It may happen that either the MS or an ESME would become
unresponsive, e.g. due to a bug, or a dropped message.
This is why we have SS session timeout, that prevents
keeping 'stalled' sessions forever.
Let's introduce a VTY option, which can be used to configure
this timer (by default it's set to 30 seconds):
hlr
...
! Use 0 to disable this timer
ncss-guard-timeout 30
Change-Id: I971fc2cee6fd46d4d5d6dac6c634e0b22fff183d
Related: OS#3717
There are some requests that are best served inside the HLR, as it
has access to subscriber information such as MSISDN and IMSI.
This unfortunately required quite some restructuring of the USSD
related structures including the VTY syntax for adding routes.
The default config file has been updated to replicate the *#100#
built-in behavior of old OsmoNITB.
Closes: OS#2566
Change-Id: I1d09fab810a6bb9ab02904de72dbc9e8a414f9f9
It is a global variable, and it's sort of bogus if every C file
re-declares it as a static global variable that is assigned to the
same value as the "real" global one during start-up.
Change-Id: I6f3e50f071fb2fbbe58413b4760dc2215055a444
vty_install_default() and install_default() will soon be deprecated.
Depends: I5021c64a787b63314e0f2f1cba0b8fc7bff4f09b
Change-Id: I09762f110c7bcaf85c0ef2f472eb43ac543c74e9
Implement VTY commands for subscriber manipulation:
- create / delete subscriber
- modify MSISDN
- add/edit/remove 2G and 3G authentication data
- show by IMSI, MSISDN or DB ID.
(enable/disable CS/PS and purge/unpurge to follow later.)
Implement VTY unit tests for the new commands using new
osmo_verify_transcript_vty.py from osmo-python-tests.
Depends: libosmocore I1e94f5b0717b947d2a7a7d36bacdf04a75cb3522
osmo-python-tests Id47331009910e651372b9c9c76e12f2e8964cc2c
Change-Id: I42b3b70a0439a8f2e4964d7cc31e593c1f0d7537
Add config file, mainly for logging control.
Open VTY on the OMSO_VTY_PORT_HLR added to libosmocore in
commit 92fa18e6b800a27aa064a5fb8321cddd7383ae20
aka change-id I08cb52d9399a27e6876e45da36f434708c4fddef.
Add hlr_vty.h/c for standard VTY setup.
Add -c option to pass config file.
Add --version option.
Change-Id: Iedb884345a597371a337b0c67eb6013b7d5d1ce1