extcap: fix management of multicheck and saved non boolean arguments
Launching USBPcap without going in the interface options menu exhibits 2 bugs: - we should restore a value only if it is not an empty string (otherwise USBPcap with an ampty --devices multicheck argument) - when building the argument list for a non boolean argument not using the default value, do not call g_strconcat. It will build a string concatenating the option and value (for example "--devices 1" that will be treated as a single argument). Instead option and value must be given separately to argument list. Bug: 12846 Change-Id: I5628cb264a7632089e6579e9ae7400e2c0e500e2 Reviewed-on: https://code.wireshark.org/review/17773 Reviewed-by: Pascal Quantin <pascal.quantin@gmail.com> Petri-Dish: Pascal Quantin <pascal.quantin@gmail.com> Tested-by: Petri Dish Buildbot <buildbot-no-reply@wireshark.org> Reviewed-by: Roland Knall <rknall@gmail.com>
This commit is contained in:
parent
a978ad7ce3
commit
66203b4f31
7
extcap.c
7
extcap.c
|
@ -618,7 +618,7 @@ static gboolean search_cb(const gchar *extcap _U_, const gchar *ifname _U_, gcha
|
|||
pref_title, pref_title, (const char **)arg->pref_valptr);
|
||||
} else {
|
||||
/* Been here before, restore stored value */
|
||||
if (! arg->pref_valptr && pref->varp.string)
|
||||
if (! arg->pref_valptr && pref->varp.string && strlen(*pref->varp.string))
|
||||
{
|
||||
arg->pref_valptr = pref->varp.string;
|
||||
}
|
||||
|
@ -1010,9 +1010,8 @@ GPtrArray * extcap_prepare_arguments(interface_options interface_opts)
|
|||
if ( g_strcmp0(stored, "true") == 0 )
|
||||
add_arg(arg_iter->call);
|
||||
} else {
|
||||
gchar * call = g_strconcat(arg_iter->call, " ", stored, NULL);
|
||||
add_arg(call);
|
||||
g_free(call);
|
||||
add_arg(arg_iter->call);
|
||||
add_arg(stored);
|
||||
}
|
||||
} else if (arg_iter->arg_type == EXTCAP_ARG_BOOLFLAG) {
|
||||
if (extcap_complex_get_bool(arg_iter->default_complex))
|
||||
|
|