OsmoSIPConnector: fix: avoid OsmoMGW/OsmoSIPcon confusion

Change-Id: If20700d94775e91f174a1a07e00820ef0a91cd2f
This commit is contained in:
Vadim Yanitskiy 2018-08-30 01:35:44 +07:00 committed by Neels Hofmeyr
parent a3a28acaa1
commit 2e331aed4e
1 changed files with 7 additions and 7 deletions

View File

@ -16,8 +16,8 @@ line `osmo-msc -M /tmp/msc_mncc`.
.Example: MNCC configuration
----
OsmoMGW(config)# mncc
OsmoMGW(config-mncc)# socket-path /tmp/msc_mncc
OsmoSIPcon(config)# mncc
OsmoSIPcon(config-mncc)# socket-path /tmp/msc_mncc
----
=== Configuring SIP
@ -27,9 +27,9 @@ can be set for the connection to the PBX.
.Example: SIP configuration
----
OsmoMGW(config)# sip
OsmoMGW(config-sip)# local 10.0.0.1 5060 <1>
OsmoMGW(config-sip)# remote 10.0.0.2 5060 <2>
OsmoSIPcon(config)# sip
OsmoSIPcon(config-sip)# local 10.0.0.1 5060 <1>
OsmoSIPcon(config-sip)# remote 10.0.0.2 5060 <2>
----
<1> The local IP/port to use
<2> The remote SIP IP/port that the PBX uses
@ -39,8 +39,8 @@ MO- and as called (destination) address for MT-calls.
.Example: Use IMSI instead of MSISDN
----
OsmoMGW(config)# app
OsmoMGW(config-app)# use-imsi <1>
OsmoSIPcon(config)# app
OsmoSIPcon(config-app)# use-imsi <1>
----
<1> Use the IMSI for MO calling and MT called address