ACPI: thinkpad-acpi: make EC-based thermal readings non-experimental

Reading the 16 thermal sensors directly from the EC has been stable for
about one year, in all supported ThinkPad models.  Remove its
"experimental" label.

Signed-off-by: Henrique de Moraes Holschuh <hmh@hmh.eng.br>
Signed-off-by: Len Brown <len.brown@intel.com>
This commit is contained in:
Henrique de Moraes Holschuh 2007-07-18 23:45:46 -03:00 committed by Len Brown
parent a8fba3da3d
commit 3d6f99ca00
2 changed files with 6 additions and 14 deletions

View File

@ -710,23 +710,15 @@ Temperature sensors
procfs: /proc/acpi/ibm/thermal
sysfs device attributes: (hwmon) temp*_input
Most ThinkPads include six or more separate temperature sensors but
only expose the CPU temperature through the standard ACPI methods.
This feature shows readings from up to eight different sensors on older
ThinkPads, and it has experimental support for up to sixteen different
sensors on newer ThinkPads.
EXPERIMENTAL: The 16-sensors feature is marked EXPERIMENTAL because the
implementation directly accesses hardware registers and may not work as
expected. USE WITH CAUTION! To use this feature, you need to supply the
experimental=1 parameter when loading the module. When EXPERIMENTAL
mode is enabled, reading the first 8 sensors on newer ThinkPads will
also use an new experimental thermal sensor access mode.
Most ThinkPads include six or more separate temperature sensors but only
expose the CPU temperature through the standard ACPI methods. This
feature shows readings from up to eight different sensors on older
ThinkPads, and up to sixteen different sensors on newer ThinkPads.
For example, on the X40, a typical output may be:
temperatures: 42 42 45 41 36 -128 33 -128
EXPERIMENTAL: On the T43/p, a typical output may be:
On the T43/p, a typical output may be:
temperatures: 48 48 36 52 38 -128 31 -128 48 52 48 -128 -128 -128 -128 -128
The mapping of thermal sensors to physical locations varies depending on

View File

@ -2709,7 +2709,7 @@ static int __init thermal_init(struct ibm_init_struct *iibm)
acpi_tmp7 = acpi_evalf(ec_handle, NULL, "TMP7", "qv");
if (thinkpad_id.ec_model && experimental) {
if (thinkpad_id.ec_model) {
/*
* Direct EC access mode: sensors at registers
* 0x78-0x7F, 0xC0-0xC7. Registers return 0x00 for