This change implements programming of EF.MSISDN as per 3GPP TS 31.102,
sections 4.2.26 and 4.4.2.3, excluding the following fields:
- Alpha Identifier (currently 'FF'O * 20),
- Capability/Configuration1 Record Identifier ('FF'O),
- Extension1 Record Identifier ('FF'O).
This feature is introduced exclusively for sysmoUSIM-SJS1.
Othere SIM card types need to be tested.
Change-Id: Ie033a0ffc3697ae562eaa7a241a0f6af6c2b0594
This change implements parsing of EF.MSISDN (and thus EF.ADN)
as per 3GPP TS 31.102, sections 4.2.26 and 4.4.2.3.
Example (commercial SIM card from 401/02):
EF.MSISDN: ffffffffffffffffffffffffffff07917787028982f7ffffffffffff
Decoded (NPI=1 ToN=1): +77782098287
Note that sysmoUSIM-SJS1 in the test setup has malformed
EF.MSISDN, so that's why the test output is changed.
Change-Id: Ie914ae83d787e3f1a90f9f305bffd45053b8c863
In case the MCC/MNC are not supplied with a CSV file we cut out the
missing values from the IMSI string. Lets use a function to do this and
also check the input parameters.
Change-Id: I98e5bf8f9ff2a852efb190cc789edf42c5075bf8
At the moment MNC and MCC are represented as integer numbers inside the
parameter array while all other parameters are represented as strings.
Lets use strings for MNC/MCC as well to simplify the parameter handling.
We will also not loose the length information in case of leading zeros.
Change-Id: Ia2333921a4863f0f26ee923ca796e62ec5e2d59a
Allow decoding and pretty printing of PLMNwAcT, HPLMNwAcT and OPLMNwAct.
Includes unit tests for the added functions.
Change-Id: I9b8ca6ffd98f665690b84239d9a228e2c72c6ff9
When programming or reading a SIM with an IMSI shorter than 15, the IMSI
value is incorrectly encoded/decoded.
The code pads the the IMSI value with 0xF from the left but padding from
the right would be correct.
It also encodes the length as half the number of digits in the IMSI
(rounded up). This isn't correct for even length IMSIs. With even length
IMSIs, the odd/even parity bit bumps the last digit into an extra byte,
which should be counted as well.
- Fix endcoding of IMSI value
- Fix decoding of IMSI value
Change-Id: I9ae4ca4eb7c2965e601a7108843d052ff613beb9
Patch-by: Ben Foxmoore
Closes: SYS#3552
It should fix the following observed error:
~/pysim$ ./pySim-read.py -p0
Reading ...
ICCID:
Traceback (most recent call last):
File "./pySim-read.py", line 99, in <module>
print("IMSI: %s" % (dec_imsi(res),))
File "/home/lab434/pysim/pySim/utils.py", line 57, in dec_imsi
l = int(ef[0:2]) * 2 # Length of the IMSI string
ValueError: invalid literal for int() with base 10: 'ff'
Change-Id: I7d3ecbf9edd190d1941816796cee60e3957d5943