Problem:
TA provided from L1 PH-DATA-IND is a relative amount of TA adjustment to actual TA
being used for given TBF. The current TA update algorithm in PCU simply applies the relative
amount of TA to given TBF but does not take into account of current TA.
As a result, the PCU will request wrong TA jump for given TBF if the MS is moving away from
BTS more than 2 km.
Related issue: http://osmocom.org/issues/2611
Fixes:
- The PCU needs increase or decrease current TA of given TBF on receiving of relative
amount of TA adjustment provided by PH-DATA-IND from L1.
- The PCU needs to set absolute TA of given TBF on receiving absolute TA provided by
PH-RA-IND from L1.
From-Commit: 139ad3f42193
From-Remote: https://gitlab.com/nrw_noa/osmo-pcu
Change-Id: I7665586dd5722bbe04632ee5673d3033bc082324