* @author ETSI / STF519
|
|
* @version $URL$
|
|
* $Id$
|
|
* @desc This module provides the PICS used for the S1AP tests.
|
|
* @copyright ETSI Copyright Notification
|
|
* No part may be reproduced except as authorized by written permission.
|
|
* The copyright and the foregoing restriction extend to reproduction in all media.
|
|
* All rights reserved.
|
|
* @see ETSI TS 136 413 / 3GPP TS 36.413 version 13.4.0 Release 13
|
|
*/
|
|
module S1AP_Pics {
|
|
|
|
group PICS_A2 {
|
|
/**
|
|
* @desc Does eNB act as the IUT?
|
|
* @see ETSI DTS_INT-00135-1 A.2/1
|
|
*/
|
|
modulepar boolean PICS_S1AP_eNB_IUT := false;
|
|
|
|
/**
|
|
* @desc Does MME act as the IUT?
|
|
* @see ETSI DTS_INT-00135-1 A.2/2
|
|
*/
|
|
modulepar boolean PICS_S1AP_MME_IUT := false;
|
|
|
|
} // End of group PICS_A2
|
|
|
|
group PICS_A3 {
|
|
|
|
/**
|
|
* @desc Does eNB support repetition of the sending of eNB CONFIGURATION UPDATE messages in case of no reply?
|
|
* @see ETSI DTS_INT-00135-1 A.3/6.4.1
|
|
*/
|
|
modulepar boolean PICS_S1AP_eNB_REPETITION_SENDING_CONF_UPDATE := false;
|
|
|
|
/**
|
|
* @desc Does eNB support initiation oft the Error Indication procedure when a transfer syntax error is detected?
|
|
* @see ETSI DTS_INT-00135-1 A.3/17.1
|
|
*/
|
|
modulepar boolean PICS_S1AP_eNB_INITIATION_ERROR_IND_PROCEDURE := false;
|
|
|
|
/**
|
|
* @desc Does eNB support initiation of the Error Indication procedure when an abstract syntax error is detected?
|
|
* @see ETSI DTS_INT-00135-1 A.3/17.2
|
|
*/
|
|
modulepar boolean PICS_S1AP_eNB_INITIATION_ERROR_IND_ABSTRACT_SYNTAX_PROCEDURE := false;
|
|
|
|
/**
|
|
* @desc Does eNB support initiation of the Error Indication procedure when a logical error is detected?
|
|
* @see ETSI DTS_INT-00135-1 A.3/17.3
|
|
*/
|
|
modulepar boolean PICS_S1AP_eNB_INITIATION_ERROR_IND_LOGICAL_ERROR_PROCEDURE := false;
|
|
|
|
} // End of group PICS_A3
|
|
|
|
group PICS_A4 {
|
|
|
|
/**
|
|
* @desc Does eNB support initiation oft the Error Indication procedure when a transfer syntax error is detected?
|
|
* @see ETSI DTS_INT-00135-1 A.4/17.1
|
|
*/
|
|
modulepar boolean PICS_S1AP_MME_INITIATION_ERROR_IND_PROCEDURE := false;
|
|
|
|
/**
|
|
* @desc Does eNB support initiation of the Error Indication procedure when an abstract syntax error is detected?
|
|
* @see ETSI DTS_INT-00135-1 A.4/17.2
|
|
*/
|
|
modulepar boolean PICS_S1AP_MME_INITIATION_ERROR_IND_ABSTRACT_SYNTAX_PROCEDURE := false;
|
|
|
|
/**
|
|
* @desc Does eNB support initiation of the Error Indication procedure when a logical error is detected?
|
|
* @see ETSI DTS_INT-00135-1 A.4/17.3
|
|
*/
|
|
modulepar boolean PICS_S1AP_MME_INITIATION_ERROR_IND_LOGICAL_ERROR_PROCEDURE := false;
|
|
|
|
} // End of group PICS_A4
|
|
|
|
} // End of module S1AP_Pics
|