LMSDevice: Call LMS_Init() before setting sample rate

LMS_Init() will override basically all device settings with their
default value, including the sample rate.  We hence have to make sure
to call it before any other API function that changes the device config
such as sample rate, frequency, filter bandwidth, ...

Change-Id: I4cdbae8406b5e1e93da491e90f8bad41d4be748b
This commit is contained in:
Harald Welte 2018-04-28 21:38:58 +02:00
parent c38e45e9dc
commit 9cb4f27112
1 changed files with 6 additions and 4 deletions

View File

@ -112,6 +112,12 @@ int LMSDevice::open(const std::string &args, int ref, bool swap_channels)
delete [] info_list;
LOG(INFO) << "Init LMS device";
if (LMS_Init(m_lms_dev) != 0) {
LOG(ERROR) << "LMS_Init() failed";
return -1;
}
LOG(DEBUG) << "Setting sample rate to " << GSMRATE*sps << " " << sps;
if (LMS_SetSampleRate(m_lms_dev, GSMRATE*sps, 32) < 0)
goto out_close;
@ -139,10 +145,6 @@ int LMSDevice::open(const std::string &args, int ref, bool swap_channels)
goto out_close;
}
LOG(INFO) << "Init LMS device";
if (LMS_Init(m_lms_dev) < 0)
goto out_close;
/* Perform Rx and Tx calibration */
for (i=0; i<chans; i++) {
LOG(INFO) << "Calibrating chan " << i;