transceiver: Fix RSP SETSLOT format

According to osmo-trx README:
SETSLOT sets the format of the uplink timeslots in the ARFCN.
The <timeslot> indicates the timeslot of interest.
The <chantype> indicates the type of channel that occupies the timeslot.
A chantype of zero indicates the timeslot is off.
CMD SETSLOT <timeslot> <chantype>
RSP SETSLOT <status> <timeslot> <chantype>

Change-Id: I63c81155c84fc35cff1704734fd8d2732235c5a4
Related: OS#2944
This commit is contained in:
Pau Espin 2018-02-14 13:19:25 +01:00
parent 39304b742a
commit 9a2d11c38c
1 changed files with 1 additions and 1 deletions

View File

@ -340,7 +340,7 @@ _trx_ctrl_cmd_setslot(struct trx *trx, const char *cmd, const char *args)
if (trx->l1l[tn])
l1ctl_tx_bts_mode(trx->l1l[tn], 1, trx->type, trx->bsic, trx->arfcn, trx->gain, trx->l1l[tn]->tx_mask, trx->l1l[tn]->rx_mask, trx->handover);
return _trx_ctrl_send_resp(trx, cmd, "%d %d", 0, type);
return _trx_ctrl_send_resp(trx, cmd, "%d %d %d", 0, tn, type);
}
static int