From 81e403ce3c6a34cd705bf54d4cdeefdeb7068a8d Mon Sep 17 00:00:00 2001 From: "Yang, Bo" Date: Tue, 6 Oct 2009 14:27:54 -0600 Subject: [PATCH] [SCSI] megaraid_sas: infrastructure to get PDs from FW Add system PDs to OS. Driver implemented the get_pd_list function to get the system PD from FW. Signed-off-by Bo Yang Signed-off-by: James Bottomley --- drivers/scsi/megaraid/megaraid_sas.c | 96 ++++++++++++++++++++++++++++ drivers/scsi/megaraid/megaraid_sas.h | 90 +++++++++++++++++++++++++- 2 files changed, 183 insertions(+), 3 deletions(-) diff --git a/drivers/scsi/megaraid/megaraid_sas.c b/drivers/scsi/megaraid/megaraid_sas.c index b6e43271883..48c3658d73a 100644 --- a/drivers/scsi/megaraid/megaraid_sas.c +++ b/drivers/scsi/megaraid/megaraid_sas.c @@ -2036,6 +2036,98 @@ static int megasas_alloc_cmds(struct megasas_instance *instance) return 0; } +/* + * megasas_get_pd_list_info - Returns FW's pd_list structure + * @instance: Adapter soft state + * @pd_list: pd_list structure + * + * Issues an internal command (DCMD) to get the FW's controller PD + * list structure. This information is mainly used to find out SYSTEM + * supported by the FW. + */ +static int +megasas_get_pd_list(struct megasas_instance *instance) +{ + int ret = 0, pd_index = 0; + struct megasas_cmd *cmd; + struct megasas_dcmd_frame *dcmd; + struct MR_PD_LIST *ci; + struct MR_PD_ADDRESS *pd_addr; + dma_addr_t ci_h = 0; + + cmd = megasas_get_cmd(instance); + + if (!cmd) { + printk(KERN_DEBUG "megasas (get_pd_list): Failed to get cmd\n"); + return -ENOMEM; + } + + dcmd = &cmd->frame->dcmd; + + ci = pci_alloc_consistent(instance->pdev, + MEGASAS_MAX_PD * sizeof(struct MR_PD_LIST), &ci_h); + + if (!ci) { + printk(KERN_DEBUG "Failed to alloc mem for pd_list\n"); + megasas_return_cmd(instance, cmd); + return -ENOMEM; + } + + memset(ci, 0, sizeof(*ci)); + memset(dcmd->mbox.b, 0, MFI_MBOX_SIZE); + + dcmd->mbox.b[0] = MR_PD_QUERY_TYPE_EXPOSED_TO_HOST; + dcmd->mbox.b[1] = 0; + dcmd->cmd = MFI_CMD_DCMD; + dcmd->cmd_status = 0xFF; + dcmd->sge_count = 1; + dcmd->flags = MFI_FRAME_DIR_READ; + dcmd->timeout = 0; + dcmd->data_xfer_len = MEGASAS_MAX_PD * sizeof(struct MR_PD_LIST); + dcmd->opcode = MR_DCMD_PD_LIST_QUERY; + dcmd->sgl.sge32[0].phys_addr = ci_h; + dcmd->sgl.sge32[0].length = MEGASAS_MAX_PD * sizeof(struct MR_PD_LIST); + + if (!megasas_issue_polled(instance, cmd)) { + ret = 0; + } else { + ret = -1; + } + + /* + * the following function will get the instance PD LIST. + */ + + pd_addr = ci->addr; + + if ( ret == 0 && + (ci->count < + (MEGASAS_MAX_PD_CHANNELS * MEGASAS_MAX_DEV_PER_CHANNEL))) { + + memset(instance->pd_list, 0, + MEGASAS_MAX_PD * sizeof(struct megasas_pd_list)); + + for (pd_index = 0; pd_index < ci->count; pd_index++) { + + instance->pd_list[pd_addr->deviceId].tid = + pd_addr->deviceId; + instance->pd_list[pd_addr->deviceId].driveType = + pd_addr->scsiDevType; + instance->pd_list[pd_addr->deviceId].driveState = + MR_PD_STATE_SYSTEM; + pd_addr++; + } + } + + pci_free_consistent(instance->pdev, + MEGASAS_MAX_PD * sizeof(struct MR_PD_LIST), + ci, ci_h); + megasas_return_cmd(instance, cmd); + + return ret; +} + + /** * megasas_get_controller_info - Returns FW's controller structure * @instance: Adapter soft state @@ -2326,6 +2418,10 @@ static int megasas_init_mfi(struct megasas_instance *instance) if (megasas_issue_init_mfi(instance)) goto fail_fw_init; + memset(instance->pd_list, 0 , + (MEGASAS_MAX_PD * sizeof(struct megasas_pd_list))); + megasas_get_pd_list(instance); + ctrl_info = kmalloc(sizeof(struct megasas_ctrl_info), GFP_KERNEL); /* diff --git a/drivers/scsi/megaraid/megaraid_sas.h b/drivers/scsi/megaraid/megaraid_sas.h index 365a9617207..8ac6b2659c1 100644 --- a/drivers/scsi/megaraid/megaraid_sas.h +++ b/drivers/scsi/megaraid/megaraid_sas.h @@ -133,6 +133,7 @@ #define MR_DCMD_CLUSTER 0x08000000 #define MR_DCMD_CLUSTER_RESET_ALL 0x08010100 #define MR_DCMD_CLUSTER_RESET_LD 0x08010200 +#define MR_DCMD_PD_LIST_QUERY 0x02010100 /* * MFI command completion codes @@ -253,9 +254,89 @@ enum MR_EVT_ARGS { MR_EVT_ARGS_STR, MR_EVT_ARGS_TIME, MR_EVT_ARGS_ECC, - + MR_EVT_ARGS_LD_PROP, + MR_EVT_ARGS_PD_SPARE, + MR_EVT_ARGS_PD_INDEX, + MR_EVT_ARGS_DIAG_PASS, + MR_EVT_ARGS_DIAG_FAIL, + MR_EVT_ARGS_PD_LBA_LBA, + MR_EVT_ARGS_PORT_PHY, + MR_EVT_ARGS_PD_MISSING, + MR_EVT_ARGS_PD_ADDRESS, + MR_EVT_ARGS_BITMAP, + MR_EVT_ARGS_CONNECTOR, + MR_EVT_ARGS_PD_PD, + MR_EVT_ARGS_PD_FRU, + MR_EVT_ARGS_PD_PATHINFO, + MR_EVT_ARGS_PD_POWER_STATE, + MR_EVT_ARGS_GENERIC, }; +/* + * define constants for device list query options + */ +enum MR_PD_QUERY_TYPE { + MR_PD_QUERY_TYPE_ALL = 0, + MR_PD_QUERY_TYPE_STATE = 1, + MR_PD_QUERY_TYPE_POWER_STATE = 2, + MR_PD_QUERY_TYPE_MEDIA_TYPE = 3, + MR_PD_QUERY_TYPE_SPEED = 4, + MR_PD_QUERY_TYPE_EXPOSED_TO_HOST = 5, +}; + +enum MR_PD_STATE { + MR_PD_STATE_UNCONFIGURED_GOOD = 0x00, + MR_PD_STATE_UNCONFIGURED_BAD = 0x01, + MR_PD_STATE_HOT_SPARE = 0x02, + MR_PD_STATE_OFFLINE = 0x10, + MR_PD_STATE_FAILED = 0x11, + MR_PD_STATE_REBUILD = 0x14, + MR_PD_STATE_ONLINE = 0x18, + MR_PD_STATE_COPYBACK = 0x20, + MR_PD_STATE_SYSTEM = 0x40, + }; + + + /* + * defines the physical drive address structure + */ +struct MR_PD_ADDRESS { + u16 deviceId; + u16 enclDeviceId; + + union { + struct { + u8 enclIndex; + u8 slotNumber; + } mrPdAddress; + struct { + u8 enclPosition; + u8 enclConnectorIndex; + } mrEnclAddress; + }; + u8 scsiDevType; + union { + u8 connectedPortBitmap; + u8 connectedPortNumbers; + }; + u64 sasAddr[2]; +} __packed; + +/* + * defines the physical drive list structure + */ +struct MR_PD_LIST { + u32 size; + u32 count; + struct MR_PD_ADDRESS addr[1]; +} __packed; + +struct megasas_pd_list { + u16 tid; + u8 driveType; + u8 driveState; +} __packed; + /* * SAS controller properties */ @@ -284,7 +365,7 @@ struct megasas_ctrl_prop { u8 expose_encl_devices; u8 reserved[38]; -} __attribute__ ((packed)); +} __packed; /* * SAS controller information @@ -527,7 +608,7 @@ struct megasas_ctrl_info { u8 pad[0x800 - 0x6a0]; -} __attribute__ ((packed)); +} __packed; /* * =============================== @@ -542,6 +623,8 @@ struct megasas_ctrl_info { #define MEGASAS_DEFAULT_INIT_ID -1 #define MEGASAS_MAX_LUN 8 #define MEGASAS_MAX_LD 64 +#define MEGASAS_MAX_PD (MEGASAS_MAX_PD_CHANNELS * \ + MEGASAS_MAX_DEV_PER_CHANNEL) #define MEGASAS_DBG_LVL 1 @@ -1089,6 +1172,7 @@ struct megasas_instance { unsigned long base_addr; struct megasas_register_set __iomem *reg_set; + struct megasas_pd_list pd_list[MEGASAS_MAX_PD]; s8 init_id; u16 max_num_sge;