apps/modbus README
==================
This directory contains a port of last open source version of FreeModBus
(BSD license). The code in this directory is a subset of FreeModBus version
1.5.0 (June 6, 2010) that can be downloaded in its entirety from http://developer.berlios.de/project/showfiles.php?group_id=6120.
Directory Structure/Relation to freemodbus-v1.5.0
-------------------------------------------------
The original FreeModBus download consists of several directories. This
subset takes only the contents of one directory, modbus/, that implements
the core modbus logic and integrates that directory into the NuttX build
system. The mapping between freemodbus-v1.5.0 and the nuttx directories
is shown below:
--------------------------- ----------------------------------------------
freemodbus-v1.5.0 Nuttx
--------------------------- ----------------------------------------------
All top level .txt files Not included
demo/ Not included. This directory contains demo
and porting code for a variety of platforms.
The NuttX demo was ported from the the LINUX
demo in this director and can be found at
apps/examples/modbus.
doc/ Note included. This directory contains Doxygen
support files.
modbus/ Included in its entirety in various locations:
ascii apps/modbus/ascii
functions apps/modbus/functions
include apps/include/modbus
mb.c apps/modbus/mb.c
rtu apps/modbus/rtu
tcp apps/modbus/tcp
tools/ Note included. This directory contain Doxygen
tools.
--------------------------- ----------------------------------------------
So this directory is equivalent to the freemodbus-v1.5.0/modbus
directory except that (1) it may include modifications for the integration
with NuttX and (2) the modbus/include directory was moved to apps/modbus.
The original, unmodified freemodbus-v1.5.0 was checked in as SVN revision
4960.
The other directory here, nuttx/, implements the NuttX modbus interface.
It derives from the freemodbus-v1.5.0/demo/LINUX/port directory.
Configuration Options
=====================
In the original freemodbus-v1.5.0 release, the FreeModBus configuration
was controlled by the header file mbconfig.h. This header file was
eliminated (post revision 4960) and the FreeModBus configuration
was integrated into the NuttX configuration system.
The NuttX-named configuration options that are available include:
CONFIG_MB_ASCII_ENABLED - Modbus ASCII support
CONFIG_MB_RTU_ENABLED - Modbus RTU support
CONFIG_MB_TCP_ENABLED - Modbus TCP support
CONFIG_MB_ASCII_TIMEOUT_SEC - Character timeout value for Modbus ASCII. The
character timeout value is not fixed for Modbus ASCII and is therefore
a configuration option. It should be set to the maximum expected delay
time of the network. Default 1
CONFIG_MB_ASCII_TIMEOUT_WAIT_BEFORE_SEND_MS - Timeout to wait in ASCII prior
to enabling transmitter. If defined the function calls
vMBPortSerialDelay with the argument CONFIG_MB_ASCII_TIMEOUT_WAIT_BEFORE_SEND_MS
to allow for a delay before the serial transmitter is enabled. This is
required because some targets are so fast that there is no time between
receiving and transmitting the frame. If the master is to slow with
enabling its receiver then he will not receive the response correctly.
CONFIG_MB_FUNC_HANDLERS_MAX - Maximum number of Modbus functions codes the
protocol stack should support. The maximum number of supported Modbus
functions must be greater than the sum of all enabled functions in this
file and custom function handlers. If set to small adding more functions
will fail.
CONFIG_MB_FUNC_OTHER_REP_SLAVEID_BUF - Number of bytes which should be allocated for the Report Slave ID command. This number limits the maximum size of the additional segment in the report slave id function. See eMBSetSlaveID() for more information on how to set this value. It is only used if CONFIG_MB_FUNC_OTHER_REP_SLAVEID_ENABLED is set to 1.
CONFIG_MB_FUNC_OTHER_REP_SLAVEID_ENABLED - If the Report Slave ID function should be enabled.
CONFIG_MB_FUNC_READ_INPUT_ENABLED - If the Read Input Registers function should be enabled.
CONFIG_MB_FUNC_READ_HOLDING_ENABLED - If the Read Holding Registers function should be enabled.
CONFIG_MB_FUNC_WRITE_HOLDING_ENABLED - If the Write Single Register function should be enabled.
CONFIG_MB_FUNC_WRITE_MULTIPLE_HOLDING_ENABLED - If the Write Multiple registers function should be enabled.
CONFIG_MB_FUNC_READ_COILS_ENABLED - If the Read Coils function should be enabled.
CONFIG_MB_FUNC_WRITE_COIL_ENABLED - If the Write Coils function should be enabled.
CONFIG_MB_FUNC_WRITE_MULTIPLE_COILS_ENABLED - If the Write Multiple Coils function should be enabled.
CONFIG_MB_FUNC_READ_DISCRETE_INPUTS_ENABLED - If the Read Discrete Inputs function should be enabled.
CONFIG_MB_FUNC_READWRITE_HOLDING_ENABLED - If the Read/Write Multiple Registers function should be enabled.
Note
====
The developer of FreeModBus, Christian Walter, is still developing Modbus
libraries, although they are now commercial. See
http://www.embedded-solutions.at/ for further information.