:42:58 +02:00
Pau Espin 7aa0274138 bsc: Do proper chan release in TC_ho_out_fail_no_ho_detect
BSC waits to receive a ClearCommand in response to its ClearRequest
before it starts tearing down the MGCP conn on the MSC-side of the MGW
endpoint.

As a result, expected DLCX was not being sent which made test fail.

However, currently test still fails because current osmo-bsc master
sends a repeated ClearRequest message in this scenario.

Related: OS#4078
Change-Id: Ic398896147a0b6b04ffeae56a23d25783b2b17fe
2019-07-03 12:20:16 +00:00
Pau Espin 54ab92f787 cosmetic: bsc: Document timer timing out in f_tc_ho_out_fail_no_ho_detect
Change-Id: I4d06fcff63d82f849da08f509b007cb19e809fb0
2019-07-01 10:35:36 +00:00
Pau Espin fd02ad474e bsc: Test MGCP-over-IPA forwarding in SCCPlite tests
* MGCP-over-IPA handling in MSC_ConnectionHandler means we need to use
the new MGCP_CLIENT_MULTI port since we'll be managing MGCP messages
from 2 different UDP connections, and we need to be able to route
answers correctly. As a result, parameter multi_conn_mode is enabled for
SCCPlite and all code adapted to use that port in that type of scenario.
* iDuring calls when on SCCPlite, send a full (all-required-params-in)
CRCX through the MGCP-over-IPA connection towards the BSC in order to
emulate the MSC, and expect the correct answer back. This way we test
BSC funcionality to forward MGCP messages coming from MSC works as
expected.

Related: OS#2536
Depends: osmo-bsc.git I38ad8fa645c08900e0e1f1b4b96136bc6d96b3ab
Change-Id: I31fed700772dd0b063f913b1e1639fd428c46e7d
2019-06-24 13:53:25 +00:00
Pau Espin 1a026a52d3 lib/mgcp: Add new port with support to handle multiple MGCP sockets
* Some scenarios like MGW BSC-attached in SCCPlite require handling of
2 MGCP-over-UDP sockets in MGCP Emulation: 1 for regular
libosmomgcp-client from osmo-bsc and another one from the forward socket
from osmo-bsc (of MGCP-over-IPA messages communicated with MSC).

* Old port is kept for backward compatibility with other tests and
enabled by default. It's also interesting to keep it because it makes
tests without special needs (2 sockets) to use the old port/API which
produces simpler code to read and mantain.

* Users of the new port have to enable multi_conn_mode parameter and
expect to interact with port MGCP_CLIENT_MULTI instead of MGCP_CLIENT,
which will offer messages containing information about the UDP
connection being used by that message.

Change-Id: Ic0ba8c5cde068c07671512a83095d83e28b86746
2019-06-24 13:53:25 +00:00