If metering details via IE_METERING are received from osmo-cc, AOC-S and/or AOC-D facility IEs are attached to PROCEEDING/ALERTING/CONNECT messages, and AOC-D facility messages are generated during the call. This feature can be enabled by setting 'aocs' and/or 'aocd' within the mISDN endpoint configuration.
Channel selection in that mode must be forced, so that the TE nay not
select a different channel. In that mode the TE cannot know what
channel is allocated, so it cannot select a different channel.
Eumex PBX rejects calls without this fix.
* Use raw bchannel instead of DSP feature
* Removed DSP features
* Use new jitter buffer and control TX FIFO load by this application
* Added bridging daemon to assign time slots for bridging
When (exclusive or suggested) channel is offered, we must "seize" it, so that
it is linked with call instance. Still the channel might be changed on reply.