- Parameter "morsegerman" for option "local-tones" will generate morse-a dialtone (pre-1979).
- Fixed german tone pattern timings according to 1TR110-1 Chapter 8
* Busy tone: 480ms on / 480ms off
* Hangup tone: 480ms on / 480ms off
* Old german ringing: 1000ms on / 4000ms off
* Old german busy/hangup tone: 125ms on / 475ms off
- Fix: AOC-D unit information length was set to 1 despite its actual length
- Removed optional BillingID from AOC-E data
- Cross-checked AOC-D and AOC-E IEs to other systems (Audiocodes Mediant 800; traces found in public sources)
- Tested with ISDN TEs: Siemens Profiset 51, T-Concept P522, Philips SOPHO ErgoLine, sphairon NT1PLUS-split; K1297 ISDN protocol tester
- Attach AOC-E to DISCONNECT or RELEASE; transmit AOC-E even if zero units have been charged
- Send AOC-D with zero units to indicate free of charge call
- New option "time-no-seconds" disables sending current seconds within the date/time IE
If metering details via IE_METERING are received from osmo-cc, AOC-S and/or AOC-D facility IEs are attached to PROCEEDING/ALERTING/CONNECT messages, and AOC-D facility messages are generated during the call. This feature can be enabled by setting 'aocs' and/or 'aocd' within the mISDN endpoint configuration.
* Use raw bchannel instead of DSP feature
* Removed DSP features
* Use new jitter buffer and control TX FIFO load by this application
* Added bridging daemon to assign time slots for bridging