Pau Espin 17f7c38755 sysmocom: emergency_preemptive_call.py: Avoid test failure if 2nd call not fully established
It may happen that the non-emergency call MT leg is still not properly
released when the emergency call MT leg is to be assigned a TCH, meaning
BSC will fail with an Assignment Failure upon Assignment request from
MSC.
The test sometimes passed and sometimes didn't, due to above mentioned
race condition. Let's relax a bit the test expectancies to have it
always passing, while still verifying preemption happens, and MT phone
is reached.

Related: OS#4549
Change-Id: I3697227cac56a1327f9ea08c5c2f52568e8d2a8a
2020-10-21 18:02:07 +02:00
Pau Espin 66c054288b sysmocom: Introduce test to verify emergency call preemption
Change-Id: I59993e65b3fd34fb2c3e5b002ab9666db9b7bad5
2020-10-15 19:02:27 +02:00
Pau Espin 680ba03038 sysmocom: Introduce suite to test emergency calls
Change-Id: I2e851c94311ded0abd4ff072b8cc72316d972750
2020-10-15 15:50:48 +00:00