Blackfin: add workaround for anomaly 05000171
DESCRIPTION: The Boot ROM is executed at power up/reset and changes the value of the SICA_IWR registers from their default reset value of 0xFFFF, but does not restore them. WORKAROUND: User code should not rely on the default value of these registers. Set the desired values explicitly. Signed-off-by: Mike Frysinger <vapier@gentoo.org>
This commit is contained in:
parent
51ee6e057f
commit
ce1fe4ba6b
|
@ -355,6 +355,10 @@ void initcode(ADI_BOOT_DATA *bootstruct)
|
||||||
bfrom_SysControl(actions, &memory_settings, NULL);
|
bfrom_SysControl(actions, &memory_settings, NULL);
|
||||||
#if ANOMALY_05000432
|
#if ANOMALY_05000432
|
||||||
bfin_write_SIC_IWR1(-1);
|
bfin_write_SIC_IWR1(-1);
|
||||||
|
#endif
|
||||||
|
#if ANOMALY_05000171
|
||||||
|
bfin_write_SICA_IWR0(-1);
|
||||||
|
bfin_write_SICA_IWR1(-1);
|
||||||
#endif
|
#endif
|
||||||
} else {
|
} else {
|
||||||
serial_putc('G');
|
serial_putc('G');
|
||||||
|
|
Loading…