Bluetooth: Don't use cmd_timer to timeout HCI reset command

No command should be send before Command Complete event for HCI
reset is received. This fix regression introduced by commit
6bd32326cda(Bluetooth: Use proper timer for hci command timout)
for chips whose reset command takes longer to complete (e.g. CSR)
resulting in next command being send before HCI reset completed.

Signed-off-by: Szymon Janc <szymon@janc.net.pl>
Signed-off-by: Gustavo F. Padovan <padovan@profusion.mobi>
This commit is contained in:
Szymon Janc 2011-07-26 22:46:54 +02:00 committed by Gustavo F. Padovan
parent 6be6b11f00
commit 7bdb8a5cf1
1 changed files with 4 additions and 2 deletions

View File

@ -1209,7 +1209,6 @@ static void hci_cmd_timer(unsigned long arg)
BT_ERR("%s command tx timeout", hdev->name);
atomic_set(&hdev->cmd_cnt, 1);
clear_bit(HCI_RESET, &hdev->flags);
tasklet_schedule(&hdev->cmd_task);
}
@ -2408,7 +2407,10 @@ static void hci_cmd_task(unsigned long arg)
if (hdev->sent_cmd) {
atomic_dec(&hdev->cmd_cnt);
hci_send_frame(skb);
mod_timer(&hdev->cmd_timer,
if (test_bit(HCI_RESET, &hdev->flags))
del_timer(&hdev->cmd_timer);
else
mod_timer(&hdev->cmd_timer,
jiffies + msecs_to_jiffies(HCI_CMD_TIMEOUT));
} else {
skb_queue_head(&hdev->cmd_q, skb);