MNCC<->SIP bridge; attaches to OsmoMSC to interface with external SIP VoIP telephony https://osmocom.org/projects/osmo-sip-conector
Go to file
Oliver Smith 8a6754597a Fix DISTCHECK_CONFIGURE_FLAGS override
Set AM_DISTCHECK_CONFIGURE_FLAGS in Makefile.am instead of
DISTCHECK_CONFIGURE_FLAGS. This is the recommended way from the
automake manual, as otherwise the flag can't be changed by the user
anymore.

Related: OS#3718
Change-Id: I6aadee1ab05b4caec0857e476190db7b83c85984
2018-12-04 15:32:11 +01:00
contrib Install systemd services with autotools 2018-09-10 16:09:56 +02:00
debian Install sample cfg file to /etc/osmocom 2018-09-12 20:29:17 +02:00
doc build manuals moved here from osmo-gsm-manuals.git 2018-11-27 18:34:56 +01:00
src Allow GSM340_PLAN_UNKNOWN on MNCC originated leg. 2018-11-12 17:07:06 +01:00
tests distcheck/tests: Add the referenced osmoappdesc.py for testing 2016-04-24 22:28:35 +02:00
.gitignore build manuals moved here from osmo-gsm-manuals.git 2018-11-27 18:34:56 +01:00
.gitreview Add git review config 2017-08-25 18:38:05 +02:00
COPYING Initial commit for a MNCC to SIP gateway (and maybe auth GW too) 2016-03-21 09:54:37 +01:00
Makefile.am Fix DISTCHECK_CONFIGURE_FLAGS override 2018-12-04 15:32:11 +01:00
README.asciidoc Write down some of the limitations of the current setup 2016-03-26 16:31:00 +01:00
configure.ac build manuals moved here from osmo-gsm-manuals.git 2018-11-27 18:34:56 +01:00
git-version-gen Fix git-version-gen 2017-10-28 18:20:00 +02:00
osmoappdesc.py osmoappdesc: Fix VTY prompt to use OsmoSIPcon, not old OsmoMNCC 2018-03-27 15:51:02 +02:00

README.asciidoc

Osmo SIP Connector
==================

Simple utility to map MNCC to SIP and SIP to MNCC. The VTY interface
can be used to make configurations. The code doesn't have any RTP or
transcoding support.

Call identities can be either the MSISDN or the IMSI of the subscriber.


Requirements of Equipment
^^^^^^^^^^^^^^^^^^^^^^^^^

* DTMF need to be sent using SIP INFO messages. DTMF in RTP is not
supported.

* BTS+PBX and SIP connector+PBX  must be in the same network (UDP must be
able to flow directly between these elements)

* No handover support.

* IP based BTS (e.g. Sysmocom sysmoBTS but no Siemens BS11)

* No emergency calls

Limitations
^^^^^^^^^^^

* PT of RTP needs to match the one used by the BTS. E.g. AMR needs to use
the same PT as the BTS. This is because rtp_payload2 is not yet supported
by the osmo-bts software.

* AMR SDP file doesn't include the mode-set params and allowed codec modes.
This needs to be configured in some way.