Fix Marvell 88e1145 PHY init code

Fix a bug in the Marvell 88e1145 PHY init code in the TSEC driver
where the reset was being done after the errata code instead of
before.

Signed-off-by: Haiying Wang <haiying.wang@freescale.com>
Signed-off-by: Andy Fleming <afleming@freescale.com>
This commit is contained in:
Andy Fleming 2007-05-08 17:23:02 -05:00 committed by Andrew Fleming-AFLEMING
parent 4ef218f6fd
commit 7507d56cca
1 changed files with 4 additions and 2 deletions

View File

@ -1037,14 +1037,16 @@ static struct phy_info phy_info_M88E1145 = {
"Marvell 88E1145",
4,
(struct phy_cmd[]){ /* config */
/* Reset the PHY */
{MIIM_CONTROL, MIIM_CONTROL_RESET, NULL},
/* Errata E0, E1 */
{29, 0x001b, NULL},
{30, 0x418f, NULL},
{29, 0x0016, NULL},
{30, 0xa2da, NULL},
/* Reset and configure the PHY */
{MIIM_CONTROL, MIIM_CONTROL_RESET, NULL},
/* Configure the PHY */
{MIIM_GBIT_CONTROL, MIIM_GBIT_CONTROL_INIT, NULL},
{MIIM_ANAR, MIIM_ANAR_INIT, NULL},
{MIIM_88E1011_PHY_SCR, MIIM_88E1011_PHY_MDI_X_AUTO,