dect
/
linux-2.6
Archived
13
0
Fork 0

e1000e: link up/down messages must follow a specific format

The system log messages created on a link status change need to follow a
specific format to work with tools some customers use.

Signed-off-by: Bruce Allan <bruce.w.allan@intel.com>
Signed-off-by: Jeff Kirsher <jeffrey.t.kirsher@intel.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
This commit is contained in:
Bruce Allan 2008-11-21 16:54:43 -08:00 committed by David S. Miller
parent 75eb0fad56
commit 8f12fe8653
1 changed files with 7 additions and 2 deletions

View File

@ -3408,7 +3408,10 @@ static void e1000_print_link_info(struct e1000_adapter *adapter)
struct e1000_hw *hw = &adapter->hw;
u32 ctrl = er32(CTRL);
e_info("Link is Up %d Mbps %s, Flow Control: %s\n",
/* Link status message must follow this format for user tools */
printk(KERN_INFO "e1000e: %s NIC Link is Up %d Mbps %s, "
"Flow Control: %s\n",
adapter->netdev->name,
adapter->link_speed,
(adapter->link_duplex == FULL_DUPLEX) ?
"Full Duplex" : "Half Duplex",
@ -3618,7 +3621,9 @@ static void e1000_watchdog_task(struct work_struct *work)
if (netif_carrier_ok(netdev)) {
adapter->link_speed = 0;
adapter->link_duplex = 0;
e_info("Link is Down\n");
/* Link status message must follow this format */
printk(KERN_INFO "e1000e: %s NIC Link is Down\n",
adapter->netdev->name);
netif_carrier_off(netdev);
netif_tx_stop_all_queues(netdev);
if (!test_bit(__E1000_DOWN, &adapter->state))