Changed AOC-D encoding value of TypeOfChargingInfo from Total to SubTotal
encodeAOCDChargingUnitOperation() set the value of TypeOfChargingInfo to Total, which results in ISDN phones not correctly displaying increasing units. Setting it to SubTotal fixed the issue.
This commit is contained in:
parent
57896efb5f
commit
b7887e39cf
|
@ -406,7 +406,7 @@ static int encodeAOCDChargingUnitOperation(__u8 * dest, const struct asn1_parm *
|
|||
p[i++] = 0x30;
|
||||
p[i++] = (0x02 + len);
|
||||
p[i++] = 0x02; // Operation Tag
|
||||
p[i++] = 0x01; // AOC-D so Sub-Total
|
||||
p[i++] = 0x01;
|
||||
|
||||
// Recorded units could take up as much as 3 bytes (0xFFFFFF)
|
||||
p[i] = numberOfUnits & 0xFF;
|
||||
|
@ -416,9 +416,9 @@ static int encodeAOCDChargingUnitOperation(__u8 * dest, const struct asn1_parm *
|
|||
p[i+2] = (numberOfUnits >> 16) & 0xFF;
|
||||
i += len;
|
||||
|
||||
p[i++] = 0x82;
|
||||
p[i++] = 0x01;
|
||||
p[i++] = 0x82; // Type of charging info
|
||||
p[i++] = 0x01;
|
||||
p[i++] = 0x00; // AOC-D so Sub-Total
|
||||
|
||||
p[1] = (AOCD_CHARGE_UNIT_IE_LENGTH + len); // IE Payload Length
|
||||
p[4] = p[1] - 3; // Invoke Component Length
|
||||
|
|