If the EF.EHPLMN exists, it contains the "Equivalent Home PLMN List".
The odd part of that list is that it is not just a list of additional
PLMN identities, but if the first digits of the IMSI are *not* listed
in EF.EHPLMN, then the MCC/MNC of the IMSI prefix is suddently no
longer considered the home network, but the subscriber is roaming.
See TS 23.122: "If the HPLMN code derived from the IMSI is not present
in the EHPLMN list, then it shall be treated as a Visited PLMN for PLMN
selection purposes."
Change-Id: I22d96ab4a424ec5bc1fb02f5e80165c646a748d3
When writing to files we often just write without making sure that the
actual file contents actually written. Lets add features to do a
read-after-write verification when writing to files.
Change-Id: I7be842004102f4998af376790c97647c107be3d5
For record oriented files we have the methods record_size() and
record_count() to determine the dimensions of a record oriented file,
however, we miss a similar function for regular binary files. Lets add a
method binary_size() to quickly determine the size of a non record
oriented file
Change-Id: I0593f2de7f34d5654a19e949dc567a236e44e20c
Unlike Python 2, in Python 3 strings also have attribute '__iter__'.
Because of that, a string could be passed to select_file(), that
actually expects a list as the first parameter.
P.S. Madness, Python 3 is just a new different language...
P.P.S. They should have renamed it not to confuse people.
Change-Id: I92af47abb6adff0271c55e7f278e8c5188f2be75
Fixes: OS#4419
In Python 3, traditional division operator returns a float,
while we need a floor integer in the most cases.
Change-Id: I5565eb64a1ddea7075cbb142eaacaa5d494c87bb
The sysmo-isim-sja2 cards are not yet supported by pysim. Lets add
support for writing KI and OPC in ADF.USIM and ADF.ISIM as well as the
remaining common simcard parameters.
Related: SYS#4466
Change-Id: I23e2b46eac0e0dbc2b271983d448999f6a459ecf
When working with USIM/ISIMs, The method __record_len() that is used
by the record_count() method returns the length of the file instead
the actual record count. This causes record_count() to return always 1
Change-Id: If810c691893c022e9e9d87218dd0a334c5b2d579
Without that fix we have:
$ python3 pySim-read.py
File "pySim-read.py", line 135
try:
^
TabError: inconsistent use of tabs and spaces in indentation
The following command was used to do the conversion:
sed 's# #\t#g' -i $(find -name "*.py")
Then the remaining spaces spotted during the review were
addressed manually.
Signed-off-by: Denis 'GNUtoo' Carikli <GNUtoo@cyberdimension.org>
Change-Id: I83f76a8e9b6e36098f16552a0135a8c22dde545f
The hexadecimal tag defintions of pytlv are case sensitive strings. So
'A5' is something different than 'a5'. Pytlv uses lower case letters for
the upper hexadecimal digits. Lets correct this.
Change-Id: I41a9933707783f6b1b68ebd91a365405ac0892d0
Related: OS#3850
Some of the USIM-Card programming implementations do not need to look
at card responses, which means they also do not have to parse TLV
data. Lets depend on pytlv only in cases where TLV data has to be
parsed so that useser of cards that do not need at can go without
installing pytlv.
Change-Id: Ida841d74d9581e7f395751b0f74556a06a038de6
Some of the methods SimCardCommands() have ways to determaine length
information from the card response. Regular sims use a format where
the length field is on a fixed position. USIMs use FCP templates
(format control parameters), which is a TLV encodecs string. So lets
distingish if we deal with an USIM (We can easily do this by looking
at the select control parameters) and extract the length info from
the FCP.
- If we deal with USIMs, use the FCP to determine length
information
Change-Id: I068cf8a532e1c79a2d208e9d275c155ddb72713c
Related: SYS#4245
sysmo-usim-sjs1 requires P2 to be set to 0x0C (request FCI) when
using the USIM application commands. The FCI is not used by pysim
anyway and might even cause problems with other cards.
This commit adds a pair of get/set methods to the SimCardCommands
class in order to set a default for the selection control
parameters (P1, P2). (Similar to the set/get methods for the class
byte)
The SysmoUSIMSJS1 class now calls the setter method for the
selection control parameters inside of its constructuor and sets
the selection control parameter default to "000C". This way we
can be sure that we only change the behaviour for sysmo-usim-sjs1
and do not break support for any other cards.
Change-Id: I1993a267c952bf37d5de1cb4e1107f445614c17b