The Siemens BS-11 supports the following additional GSM 12.21 OML operations:
CREATE OBJECT
abis_om_fom_hdr.obj_class can be
A3:
A5: ALCO, BBSIG, CCLK, GPSU, LI, PA
A8: EnvaBTSE
A9: BPORT
the abis_om_obj_inst.trx_nr field indicates the index of object, whereas the
abis_om_fom_hdr.bts_nr indicates the type of the object.
enum abis_bs11_objtype {
BS11_OBJ_ALCO = 0x01,
BS11_OBJ_BBSIG = 0x02, /* obj_class: 0,1 */
BS11_OBJ_TRX1 = 0x03, /* only DEACTIVATE TRX1 */
BS11_OBJ_CCLK = 0x04,
BS11_OBJ_GPSU = 0x06,
BS11_OBJ_LI = 0x07,
BS11_OBJ_PA = 0x09, /* obj_class: 0, 1*/
};
In case of CREATE ENVABTSE, the abis_om_obj_inst.trx_nr indicates the EnvaBTSEx
number.
In case of A9 (CREAETE BPORT), the abis_om_obj_inst.bts_nr indicates which BPORT
shall be used.