This will replace the hand-crafted codec for EF_SPN
by a struct definition using the construct library.
Old encoders are updated and kept for API compatibility
but are not used internally anymore.
New data structures:
* Rpad(Adapter): Right-padded bytestring (0xff, adjustable)
* GsmStringAdapter(Adapter): Codec for "SMS default 7-bit
coded alphabet as defined int TS 23.038" using
the gsm0338 library.
* GsmString(n): Convenient wrapper of both above
Adjustments:
* utils: update+deprecate old dec_spn(), enc_spn()
* remove refs to deprecated functions
Change-Id: Ia1d3a3835933bac0002b7c52511481dd8094b994
The encoder for EF_SPN is passing the 'spn' parameter (which is a list)
directly to enc_spn without taking it apart first.
Change-Id: I0a405793c8909d4279e634b93dcb76e5cb2963f3
Related: OS#4963
This adds support for a new EF file type: BER-TLV files. They are
different from transparent and linear fixed EFs in that they neither
operate on a byte stream nor fixed-sized records, but on BER-TLV encoded
objects. One can specify a tag value, and the card will return the
entire TLV for that tag.
As indicated in the spec, the magic tag value 0x5C (92) will return a
list of tags existing in the file.
Change-Id: Ibfcce757dcd477fd0d6857f64fbb4346d6d62e63
The Access Mode (AM) and Security Condition (SC) DOs are incredibly
convoluted, so we need a lot of code to properly decode them.
Change-Id: If4f0725a849d41fd93de327ed00996d8179f2b0e
This will allow us to match INS -> name and add more related
bits in the future (e.g. for decoding APDU traces)
Change-Id: I314ff15186dc05778ea12363cac0a310b6c7713c
Represents DataObject (DO) in the sense of ISO 7816-4. Contrary to
'normal' TLVs where one simply has any number of different TLVs that may
occur in any order at any point, ISO 7816 has the habit of specifying
TLV data but with very specific ordering, or specific choices of tags at
specific points in a stream. This is represented by DataObjectChoice,
DataObjectCollection and DataObjectSequence classes.
Change-Id: Iac18e7665481c9323cc7d22a3cd93e3da7869deb
When the Access Technology Identifier encoder sets the bits for E-UTRAN
it does not respect that bit "100" is also a valid bit combination that
encodes E-UTRAN WB-S1 and E-UTRAN NB-S1. Lets encode this bit
combination if the user is just specifying "E-UTRAN" without further
spefication of WB or NB.
The decoder only looks at bit 14 and decodes "1xx" always to "E-UTRAN".
This is not specific enough. Lets make sure that the decoder is
complementary to the encoder.
Change-Id: Ibfe8883a05f9ad6988d8e212cb9a598229954296
Related: OS#4963
The function dec_xplmn_w_act(), which is also used by
format_xplmn_w_act() is using integer numbers as MCC/MNC representation.
This causes various problems since the information about leading zeros
gets lost.
Change-Id: I57f7dff80f48071ef9a3732ae1088882b127a6d4
The dec_plmn function takes an hexstring and returns the decoded MCC and
MNC as integer values. The result is then used by the json encoder in
EF_PLMNsel, which means the json output will contrary to the input, use
integer values instead of strings.
This is not correct since there may be leading zeros (e.g. mnc 01 and
001 both exist are different) which must be retained in order to know
the correct length of the MNC.
Related: OS#4963
Change-Id: I393e04836814d992d2a6d0a4e4e01850976d6e81
To prevent missunderstandings when using enc_plmn(), specify the input
and return parameters as Hexstr.
Change-Id: I57cf8e2de357650aef2a06fbffc7615ccb2a45b4
Related: OS#4963
Previous implementation waits 300ms for response after
each command issued. But many commands finish earlier.
This patch improves the command execution time by frequently
checking for the response to complete (i.e. ends with
OK or ERROR), or the occurence of a timeout (default 200ms).
Timeout can be adapted per command to support long response
times of certain commands like AT+COPS=? (network search)
Execution time benchmark (20 AT commands/responses):
Previous: 6.010s (100.0%)
New code: 0.045s ( 0.7%)
Change-Id: I69b1cbc0a20d54791e5800bf27ebafc2c8606d93
Let's just use the scope limited TemporaryDirectory() instead, so
the temporary directory will be removed by Python automatically.
pySim/filesystem.py:679:16: E0602: Undefined variable 'shutil' (undefined-variable)
Change-Id: I4ea833fd79f4342c33899124379be509ba1e35ed
pySim/transport/__init__.py:86:15: E1101:
Instance of 'LinkBase' has no '_send_apdu_raw' member;
maybe 'send_apdu_raw'? (no-member)
Change-Id: I14fcdceca5d1e35491b6ad98f96b4276b69b2fc1
This method has been removed [1] in Python 3.0:
pySim/cards.py:581:14: E1101: Instance of 'dict' has no 'iteritems' member (no-member)
pySim/cards.py:591:24: E1101: Instance of 'dict' has no 'iteritems' member (no-member)
[1] https://wiki.python.org/moin/Python3.0#Built-In_Changes
Change-Id: Iba7ad9ed2a9b197ecedaaed1c6744fe1c721515a
Fixes the following pylint's warnings:
pySim/cards.py:494:18: E1101: Class '_MagicSimBase' has no '_files' member (no-member)
pySim/cards.py:509:6: E1101: Instance of '_MagicSimBase' has no '_files' member (no-member)
pySim/cards.py:529:26: E1101: Instance of '_MagicSimBase' has no '_files' member (no-member)
pySim/cards.py:537:5: E1101: Instance of '_MagicSimBase' has no '_ki_file' member (no-member)
pySim/cards.py:547:5: E1101: Instance of '_MagicSimBase' has no '_ki_file' member (no-member)
pySim/cards.py:548:8: E1101: Instance of '_MagicSimBase' has no '_ki_file' member (no-member)
pySim/cards.py:559:26: E1101: Instance of '_MagicSimBase' has no '_files' member (no-member)
pySim/cards.py:560:11: E1101: Instance of '_MagicSimBase' has no '_files' member (no-member)
pySim/cards.py:576:14: E1101: Instance of '_MagicSimBase' has no '_files' member (no-member)
Change-Id: I4db9d21258d6e04140962134c540e36631466322
pySim/card_key_provider.py:67:2: E1111:
Assigning result of a function call, where the function
has no return (assignment-from-no-return)
Change-Id: I43bab69f53300fbe837944735cd999fab5405d7a
Some modems may reject AT+CSIM if PDU contains lower
case hex digits [a-f]. Modem response is "ERROR"
without any error code.
This patch converts each PDU to upper case.
Tested with Sierra Wireless EM7565.
Example:
AT+CSIM=14,"00a40004023F00"
ERROR
AT+CSIM=14,"00A40004023F00"
+CSIM: 4,"612F"
OK
Change-Id: I318e36abc7ae975c62d32b7fe0ec949bf5997d13
The json input that is used with EF.MSISDN seems to be somewhat
ambigious. The original code accepts {"msisdn": "+4916012345678"}
only while the output is {"msisdn": [1, 1, "+4916012345678"]}. Lets
add a check and also accept the latter version.
Change-Id: I8f8dd68aac25d3fa3bc1aab06b855f8ec6640258
Related: OS#4963
* 'String' class renamed to 'PaddedString' in construct v2.9
* 'CommandSet' was introduced with with cmd2 v1.3.0
Change-Id: I170a9e896612086c4b0535cd6d950346897abc3b
I always assumed BER-TLV files are transparent EF with BER-TLV contents.
However, this is wrong. ETS TS 102 221 Section 8.2.2.4 specifies them.
TS 102 221 Section 11.3 describes the specific RETRIEVE DATA, SET DATA
commands, which are not yet implemented in pySim.
Change-Id: Ie4701d9f72b05c8a5810e287e55a20f6ea86a574
The encoding of EF.MSISDN is a bit unstrutured. The encoder function
does not return a valid result since it lacks the parameters
Capability/Configuration2 Record Identifier and Extension5 Record
Identifier, which are mandatory but can be set to 0xFF. Also the
encoder gets its input from pySim-shell, so it should have some
more input validation, especially when the user encodes an empty
string. The encoder and decoder function also do not have unit-tests.
Since the encoder now adds the missing two bytes by isself this does
not have to be done manually anymore, so cards.py needs to be
re-aligned.
For pySim-shell.py the encoder is used from ts_51_011.py. Unfortunately
it is used wrongly there. The optional Alpha Identifier is required
here as well.
Related: OS#4963
Change-Id: Iee5369b3e3ba7fa1155facc8fa824bc60e33b55b
Now that we have a shared argparse definition for all reader related
options in the transport module, use that.
Change-Id: I12ca1a484a5d6e84820d9761c9701f8a94381f66
Ideally that shared definition would be used by all programs,
rather than copy+pasting it. Unfortunately pySim-{read,prog}
are still using optparse and first need to be converted to
argparse.
Change-Id: If77f53850e1ca65f42cf1dca3e0f460dac1b0d1a
the helpstring of update_record_decoded mentions hex bytes for the data
parameter, but it should be mentioned as abstract json data like in
update_binary_decoded
Change-Id: Ibae2ab49054ac5dd6fcccddd28c98d886403dac9
Related: OS#4963
the export summary is printed after the log entry for the last file
without separation. This is confusing because it looks like if the
summary would refer to the last file only. Lets add a headline to make
clear that the last few lines are the "Export summary"
Change-Id: I90771e525b2b114bdb41a8e90d298ca991c09c3d
Related: OS#4963
The sysmo-usim-sja2 which is currently used for testing somewhat old. In
order to have a defined state here lets exchange it with a new card.
This will also ensure that we have a card with the most recent card
profile in the tester.
Change-Id: Ife13823d0b0a16b1f327dd882f91d0c95af65e43