RFC 4666 (SS7/MTP3/M3UA) states in isection 4.3.4.3 ASP Active Procedures:
"""
If the traffic handling mode of the Application Server is not already known via
configuration data, then the traffic handling mode indicated in the
first ASP Active message causing the transition of the Application
Server state to AS-ACTIVE MAY be used to set the mode.
"""
In section 3.6.1 Registration Request (REG REQ), no related information
is provided on how to handle it, but still makes sense to apply same
behavior as in 4.3.4.3.
Related: OS#4220
Change-Id: Iaebe3a93ad8d2d84ae01e41b02674f8ece9dfc95
This function is used for both actual SIGTRAN (M3UA, SUA over SCTP)
as well as for IPA/SCCPLITE (over TCP). Having a static "SCTP"
string in the log lines is confusing.
Change-Id: Ic34ddbcd528cd871d9772665e1d0863896f33203
If no IP addr is assigned yet, until know it'd print "(:3456". Let's
print ":34456" in that scenario.
Change-Id: Iae85d231093b6f3ce6b969324699858e525c14ea
After this patch, Several "local-ip" and "remote-ip" lines are accepted
under "listen" and "asp" VTY nodes, allowing to configure an SCTP
connection with multiple connections, hence allowing control of SCTP
multi-homing features.
libosmo-sccp clients such as osmo-bsc and osmo-msc also gain support for
this feature with this commit.
Related: OS#3608
Depends: libosmocore.git Ic8681d9e093216c99c6bca4be81c31ef83688ed1
Depends: libosmo-netif.git I0fe62f518e195db4e34f3b0ad1762bb57ba9d92a
Change-Id: Ibd15de7a4e00dbec78ff2e2dd6a686b0f3af22de
Commit 10d4815bb1 already fixed the issue
where binding was done during L_CS7_XUA_NODE (listen) done, meaning
local-ip inside it had no effect. In that comment, binding was moved to
happen during "local-ip" VTY cmd. Furthermore, that commit added a new
osmo_ss7_bind_all_instances() and related APIs to allow osmo-stp to have
all xua servers bound if no "local-ip" was provided.
These APIs have only been used so far by osmo-stp (which lays in the
same git repo that libosmo-sccp) since it's the only program using the
xua server features.
In the present commit, let's drop the APIs added by commit described
above, and instead let libosmo-sccp code to internally bind the xua
server upon exit of the VTY node. As a result, the previously introduced
APIs can be dropped (not used by anyone anymore) and it will provide
ways to support multiple "local-ip" commands in the future, hence
supporting SCTP multi-home features.
It's recommended to require libosmocore.git Ia6d88c0e63d94ba99e950da6efbc4c1871070012
since it fixes a bug where go_parent_cb was not called for nodes at the
end of the file.
Related: OS#3608
Change-Id: I2cff17b5e2e2fbfd4591e23a416e510e94e173d6
Consider them as lost by the lower layer, otherwise lots of old messages
and retransmissions can end up queued in there until stream becomes
connected, and then will flood the peer with all those messages.
Depends: libosmo-netif.git 962bf9a48eed418354685dc733b8271d2dd62c27
Related: OS#4188
Change-Id: Ic7d3571848faf28221dcfa8eb8b33b42964d988e
We were printing the mask of the route, but not the point code itself.
Best would probably be to print both?
Closes: OS#3835
Change-Id: Ifa4fdbad953d40f222beb470a082eed8c20991ef
"show cs7 instance 0 asp" before this patch would not display the
remote IP/port information about dynamically-added ASPs but instead:
Effect Primary
ASP Name AS Name State Type Rmt Port Remote IP Addr SCTP
------------ ------------ ------------- ---- -------- --------------- ----------
asp-dyn-0 ? ASP_ACTIVE m3ua 0 (null)
With this patch it is now correctly displayed:
Effect Primary
ASP Name AS Name State Type Rmt Port Remote IP Addr SCTP
------------ ------------ ------------- ---- -------- --------------- ----------
asp-dyn-0 ? ASP_ACTIVE m3ua 24905 127.0.0.1
Change-Id: I39a1c57bc72e8aff607f3a551811a2f6372adab4
Closes: OS#3836
Using osmo_stream_cli_open() with explicit timeout set via
osmo_stream_cli_set_reconnect_timeout() will have the same
effect. Update comment explaining this as well as the code.
Change-Id: Iffe6ea48a170880faef071c7c4a1bc0605aa9855
Previously internal function get_pc_comp_shift() returned negative error
code when called with wrong component number despite unsigned return
value which wasn't checked for error anyway.
Fix this by using explicit assert in the error path. This should not
affect external users because this function always called with constant
component argument.
Change-Id: Ib24cdbcf614bad68f3cfa9776a451c5c1e45ae6e
That's useful for external programs veryfying pointcode validity. For
example if used as part of BSS-related identity in GCR construction by
LCLS code we should be able to double.check that no significant bits off
pointcode are lost/ignored.
Change-Id: I5a9981dd2c1d78966c61a3f6b50c7c0d9b542caf
Allow callers of xua_srv_conn_cb() to tell whether conn
was freed by returning error code EBADF, which is also
used elsewhere in osmocom programs for this purpose.
This is necessary because xua_srv_conn_cb() might be running
inside of a loop which checks for read and then write events
on the connection. If the connection is freed by xua_srv_conn_cb()
as part of processing a read event, callers should avoid further
processing of events. But if we don't return an error we are leaving
callers none the wiser and with a dangling conn pointer.
Change-Id: I7359667b2f25d6c45acc70049b2a4ee2f376a1df
Related: OS#3685
Instead of allocating ss7->sccp in various places, unify that in one common
function. We shouldn't spread the decision what to pass as priv pointer around
everywhere. There is no functional difference.
This is preparation for a patch where the sccp_instance gets allocated from the
telnet VTY: I would prefer to hide all allocation details from that code; which
also makes sense for the other callers of osmo_sccp_instance_create().
Change-Id: Ie912898c66d31ce4ac8eeeea5a6ddc3f821c06f7
Applications may be interested in handling data for those SCTP PPID or
IPA StreamID which libosmo-sigtran doesn't implement
natively/internally.
Let's add osmo_ss7_register_rx_unknown_cb() using which applications
can register a call-back to implement whatever behaviour they'd want for
those PPID/StreamIDs.
Change-Id: I8616f914192000df0ec6547ff4ada80e0f9042a2
Makes sure that in absence of a user-specified port number,
osmo_ss7_asp_protocol_port() will return 5000 as default port number.
Change-Id: I628ee095603742a652fd971887e02cc17d1f71b8
In osmo-stp, cmd "local-ip" inside node "listen m3ua 2905" was actually
not being applied, because the server was created + bound at "listen" command
time using NULL as IP, and at "local-ip" time the IP was changed but the
server was not re-bound using the new IP, so it kept listening at
0.0.0.0.
With this patch, we defer binding the socket to "local-ip" cmd time,
after the IP has been applied.
As a result, if no "local-ip" command is provided, then the bind never
happens, which means it is now mandatory that users of osmo_ss7_xua_server_create
API not using osmo_ss7_xua_server_set_local_host call new provided API
osmo_ss7_xua_server_bind. Another new API osmo_ss7_bind_all_instances is
provided to easily make sure all servers are bound after configuration
process. This is specially important for servers which doesn't contain
the "local-ip" parameter.
Users of osmo_sccp_simple_server API are not affected by this change,
and they not requrie to call any new API.
Furthermore, using osmo_ss7_xua_server_bind in VTY code ensures the xUA
server is automatically bound to the new address if the operator changes
the "local-ip" cmd at runtime.
Related: OS#2647
Change-Id: I79738963d633bec70705ff159c5b2127cd498aa2
Initialize osmo_ss7_instance.cfg.primary_pc = OSMO_SS7_PC_INVALID.
Adjust all code paths using primary_pc to ensure it is indeed valid.
Rationale:
It looks like we are going to use the primary point-code of an SS7 instance to
derive a local SCCP address, e.g. for osmo-bsc and osmo-hnbgw.
cs7-instance 1
point-code 1.2.3 ! sets osmo_ss7_instance.primary_pc = 1.2.3
sccp-address msc
point-code 0.0.1
routing-indicator PC
hnb
iucs
remote-addr msc ! derives cs7 instance 1 and local pc 1.2.3
If 'point-code 1.2.3' is omitted, this becomes '0.0.0' without the user
noticing, and this happens for each client that omits it. I would like to barf
when no local PC is set.
Change-Id: I7f0f0c89b7335d9da24161bfac8234be214ca00c
Introduce OSMO_SS7_PC_INVALID to mark an unset point code.
Add static osmo_ss7_pc_is_valid() (name matches schema of
osmo_ss7_pc_is_local()).
In osmo_ss7_pointcode_print(), return "(no PC)" if !osmo_ss7_pc_is_valid(), for
convenient printing of any PC state.
Subsequent patches will use this for
osmo_ss7_instance (I7f0f0c89b7335d9da24161bfac8234be214ca00c)
as well as osmo_sccp_user (I8684c9b559712072c772012890bbf7efa7c8eb35).
Rationale:
Currently, in osmo_ss7_vty.c we had "if (inst->cfg.primary_pc)" suggesting 0 is
invalid, but in struct osmo_sccp_user we have flag pc_valid suggesting 0 is
indeed valid. All known point code formats are <= 24bit, so we can easily use
0xffffffff as indicator for an unset PC, which removes the need to remember to
set a second field for validity and keeps the structs nice and lean.
Change-Id: Ib5715bf03a4de7713a7a809dfd821c700255ba8c
The osmo_sccp_simple_client_on_ss7_id and osmo_sccp_simple_client
are not entirely configurable via VTY commands. The relation to
the VTY is implicit. The user may set up instance objects via
VTY (cs7/ss7, AS, ASP), which are then automatically created on
startup.
Each cs7 instance gets its own ID via the VTY configuration. When
osmo_sccp_simple_client_on_ss7_id() is called with the cs7 instance
id. (for osmo_sccp_simple_client() the ID will be hardcoded to 1),
the function automatically checks if the CS7 instance is present,
if not it will create one automatically using the caller supplied
parameters as a defult. If a CS7 instance is present, the function
checks for the presence of an AS and an ASP. These objects are
present, they will be used. If not, new objects will be created.
Both functions must not be called if an SCCP instance is already
present. Since there can only be one SCCP instance per CS7 instance,
this is an error condition.
Add additional logic that checks to detect an already existing, valid
configuration. If no or an insufficient configuration is detected,
use the caller supplied parameters as default configuration.
Change-Id: I293f3526ce6182dca74a169a23449dbc7af57c7c
Add function osmo_ss7_point_code_print2() to be able to print two point codes
in the same log message.
Change signatures of two static functions to aid logging:
add invalid ref arg to sccp_scoc_rx_inval_src_ref(),
pass conn instead of inst to sccp_scoc_rx_inval_opc().
Change-Id: Ia3243606d6cad7721f7da7f6caba2caa90ae2bbd
In osmo_ss7_route_create() as is only initalized if lset can not
be initalized. If lset can be initalized, as will not be used so
everything is fine. However, the compiler complains that as may
not be initalized. Initalizing as to NULL solves the problem.
Change-Id: Ibcb3ebf9aaa7717cb553242517abce1499bc9c2a
SCCP addresses are defined through a number of compoinents, not
just an IP-Address, there is also point code, ssn and more. To
simplify and unify the handling of such objects, this patch
introduces an addressbook functionality. The user can set up
multiple addresses per ss7 instance and give them names. Later
that name can be used to reference the address at a later point
in the config. This means that the usage of sccp-addresses from
the programmers point of view boils down to a VTY function that
reads the string name of a previously defined address. The
programmer can then use the API to get a pointer to the SCCP
address struct and use it normally.
For this feature, two additional VTY nodes are necessary,
this commit depends libosmocore change:
Change-Id I42aa29c0cccc97f284b85801c5329b015b189640
Change-Id: I068ed7f7d113dab88424a9d47bab7fc703bb7942
The 'user' argument to osmo_ss7_user_unregister() can be NULL, so let's
make sure we don't dereference it.
Change-Id: Ia34b181dcbcb179b2639e2f405364cc952069842
Fixes: coverity CID#166933
The use of m3ua_msgb_alloc() from generic code is a bit ugly, but I
really don't want to introduce yet another msgb_alloc wrapper.
Change-Id: Ic6dc9a1e7bbed2e1f73395bd18b727fa7892e25b
When we disconnect a client, make sure that we always go through
xua_cli_close_and_reconnect(), which will make sure to notify the ASP
FSM using XUA_ASP_E_SCTP_COMM_DOWN_IND.
Change-Id: I6859b8549c8cbbe2e8279da0ede562387a066d04
This tries as good as possible to fit the IPA/SCCPlite stacking into the
existing SIGTRAN/SS7 code architecture/model. To the user, the IPA
protocol looks like yet another protocol on the same level as the choice
between SUA and M3AU. On the inside, things are obviously quite
different.
We need to handle TCP with IPA framing instead of SCTP for both server
and client. We also implement an alternative "ASP FSM" for IPA, which
takes care of the CCM handshake (ID_REQ/ID_RESP/ID_ACK/ID_ACK2) for both
client and server mode.
In server mode, we use the 'unit name' as identifier to look up the AS,
similar to how we use a routing context to look up the AS in the xUA
case.
We also have to bypass activating the default layer manager in the
simple client to make sure we don't run into even more complexity.
What's missing right now is some way to manually override/set the point
codes. As IPA/SCCPlite is missing any routing label, we currently
simply generate one with SPC=0/DPC=0, which will obviously not work in
most configurations.
Change-Id: I9098574cddeba10fcf8f1b6c196a7069a6805c56
So when we create a xua_server for SUA, we must make sure to create that
associated SCCP instance, if it doesn't already exist. End-user
programs probably normally call this during their initialization anyway,
but in something like OsmoSTP, we need to auto-create it.
Change-Id: Ib575763dbd00f5bd7bfbf48f227a8f5ef9528e2a
Higher-layer code shouldn't have to worry between client and server
difference. It just wants to close the underlying connection for a
given ASP - which it now can by means of osmo_ss7_asp_disconnect().
Change-Id: I36b089abd281b8edac8830fda2d8e57cc06cd0a7
For classic xUA this is not needed, as the server doesn't have to react
to establishment of the SCTP connection. The client will start with an
ASP_UP_REQ. However, in upcoming IPA support, the FSM will need to
react on this event.
Change-Id: Ib10914b27f8761ea44a0fdba96c045821223722a
When dynamically allocating ASPs, we used the hardcoded M3UA protocol,
which is of course wrong in case of SUA or other protocols. Let's use
the xua_server's configured protocol for the created ASPs.
Change-Id: I07832cbaf1ca42f0c7df399e4f96599034b72816
When we destroy a xua_server, we would like to close and destroy any
ASPs that were established via that xua_server. In order to do so, we
need to add a list of ASPs to the xua_server, which we can iterate.
Change-Id: Iff3ed099b817e54e563b70d9ab40f63af63cc2fb
By moving this variable into the SS7 instance, we avoid one more global
variable, and we also fix a bug where the xua servers would be saved
multiple times (once per instance).
Change-Id: Icbab59d773f23cc8514cbeb6e21e25ca35dd337f
If we actually found an instance for the specified ID, return it fast
and don't (re)initialize all linked list heads, etc.
Change-Id: I91b6aabdb873ed8dd103918ee5e40b7ad3946735
This properly integrates the concept of multiple SS7 instances (each
with their own point code format, address indicator, ...) into the VTY.
At the same time, this also removes the stp-global "g_s7i" instance
that existed so far, moving the VTY code more into the direction of also
being able to be used outside the STP - which is underlined by splitting
the vty commands between those generally useful, and those useful only
for a STP or only for a simpla ASP (client).
Change-Id: I30966fbf2e143318cd9127eb8c17cccb24407106
When RKM dynamically allocates ASs on the SGP based on RKM registration
requests, we must make sure to properly destroy those at the time the
related ASP disconnects. Also, make sure to send
XUA_ASP_E_SCTP_COMM_DOWN_IND to the layer manager (if any).
Change-Id: Ie6505680bb6890814ae36858c54a2a6d2850f5cf
This "default layer manager" can optionally be used by a xUA ASP. It
will handle the xUA Layer Manager (xlm) primitives and use them to
behave as follows:
* bring the ASP into state "INACTIVE"
* see if the SG can match our connection (based on IP address + port
information) to a statically configured ASP configuration with
associated AS(s). If yes, it will send us a NOTIFY message with
AS-INACTIVE.
* if the above doesn't work, try to dynamically register a routing key
using RKM for the point code that was locally confiured on the
ASP/client. If that works, the SG will now have created ASP and AS
objects as well as a routing key and be able to serve us, sending the
NOTIFY with the AS-INACTIVE state.
* After either of the two above, we will attempt to transition into
ASP-ACTIVE. The SG should send us an AS-ACTIVE notification in return
* if anything fails, abort and disconnect the SCTP connection, restart
related FSMs and start from scratch
Change-Id: I78d4623dd213b5c59007a026a6cc3cfe5c04af50
osmo-stp is able to define multiple M3UA and/or SUA application servers
(AS) as well as application server processes (ASPs). Clients can then
connect via M3UA or SUA, perform the respective ASPSM / ASPTM state
changes and finally exchange MTP signaling such as ISUP or SCCP on top
of it. Routing is currently only based on point codes (PC). Routing table
is fully configurable with Destination PC and mask.
Shortcomings:
* xUA: only "override" traffic mode supported, no load-balance or broadcast
* xUA: no SNM supported, i.e. DAVA/DUNA/... messages are neither parsed
nor generated
* SCCP: no Global Title based Routing (GTR) yet
* SCCP: no Global Title Translation (GTT) yet
* no M2PA / M2UA sigtran dialects
* no classic CS7 based signaling links(E1/T1 TDM)
Change-Id: If32227b8d3127c6178e4ee45527ce65f69bc7b1e
In 17df5953ff we fixed endianness issues
with the Stream ID field, but at the same time mistook the PPID field
for 16bits. In reality it is 32bits, and hence our 'htons' is rendering
wrong PPID values.
Change-Id: Ief04486e752e6b7e0a853b1fa9ca525ad47800f6