OsmoCC mISDN endpoint
Go to file
Dennis Grunert 4672e35a13 Fix: AOC-D unit information length; encode AOC-E according to real traces; Add option to disable seconds in time/date IE
- Fix: AOC-D unit information length was set to 1 despite its actual length
- Removed optional BillingID from AOC-E data
- Cross-checked AOC-D and AOC-E IEs to other systems (Audiocodes Mediant 800; traces found in public sources)
- Tested with ISDN TEs: Siemens Profiset 51, T-Concept P522, Philips SOPHO ErgoLine, sphairon NT1PLUS-split; K1297 ISDN protocol tester
- Attach AOC-E to DISCONNECT or RELEASE; transmit AOC-E even if zero units have been charged
- Send AOC-D with zero units to indicate free of charge call
- New option "time-no-seconds" disables sending current seconds within the date/time IE
2024-01-29 02:44:03 +01:00
m4 Add missing m4 directory 2021-03-20 07:23:31 +01:00
src Fix: AOC-D unit information length; encode AOC-E according to real traces; Add option to disable seconds in time/date IE 2024-01-29 02:44:03 +01:00
.gitignore Move from local to external osmo* libraries 2024-01-18 18:38:50 +01:00
LICENSE Add LICENSE file 2021-01-03 09:46:59 +01:00
Makefile.am Initial GIT import 2020-12-23 10:00:18 +01:00
configure.ac Move from local to external osmo* libraries 2024-01-18 18:38:50 +01:00
git-version-gen Initial GIT import 2020-12-23 10:00:18 +01:00