diff --git a/drivers/power/charger-manager.c b/drivers/power/charger-manager.c index cdf29d2eb7a..c701f5e6f32 100644 --- a/drivers/power/charger-manager.c +++ b/drivers/power/charger-manager.c @@ -226,6 +226,58 @@ static bool is_charging(struct charger_manager *cm) return charging; } +/** + * is_full_charged - Returns true if the battery is fully charged. + * @cm: the Charger Manager representing the battery. + */ +static bool is_full_charged(struct charger_manager *cm) +{ + struct charger_desc *desc = cm->desc; + union power_supply_propval val; + int ret = 0; + int uV; + + /* If there is no battery, it cannot be charged */ + if (!is_batt_present(cm)) { + val.intval = 0; + goto out; + } + + if (cm->fuel_gauge && desc->fullbatt_full_capacity > 0) { + /* Not full if capacity of fuel gauge isn't full */ + ret = cm->fuel_gauge->get_property(cm->fuel_gauge, + POWER_SUPPLY_PROP_CHARGE_FULL, &val); + if (!ret && val.intval > desc->fullbatt_full_capacity) { + val.intval = 1; + goto out; + } + } + + /* Full, if it's over the fullbatt voltage */ + if (desc->fullbatt_uV > 0) { + ret = get_batt_uV(cm, &uV); + if (!ret && uV >= desc->fullbatt_uV) { + val.intval = 1; + goto out; + } + } + + /* Full, if the capacity is more than fullbatt_soc */ + if (cm->fuel_gauge && desc->fullbatt_soc > 0) { + ret = cm->fuel_gauge->get_property(cm->fuel_gauge, + POWER_SUPPLY_PROP_CAPACITY, &val); + if (!ret && val.intval >= desc->fullbatt_soc) { + val.intval = 1; + goto out; + } + } + + val.intval = 0; + +out: + return val.intval ? true : false; +} + /** * is_polling_required - Return true if need to continue polling for this CM. * @cm: the Charger Manager representing the battery. @@ -418,7 +470,7 @@ static void fullbatt_vchk(struct work_struct *work) diff = desc->fullbatt_uV; diff -= batt_uV; - dev_dbg(cm->dev, "VBATT dropped %duV after full-batt.\n", diff); + dev_info(cm->dev, "VBATT dropped %duV after full-batt.\n", diff); if (diff > desc->fullbatt_vchkdrop_uV) { try_charger_restart(cm); @@ -441,10 +493,14 @@ static bool _cm_monitor(struct charger_manager *cm) dev_dbg(cm->dev, "monitoring (%2.2d.%3.3dC)\n", cm->last_temp_mC / 1000, cm->last_temp_mC % 1000); - /* It has been stopped or charging already */ - if (!!temp == !!cm->emergency_stop) + /* It has been stopped already */ + if (temp && cm->emergency_stop) return false; + /* + * Check temperature whether overheat or cold. + * If temperature is out of range normal state, stop charging. + */ if (temp) { cm->emergency_stop = temp; if (!try_charger_enable(cm, false)) { @@ -453,10 +509,34 @@ static bool _cm_monitor(struct charger_manager *cm) else uevent_notify(cm, "COLD"); } + + /* + * Check dropped voltage of battery. If battery voltage is more + * dropped than fullbatt_vchkdrop_uV after fully charged state, + * charger-manager have to recharge battery. + */ + } else if (!cm->emergency_stop && is_ext_pwr_online(cm) && + !cm->charger_enabled) { + fullbatt_vchk(&cm->fullbatt_vchk_work.work); + + /* + * Check whether fully charged state to protect overcharge + * if charger-manager is charging for battery. + */ + } else if (!cm->emergency_stop && is_full_charged(cm) && + cm->charger_enabled) { + dev_info(cm->dev, "EVENT_HANDLE: Battery Fully Charged.\n"); + uevent_notify(cm, default_event_names[CM_EVENT_BATT_FULL]); + + try_charger_enable(cm, false); + + fullbatt_vchk(&cm->fullbatt_vchk_work.work); } else { cm->emergency_stop = 0; - if (!try_charger_enable(cm, true)) - uevent_notify(cm, "CHARGING"); + if (is_ext_pwr_online(cm)) { + if (!try_charger_enable(cm, true)) + uevent_notify(cm, "CHARGING"); + } } return true; @@ -719,47 +799,10 @@ static int charger_get_property(struct power_supply *psy, val->intval = 0; break; case POWER_SUPPLY_PROP_CHARGE_FULL: - if (cm->fuel_gauge) { - if (cm->fuel_gauge->get_property(cm->fuel_gauge, - POWER_SUPPLY_PROP_CHARGE_FULL, val) == 0) - break; - } - - if (is_ext_pwr_online(cm)) { - /* Not full if it's charging. */ - if (is_charging(cm)) { - val->intval = 0; - break; - } - /* - * Full if it's powered but not charging andi - * not forced stop by emergency - */ - if (!cm->emergency_stop) { - val->intval = 1; - break; - } - } - - /* Full if it's over the fullbatt voltage */ - ret = get_batt_uV(cm, &uV); - if (!ret && desc->fullbatt_uV > 0 && uV >= desc->fullbatt_uV && - !is_charging(cm)) { + if (is_full_charged(cm)) val->intval = 1; - break; - } - - /* Full if the cap is 100 */ - if (cm->fuel_gauge) { - ret = cm->fuel_gauge->get_property(cm->fuel_gauge, - POWER_SUPPLY_PROP_CAPACITY, val); - if (!ret && val->intval >= 100 && !is_charging(cm)) { - val->intval = 1; - break; - } - } - - val->intval = 0; + else + val->intval = 0; ret = 0; break; case POWER_SUPPLY_PROP_CHARGE_NOW: @@ -1049,7 +1092,26 @@ static int charger_extcon_notifier(struct notifier_block *self, struct charger_cable *cable = container_of(self, struct charger_cable, nb); + /* + * The newly state of charger cable. + * If cable is attached, cable->attached is true. + */ cable->attached = event; + + /* + * Setup monitoring to check battery state + * when charger cable is attached. + */ + if (cable->attached && is_polling_required(cable->cm)) { + if (work_pending(&setup_polling)) + cancel_work_sync(&setup_polling); + schedule_work(&setup_polling); + } + + /* + * Setup work for controlling charger(regulator) + * according to charger cable. + */ schedule_work(&cable->wq); return NOTIFY_DONE; @@ -1143,6 +1205,15 @@ static int charger_manager_probe(struct platform_device *pdev) desc->fullbatt_vchkdrop_ms = 0; desc->fullbatt_vchkdrop_uV = 0; } + if (desc->fullbatt_soc == 0) { + dev_info(&pdev->dev, "Ignoring full-battery soc(state of" + " charge) threshold as it is not" + " supplied."); + } + if (desc->fullbatt_full_capacity == 0) { + dev_info(&pdev->dev, "Ignoring full-battery full capacity" + " threshold as it is not supplied."); + } if (!desc->charger_regulators || desc->num_charger_regulators < 1) { ret = -EINVAL; diff --git a/include/linux/power/charger-manager.h b/include/linux/power/charger-manager.h index b542270affc..76b37ef3c07 100644 --- a/include/linux/power/charger-manager.h +++ b/include/linux/power/charger-manager.h @@ -140,7 +140,11 @@ struct charger_regulator { * If it has dropped more than fullbatt_vchkdrop_uV after * fullbatt_vchkdrop_ms, CM will restart charging. * @fullbatt_uV: voltage in microvolt - * If it is not being charged and VBATT >= fullbatt_uV, + * If VBATT >= fullbatt_uV, it is assumed to be full. + * @fullbatt_soc: state of Charge in % + * If state of Charge >= fullbatt_soc, it is assumed to be full. + * @fullbatt_full_capacity: full capacity measure + * If full capacity of battery >= fullbatt_full_capacity, * it is assumed to be full. * @polling_interval_ms: interval in millisecond at which * charger manager will monitor battery health @@ -168,6 +172,8 @@ struct charger_desc { unsigned int fullbatt_vchkdrop_ms; unsigned int fullbatt_vchkdrop_uV; unsigned int fullbatt_uV; + unsigned int fullbatt_soc; + unsigned int fullbatt_full_capacity; enum data_source battery_present;